SMC Corporation of America
Elite Part Number Search
Search Results "CH2FTC100B-800-G"

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: G, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: G, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: G, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: G, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: G, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: G, Auto Switches: Without auto switch,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: G, Auto Switches: Without auto switch

300 400 500 600 700 800 900 0 200 400 600 800 1000 1200 Speed: V [mm/s] Speed: V [mm/s] Servo Motor (24 VDC) The following graph shows the values when moving force is 250%.

Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end (mm/s) Speed at the end (mm/s) Applicable related components Applicable related components For details regarding different conditions, make determinations after using the SMC Model Selection Program Pneumatic Cylinder Drive Systems.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX DMounting height -X Reduction by 15 to 20% (Compared to SMC Series MGQ) 20Data Guide table Series MGF 40, 63, 100 Built-in non-rotating mechanism Internal guide pin prevents rotation.

Limit switch abnormality 4 314 11 Series LC6D/LC6C Options Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Caution Do not repeatedly apply bending stress or tension to the cables.

When the source pressure is 1700 psig (11.7 MPa), achievable delivery pressure is around 125 psig (0.86 MPa ) (HF and FC option 120 psig (0.83 MPa)). 2) 250 psig outlet pressure preset at 800 psig (5.5MPa) inlet pressure. Custom inlet/outlet pressure settings available.

Cooling Capacity HEC002 HEC006 Circulating fluid: Clear water Circulating fluid: Clear water 800 1400 700 1200 Ambient temperature: 59 (15C) 600 1000 Cooling capacity (W) Cooling capacity (W) Ambient temperature: 59F (15C) 500 HRG HRS HRZ HRZD HRW HEC HEB HED Technical Data Related Products 800 Ambient temperature: 68F (20C) 400 600 Ambient temperature: 77F (25C) 300 Ambient temperature:

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 8 Rc 3 position exhaust center 1 4 1 8 Rc 0.86 VR 1 8 Rc Note) The table shows the valve without sub-plate. With sub-plate: Add 0.24 kg VH Specifications Large flow capacity.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Characteristics: Quick response Long service life Compact Fig. (1) Equivalent circuit of a NPN type switch with the output off Fig. (2) shows an equivalent circuit of a NPN switch with the output on. In this circuit the load is powered.

If hunting is occurring, stop it controller. ) with a PID adjustment (parameter code: 800). See Improved Controllability.

Bore size 32 mm 32 40 mm 40 50 mm 50 63 mm 63 Action Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Double acting D Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.

Description Long 500 420 3 0.52 to 1.63 80 160 IF32 IF31 IF30 Long 1,000 800 4 0.61 to 1.91 160 320 Cover q SPCD SPCD 12 ADC Mounting plate SPCC Stainless steel 304 Stainless steel 304 w Long 1,800 1,450 5 0.69 to 2.23 280 560 Bellows e r PBP or Stainless steel 304 Long 2,600 2,000 6 0.70 to 2.28 400 800 Body C3604B or Stainless steel 304 ON-flow: Flow volume under which a microswitch starts

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Due to its small size, the sensor can be installed close to a pad.