Rated Flow Range: 0.05 to 5 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: w/o Lead Wire w/Connector, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: w/o Lead Wire w/Connector, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: 1/4, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: w/o Lead Wire w/Connector, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø6, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: w/o Lead Wire w/Connector, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: w/o Lead Wire w/Connector, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 1 to 100 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: 1/4, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: w/o Lead Wire w/Connector, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Body Size: 30, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 03 (3/8), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X102 (Hub and Relief Valve only)
Body Size: 30, Thread: F (G), Port: 03 (3/8), Option: C [Float Type Auto Drain (N.C.)], Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 30, Thread: G, Port: 3/8, Option: C [Float Type Auto Drain (N.C.)], Attachment: Residual Pressure Relief 3 Port Valve, Semi-Standard 1: Metal Bowl, Semi-Standard 2: Standard
Body Size: -, Thread: -, Port Size: -, Option: -, Attachment: -, Semi-Standard 1: -, Semi-Standard 2: -
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: C (N.C. Float Type Auto Drain), Attachment: S (Pressure Switch), Semi-Standard 1: Standard, Semi-Standard 2: N (Non-Relieving Exhaust Mechanism)
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: C (N.C. Float Type Auto Drain), Attachment: SV (S + V), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: N (Non-Relieving Exhaust Mechanism)
Body Size: 30, Thread: G, Port Size: 3/8, Option: N.C. Float Type Auto Drain, Attachment: Pressure Switch, Semi-Standard 1: Standard, Semi-Standard 2: Non-Relieving Exhaust Mechanism
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: Â
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N2 (NPT1/4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)