Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, FLOW CONTROL, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, AB, AS***F M5 STANDARD (PT), .56830 lb

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FSM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: E (8mm), Tube Size: 02 (ø2)

close proximity with each other either horizontally or vertically Plug connection ower supply output connection 30 e-Con connector Analog output or auto shift input 2 outputs + Sensor connection M5 female thread, through type (with mounting holes) M3 M5 female thread, through type M5 6 reducer 4 reducer R1/8,NPT1/8 Applications Manifolding is possible.

AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12

B 0 Normally Closed/Single unit Electrical option Nil None Port size S With surge voltage suppressor L With indicator light 02 03 04 Rc 1/4 Rc 3/8 Rc 1/2 With light/surge voltage suppressor Z Refer to the table (1) given below for availability.

I ~J' 20 24.5 zs -~ -eli Bracket View A Panel Mount Type Side dimensions for 418 panel mount type 0 40 21.2 , 6 8.5 36.0-5 >, D 0 . 1,16o;~1 ~ \ z 5-22-0 1 ZS-22-02 Thickness of the panel is 1 to 3.2mm. Panel mount adaptor A Panel mount adaptor B SMC CORPORATION 1-16-4 Shrmbashi. Mlnalo-kv.

size 20 30 40 50 60 AFF Nominal filtration rating: 1 m V V V V V Water droplet removal ratio: 99% AM Nominal filtration rating: 0.1 m V V V V V Oil mist concentration on the outlet side: 1 mg/m3 q Filter type AMD Nominal filtration rating: 0.01 m V V V V V Oil mist concentration on the outlet side: 0.1 mg/m3 + e Thread type Nil Rc V V V V V N*1 NPT V V V V V F*2 G V V V V V + 01 1/8 V 02

Table 3.3-1 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker Terminal Power Recommended Cable Sensitivity block Model supply crimp Specifications Breaker of screw voltage terminal 1 size leakage diameter (A) current (mA) 4 cores x AWG10 (4 cores x 5.5 mm2) HRL100-A-20 3-phase R5.5-5 30 200V AC including (50Hz) ground M5 30 4 cores x 3-phase HRL200-A-20 40 AWG8

Table 3.3-1 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker Terminal Power Recommended Cable Sensitivity block Model supply crimp Specifications Breaker of screw voltage terminal 1 size leakage diameter (A) current (mA) 4 cores x AWG10 HRL100-A-20 3-phase (4 cores x 5.5 mm2) R5.5-5 30 200V AC including (50Hz) ground M5 30 4 cores x 3-phase HRL200-A-20 40 AWG8

Table 3-3 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker *1 Terminal Cable Model Power supply block Recommended Sensitivity specifications Rated voltage screw crimp terminal of leakage *2 current diameter current (A) (mA) 380-415 VAC 4 x 5.5 mm2 50/60Hz 3 phase, (4 x AWG10) HRS200-A-46-S M5 R5.5-5 30 30 *Including 460-480 VAC 60Hz ground 3 phase *1.

45) 01-r,6NPr 02-TNPI 03-Stl.lPI 04_I'NPI N Pon thrEd Fluoro rubber E Fluororesin lining Fluoro rubber Fluoro rubber & Fluoro resin lining Port lhrad N-NPT F-PF _-Rc(Pn' *Special o.der only.

Rc NPT G Symbol N M12 3 m lead wire with connector Without lead wire Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Port size Output specification Port size Applicable model Flow rate (l/min) Symbol Symbol Output specification 100 200 500 50 10 01 02 03 04 1/8 1/4 3/8 1/2 27 NPN open collector 2 outputs PF2A710/750 PF2A711/721 PF2A751 67 PNP open collector 2 outputs

Wiring specification Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Rc NPT G Nil N F 3m lead wire with connector Without lead wire Nil N Output specification Port size Size Applicable model Flow rate (l/min) Nil Output specification Applicable model Symbol 10 50 100 200 500 PFA710, 750 PFA711, 721, 751 PFA711, 721, 751 NPN open collector 2 outputs 27 1/8 1/4 3/8 1/2 01 02

AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12

2 VX3 ) VXA How to Order VN VXH2230 02 1 G LVC LVA Bracket Nil B 3 -B JIS Symbol LVH LVD Valve/Body 0 3 ' +0 Electrical option Nil 3 LVQ S ( L LQ Z + ( Port size 6 ( 2 (-' LVN 02 03 04 6 +" 6 &+$ 6 +! TI/ TIL Electrical entry G 8 PA Rated voltage C ) 2 ! >) +# = 1 >) +# = D 543 PAX T ) 3 >) +# = 6 ( 4 !! >) +# = PB 7 !"

Fluoro rubber is used for the rubber parts of seals How to Order Manifolds -lI O Ozone resistant specifications ilTv2o port size EI 114 {xt 3/8 type How to Order Manifold Assemblies shtionu "o,.,) llTV20-02-3. lset (3 station manifold base part no.) lTV2030-312S-X26 . . .. .. . . l set (Electro-pneumatic regulator part no.)

No Thread IMPERIAL Code : Thread Form 00 : None (No reduction in METRIC Code : Thread Form METRIC Code : Thread Form Code : Thread Form 27 : 3/4-10 60 : M3 x 0.35 88 : M14 x 1.5 piston rod diameter) 28 : 3/4-16 61 : M3 x 0.5 89 : M20 x 1.5 01 : 2-56 29 : 7/8-9 62 : M4 x 0.5 90 : M12 x 1.25 02 : 2-64 30 : 7/8-14 63 : M4 x 0.7 91 : M42 x 1.5 03 : 4-40 31 : 1-8 64 : M5 x 0.5 92 : M24 x 3.0 04

NT-02 NT-03 NT-04 13 5 15.0 12.5 M8 x 1.25 17 6 19.6 16.5 M10 x 1.25 22 8 25.4 21.0 M14 x 1.5 Mounting Nut Applicable pin part no. Part no.

Example) AR30K-03BE-1NR-B w e V q Body size 20 25 30 40 50 60 Symbol Description V w With backflow function Nil Without backflow function K Note 1) With backflow function + V e Pipe thread type Nil Rc N NPT F G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 V r Port size + a Mounting Nil Without mounting option B Note 3) With bracket H With set nut (for panel mount) + Nil Without pressure

The connection may be a 1/8 inch NPT female thread or 10-32 female thread or M5 depending on the valve model. 3. After installation, check internal leakage (leakage across seat) with inert gases. Perform a helium leak test depending on applications. Maintenance Warning 1. If a valve requires repair, contact SMC. Operation (Air operate type) Warning 1.