SMC Corporation of America
Elite Part Number Search
Search Results "VV5FS5-10-021-06"

method Heating type sensor (branch flow type) Rated flow range 10 to 1000 L/min 20 to 2000 L/min Instantaneous flow 10 to 1050 L/min 20 to 2100 L/min Set point range Accumulated flow 0 to 999,999,999,990 L Flow specifications Instantaneous flow 1 L/min 2 L/min Minimum resolution Accumulated flow 10 L Accumulated volume per pulse (Pulse width = 50 msec.)

L1 E1 R1 U1 A1 U1 R1 A MM NDH10 NZ MM NDH10 NX NX E1 L1 30 40 50 60 60 20 22 28 40 40 12 12.5 16.5 23.5 23.5 16 19 24 34 34 32 40 50, 63 80 100 32 40 50, 63 80 100 14 19 24 26 26 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 M10x1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20

KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-12 16 4 32 6 18 6 35 8 20.5 8 39 10 Series SY3000 SY5000 SY7000 Part No. 22 10 43 12 SY3000-52-2A 24 12 45.5 14 SY5000-52-2A SY3000/5000 DIN rail dimensions and weight SY7000-52-2A VZ1000-11-1Blocking disk indication stickers Refer to L dimensions Enter a number from the DIN rail dimension table below in the .

V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PFMC7501 5 L/min 500 L/min PFMC7102 10 L/min 1000 L/min PFMC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.

V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PF2MC7501 5 L/min 500 L/min PF2MC7102 10 L/min 1000 L/min PF2MC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.

-01 G43-2-01 G43-4-01 G43-10-01 G43-10-01 G43-4-01 G43-10-01 Accuracy + 3% (full span) Courtesy of Steven Engineering, Inc. !

(mm) Model Applicable tubing M Weight (g) Applicable fitting size d Note) L A D KRR06-08 8 39.5 37 2.5 6 12.8 17 18.5 10.4 5.6 KRR06-10 10 4.0 9.3 KRR08-10 10 18.5 42 20 23 15.2 41 18.5 26.1 18.0 8 KRR08-12 12 4.6 33 KRR10-12 10 12 18.5 44.5 21 41.5 32.8 Applicable fitting size d Note) D: Max. diameter K Bulkhead Union: KRE M Effective area (mm 2) FR soft nylon FR double layer Applicable

Refer to the table for each pressure specification (page 110) Display/set pressure range Display/min. setting unit Power supply Used as switch output device 12 to 24 VDC (10%), and voltage ripple (p-p) 10% at max. voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Electric spec. Power supply voltage 12 to 24 VDC (10%), and ripple (p-p) 10% at max.

Auto Switch l1 50 Safety distance (mm) 40 Operational range 30 l1 20 l1 Dangerous range 10 0 5000 10 15000 20 Welding current (A) l2 50 40 Safety distance (mm) 30 l2 l2 Operational range 20 10 0 5000 10 15000 20 Welding current (A) 1340

DIN Rail Manifold Common SUP/Common EXH How to Order Type 45 (Non plug-in type) Applicable solenoid valve C D 45 05 C8 VV5Z5 G L M D VZ54Stations 4 (A), 2 (B) port size SUP/EXH block mounting position 02 2 stations Applicable blanking plate assembly VZ5000-65-2A One-touch fitting for 6 Symbol Position Applicable stations 2 to 10 stations D U C6 20 20 stations B 2 to 20 stations 2 to 10

50 Safety distance (mm) 40 Operational range 30 l1 20 l1 Dangerous range 10 0 5000 10 15000 20 Welding current (A) l2 50 Safety distance (mm) 40 30 l2 l2 Operational range 20 10 0 5000 10 15000 20 Welding current (A) 32 SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE SPAIN/PORTUGAL SMC Espaa, S.A.

PLC H.T. ) Enable 1 (SC_MonSs) Disable -10..10 V -5..5 V -20..20 mA 0..10 V 2 (Range) -10..10 V 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary PLC 3 (D_Format) Sign & Magnitude 2S Complement None 2 2AVG 2 4 (Filter) 4AVG 4 8AVG 8 Enable 0.5 5 (Over_Rng) Disable Enable 0.5 6 (Undr_Rng) Disable Enable 1 (Upr_Lmt) 7 Disable Enable 1 (Lwr_Lmt) 8 Disable

Air Fluid Operating pressure range (MPa) 0.15 to 0.7 Internal pilot Ambient and fluid temperature (C) Response time (ms) (at the pressure of 0.5 MPa) (1) 10 to 50 (No freezing. Refer to page 4-18-4.) 20 or less Max. operating frequency (Hz) 10 Flow characteristics Refer to the table below.

Table 1 Display Real-time flow rate l/min Accumulated flow l, m, m x 10 ft, ft x 10, ft x 10 CFM Note 1) For the type with unit switching function [The type without the unit switching function will have a fixed SI unit (l/min, or l, m or m x 10)]. 14 For Air Digital Flow Switch Series PFA 4. Output Specification Selection Mode For For Flow rate setting SET SET Press the SET button.

-5 Gasket DXT192-10-5 (Use caution to the orientation.)

(mm) 02 04 2 4 Nil -X19 With lock ring Without lock ring (10 or larger) 1 2 10 to 16 20 to 32 ZX 06 6 3 40, 50 ZR 08 8 Material 10 10 ZM N S NBR Silicon rubber 13 13 16 16 Pad type U Urethane rubber 20 20 ZH F Fluoro rubber 25 25 U C Flat Flat with ribs GN Conductive NBR (2 to 16) 32 32 ZU GS Conductive silicon rubber (2 to 16) 40 40 D Deep 20 or large are manufactured upon receipt of order

UT ZPT10UT-A6 4 4 4 4 ZP10UT ZP 13 UT ZPT13UT-A6 4 4 4 4 ZP13UT ZP 16 UT ZPT16UT-A6 4 4 4 4 ZP16UT ZP 10 U ZPG10U-7A-X2 7 7 7 7 ZP10U ZPT2-7A-X2 ZP 13 U ZPG13U-7A-X2 7 7 7 8 ZP13U ZP 16 U ZPG16U-7A-X2 7 7 7 8 ZP16U ZP 20 U ZPG20U-7A-X2 9 10 10 10 ZP20U ZPT3-7A-X2 ZP 25 U ZPG25U-7A-X2 10 10 10 11 ZP25U ZP 32 U ZPG32U-7A-X2 10 11 11 12 ZP32U ZP 10 C ZPG10C-7A-X2 7 7 7 7 ZP10C ZPT2