Series AN silencers offer various styles and low back pressure in a compact, easy mounting design. The noise reduction has been improved to 30 dB(A) and the case is UL94-V0 grade, flame resistant material. Series AN is available with M, R or NPT threads.
Stations: 2 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Integrated Display, Return Unit Flow Range: 0.5 to 4 L/min, Return Unit Components: w/Flow Adj. Valve; Stop Valve: None, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: NPN
Stations: 10 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Integrated Display, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: NPN; Temp
Stations: 3 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Integrated Display, Return Unit Flow Range: 5 to 40 L/min, Return Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 3/4, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: NPN; Temp
Stations: 3 Stations, Supply/Return Unit Layout: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Integrated Display, Return Unit Flow Range: 5 to 40 L/min, Return Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 3/4, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
If a reference point sensor is required for use in conjunction with an LECS series motor driver, mount a separate sensor.
When using return to origin in conjunction with an LECP series controller or an LECPA series motor driver, as a pushing operation is used to return to origin, an origin sensor is not required.
Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style. Bar stock type manifold for VQZ100 base mounted valves; Maximum 20 stations available as standard; Side and top porting; Optional DIN rail mount; 8 port sizes
Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style. Bar stock type valve manifold for VQZ200/300 series valves; Optional DIN rail mount; Side porting; Maximum 20 stations available as standard; 12 port sizes available
Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style. Bar stock type manifold for VQZ100 base mounted valves; Maximum 20 stations available as standard; Side and top porting; Optional DIN rail mount; 8 port sizes
Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style. Bar stock type valve manifold for VQZ200/300 series valves; Optional DIN rail mount; Side porting; Maximum 20 stations available as standard; 12 port sizes available
However, as more than 40 years have elapsed since production started, we recommend switching to a VPA742-1-03*-F or VPA742-1-04*-F.
Note) The operating pressure range of VPA742 series valves is 0.2 to 1.0 MPa.
As for VSA4□20, VSA4□30, and VSA4□40 series valves, they are also still available and can be found in the web catalog.
Auto switches cannot be retrofitted without a magnet. If it is not a CDA2 series cylinder, the auto switch will not respond because there is no magnet inside.
Common special order options for tubing can be found here.
Details on specifications other than those shown below can be found on the page of each of tubing series. Reinforced corrugated cardboard
specification/Longer length reel:
https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=tubing&fa_id=11114
When temperatures are low, such as in winter, the viscosity of the hydraulic oil used may increase, and the differential pressure indication switch may mistakenly be activated.
In such cases, wait until the fluid temperature rises after it is warmed up, and reset the differential pressure indication switch before starting the main operation (20°C or higher is recommended).
Bore sizes: 20, 25, 32, 40, 50, 63, 80, 100 mm; Non-rotating accuracy ranges from +/-0.05° (100 mm bore) to +/- 0.09° (20 mm bore); Rubber bumpers as standard; Auto switch capable
Bore sizes: 20, 25, 32, 40, 50, 63, 80, 100 mm; Non-rotating accuracy ranges from +/-0.04° (100 mm bore) to +/- 0.07° (20 mm bore); Rubber bumpers as standard; Auto switch capable
Bore sizes: 20, 25, 32, 40, 50, 63, 80, 100 mm; Non-rotating accuracy ranges from +/-0.04° (100 mm bore) to +/- 0.07° (20 mm bore); Rubber bumpers as standard; Auto switch capable
Bore sizes: 20, 25, 32, 40, 50, 63, 80, 100 mm; Non-rotating accuracy ranges from +/-0.05° (100 mm bore) to +/- 0.09° (20 mm bore); Rubber bumpers as standard; Auto switch capable
(mm) Applicable cylinder bore size (mm) 4 6 8 10 12 AS-FPG AS-FPQ Clean performance Resin: PP Metal: Brass (electroless nickel plated) Resin: PP Metal: Stainless steel (SUS304) M5 x 0.8 6, 10, 16, 20 AS121FP-M5 R 1/8 20, 25, 32 AS221FP-01 R 1/4 20, 25, 32, 40 AS221FP-02 R 3/8 40, 50, 63 AS321FP-03 10-AS-F 10-AS-FG R 1/2 63, 80, 100 AS421FP-04 Resin: PBT, POM Metal: Brass (electroless nickel