(inch) 1 8 1 2 3 8 5 32 3 16 5 16 1 4 One-touch Inch-size tubing/UNF, NPT thread connection Possible to use in vacuum to 100kPa UNF 10-32 Nylon 1 16 One-touch Mini Series KJ Soft nylon 1 8 Polyurethane Unions Applicable area U.S.A. etc.
VNH1 VNH2 VNH3 VNH4 VNH1-16 VNH2-16 VNH3-16 VNH4-16 Description 3 Note 2) 2 1 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz Bracket (With bolt and washer) B 4 Note 2) How to Order Pilot Solenoid Valves 5 24 VDC 7 Note 2) 6 Note 2) 12 VDC CE compliant VO307 Q 240 VAC 50/60 Hz Note) Electrical entry: D or DZ only Other 9 Note 2) Note 1) Electrical entry: D or DZ only Note
18 Line 19 OFF() () -74No.PS-OMV0008CN-E 16 16 16 Line 1 (11seg) 16 16 16 Line 24 (7seg) -75No.PS-OMV0008CN-E , (1015 ) -76No.PS-OMV0008CN-E ,, (), No.1 ON ON OFF Yes No.2 No OFF ON No.1 OFF No.3 No.4 No.5 No.6 -77No.PS-OMV0008CN-E No.7 No.8 No.8 No.9 No.10 No.11 No.12 No.13 No.14 -78No.PS-OMV0008CN-E No.
) (67) (73) Pilot port threaded type 20 39 30 A A 32 2 x 5 MAX 14 (52.6) M5 x 0.8 Depth 5 Pilot port M5 x 0.8 Depth 5 Pilot port 44 36.5 23.5 1/8 1/8 9.5 (41) 4.5 (67) 501 Tube Extensions Series LVD How to Order Body class LVD 2 0 06 T Option Symbol 2 3 4 5 None With flow rate adjustment Nil 1 Orifice dia. 4 8 10 16 Body class 2 3 4 5 Note) Refer to Variations in the table below for option
Date and time, Operation time and Alarm history are not reset. (1) Data reset setting screen Table 5.4-16 Data reset setting No.
M6x1 11 54 6.5 M6x1 12 84 32 15 M8x1.25 14 64 8.5 M8x1.25 12 102 41.5 19 M10x1.5 R S T U V W X Y Z 22 63.5 23.5 22 41 16 9 30 34.5 26 77.5 32.5 27 56 19 10 37 42 37.5 95 50.5 35 68 23 23 45 51 I J K L M N O P Q 76.5 40 46 28 11 14.5 28 15 16 91 46.5 58 32 15 16 30.5 16 21.5 110 55 68 36 16.5 22 37.5 17.5 24.5 A B C D E F G H ML2B25 110 220 206 42 138 93.5 16 73 ML2B32 140 280 264 51 168
47 49 61 63 69 74 73 78 95 100 Dimension with cover Reference dimension of NPT thread after installation. 1/4" 5/16" 1/4" 5/16" 5/16" 3/16" 5/16" 3/16" 5/16" 3/16" 3/16" 1/2" 3/16" 1/2" 3/16" 1/2" 12.7 NPT 1/8 23.4 27.4 39.8 45.8 17.6 14.3 NPT 1/4 25.4 31.4 39.8 45.8 17.6 12.7 NPT 1/8 26.7 30.7 45.3 52.8 24.4 14.3 NPT 1/4 28.7 34.7 45.3 52.8 24.4 17.5 NPT 3/8 30.4 36.7 45.3 52.8 24.4 17.5
A D1 D2 L Nylon Urethane KSH03-34S KSH03-32 8 10-32 UNF 9 14 17 23 23 29 55 63 36.5 33 38.5 34.5 39.5 35.5 42.5 36.5 44 40 47 41 54 48 55 48.5 5 32 16 2.5 10.4 4.0 4.0 12 1 8 12.7 1 8 1 4 KSH07-34S 14.29 17 1 4 4 13.4 10.4 13.2 14 KSH07-35S KSH09-34S KSH09-35S KSH11-35S KSH11-36S 1 8 18.5 5 16 1 4 1 4 3 8 6 26.1 18.0 15.2 17.46 17 22.23 3 8 7 36.3 29.5 17.9 22 21 Reference dimensions after
Valve diagnostics 2 If the maximum number of valves is 16 coils in the EX245-SPN1/SPN2, the diagnostics will be set FFh.
MGPWM Common Dimensions (mm) A E Standard stroke (mm) Bore size (mm) B C DA DB FA FB G GA GB H J K L 50 st or less Over 50 stroke 50 st or less Over 50 stroke 20 25 32 40 50 63 44.5 47 52 56 60.5 67.5 34 35 37 41 42 49 10 10 14 14 18 18 10 12 16 16 20 20 7.5 9 10 10 12.5 12.5 3 3 5 5 6 6 36 42 48 54 64 78 9.9 10.3 11.4 13.5 14 15.5 7.5 8.7 9 10.5 11.1 13.5 137 157 190 206 258 286 18 21 24
47 49 61 63 69 74 73 78 95 100 Dimension with cover Reference dimension of NPT thread after installation. 1/4" 5/16" 1/4" 5/16" 5/16" 3/16" 5/16" 3/16" 5/16" 3/16" 3/16" 1/2" 3/16" 1/2" 3/16" 1/2" 12.7 NPT 1/8 23.4 27.4 39.8 45.8 17.6 14.3 NPT 1/4 25.4 31.4 39.8 45.8 17.6 12.7 NPT 1/8 26.7 30.7 45.3 52.8 24.4 14.3 NPT 1/4 28.7 34.7 45.3 52.8 24.4 17.5 NPT 3/8 30.4 36.7 45.3 52.8 24.4 17.5
Please contact SMC for more information. 16-3-41 10 Series PSE300 Functions I Anti-chattering function A large bore cylinder or ejector consumes a large volume of air in operation and may experience a temporary drop in the supply pressure. This function prevents detection of such temporary drops in the supply pressure as an error.
Contents 10 MXP10-PS 12 2 pieces of No.19 MXP12-PS 16 MXP16-PS MXPJ6 Description Material Note Parts list No.
Without auto switch (Without built-in magnet) Remarks Symbol Heater Temperature 16 D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Nil H0 H4 H5 5 to 60C None None With 100C heater With 120C heater Solid state auto switch 5 to 150C Reed auto switch (Not applicable to flange size 16) Note) Size 16 is not
Peak/ Bottom value reset: A function to clear the peak value or bottom value when an external input signal is applied. 41 No.PF-OMU0002-D
Applications Applications Drive motor Drive motor Drive motor Drive (Spool) Flexible Coupling Flexible Coupling Drive Body Piping Support Rotary joint Fixed (Body) Direction of rotation Fixed (Adapter plate) Rotary Joint Rotary joint (1 circuit) Flange Air gripper Example of 1 circuit Example of spool drive Example of body drive Made to Order Made to Order Operating temperature 40 to 100C 16
11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 VCB41 30 50 94 1/2 41 13.5 17 36 25 23 M5 8 26 88 48 78.5 103 78.5 70 111.5 35 60 102 3/4 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 17-2-27
90 45 8 22 107 70 74.5 103 74.5 48 84 26 1/4, 3/8 VCB41 M5 23 25 36 17 13.5 41 94 50 8 30 111.5 70 78.5 103 78.5 48 88 26 1/2 M5 28.2 30 36 17 17.5 41 102 60 8 35 119 70 86.5 103 86.5 48 96 26 3/4 4 Series VCB Model Selection VCB (for heated water) 2 port solenoid valve Class Orifice size mm Model Material Port size Body Seal 4 3 2 7 5 10 1/8 (6A) 2 1/4 (8A) VCB (for heated water) 2 port
11 17 36 22.5 23 M5 8 1/4, 3/8 VCL41 111.5 26 26.5 66.5 48 64.5 62 62 50.5 103 64.5 70 30 50 93.5 41 13.5 17 36 25 23 M5 8 1/2 119 26 26.5 70 48 68 62 65.5 50.5 103 68 70 35 60 101 41 17.5 17 36 30 28.2 M5 8 3/4 Note) For class H 4 Direct Operated 2 Port for Oil Series VCL How to Order Manifolds How to Order Manifold Assemblies (Example) VV2C L 2 02 01 Enter the valve and option models
Conditi on Inlet Air Temperature 100 F (37.8C) Ambient Temperature 100 F (37.8C) Voltage 115V 60Hz Working Fluid Compressed Air Operating Range Inlet Air Temperature 41-122 F (5-50C) MIN.