SMC Corporation of America
Elite Part Number Search
Search Results "RZQA32TN-100-40-M9PSAPC"

Standard Strokes Bore size (mm) 20 32 40 50 63 80 100 Standard strokes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic Fluid Compatibility 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic fluid Compatibility

The result is approximately 50l/min. 100 50 1 0 2 3 4 5 6 7 Cycle (Hz) Viscosity characteristics (flow rate correction for viscous fluids) Caution 100 1. These flow rate characteristics are for fresh water (viscosity 1mPas, specific gravity 1.0). 2.

The result is approximately 50l/min. 100 50 1 0 2 3 4 5 6 7 Cycle (Hz) Viscosity characteristics (flow rate correction for viscous fluids) Caution 100 1. These flow rate characteristics are for fresh water (viscosity 1mPas, specific gravity 1.0). 2.

Model ZK2-ZSV-A Rated pressure range -100 to 100 kPa Set/Display pressure range -105 to 105 kPa Proof pressure 500 kPa Minimum setting unit 0.1 kPa 12 to 24 VDC 10%, Ripple (P-P) 10% or less Power supply voltage (Protected against reverse connection) Current consumption 40 mA or less NPN or PNP open collector Output type OUT1: General purpose, OUT2: Valve control Maximum load current 80 mA

69 96 H P.C.D L1 6-4.4 6-6.6 8-8.4 L2 XMA-16 XMA-25 XMA-40 XMA-50 XMA-63 XMA-80 40 50 65 70 88 90 P.C.D 27 P.C.D 58.7 P.C.D 92.1 XYA/In-line type C D G Fd C (K flange) B H 45 A E Fn (KF flange) (mm) Model A 79.5 106 119 149 178 B 48 66 79 100 117 C 1 2 2 3 3 D 23.5 38 53 61 80 E 40 55 75 87 114 Fn 95 110 Fd 26 41 52 70 83 G 64 84 95 118 142 H XYA-25 XYA-40 XYA-50 XYA-63 XYA-80 100.2

(t{odel} Bore Sire (nnl {r) Skote (nn) lilodel WeigIt (sl Ixtended (lt) (omprer:ed (r{) HPt tolh[/tt(-l l 4 40 4.0-6.0 190 75,000 i,500 l 8 2:100 454 HPt toiltt/MC-2 t4 40 2.n-4,5 190 75,000 7,500 t 8 49 2,200 454 HPt toilI/|[c-3 14 40 0.i5-3.0 t90 75,000 7,500 t 8 49 L2n0 454 Itrq Itr. l{n/[our Itr) llox, l{m/ry(le Ai dirnensions n milimeterc. (ololog No.

Note: Monosashi-kun with Brake (CE2)s bore size setting Blinking 63 80 100 25 32 40 50 DOWN UP range from 40 to 100. After setting of cylinder bore size, press WRITE to switch to the next input condition. The display will indicate PRG STEP P5 and the current load rate, which is blinking. Next, enter correct load rate.

[C] [60 Hz] 0 10 20 30 40 50 Circulating fluid temperature [C] HRS018-A-10/HRS018-W-10 (Single-phase 100/115 VAC) 2500 2500 25C Cooling capacity [W] Cooling capacity [W] 25C 2000 2000 32C 1500 1500 32C 40C 1000 1000 40C 500 500 Ambient temperature or facility water temperature Ambient temperature or facility water temperature 0 0 [50 Hz] 0 10 20 30 40 50 Circulating fluid temperature [C]

MXQ16B 20.6 20.6 20.6 20.6 20.6 20.6 20.6 20.6 20.6 33 23 23 23 29 38 63 63 63 MXQ20B 32.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2 30.9 31.9 31.9 31.9 44.9 44.9 46.9 69.9 69.9 D-M9V/M9WV A 10 20 30 40 50 75 100 125 150 10 20 30 40 50 75 100 125 150 MXQ6(A) 18 7.4 7.4 7.4 7.4 2 2.6 5.6 7.6 7.6 MXQ8(A,C) 13.9 13.9 13.9 13.9 13.9 13.9 7.1 7.1 7.1 13.1 30.1 7.1 MXQ12(A,C) 16.5 16.5 16.5 16.5

Valve model Port size VCL2l VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCL3l VCW30-12-04A 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCL4l VCW30-12-04A 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 Mounting screws (for mounting bracket) are included

] 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100 140 180 220 260 300 130 Suction flow rate [l/min(ANR)] Suction Flow rate [l/min (ANR)] Time to reach vacuum Time to reach vacuum Measurement conditions/Tank capacity: 1l Supply pressure: 0.4MPa Measurement conditions/Tank capacity: 1l Supply pressure: 0.4MPa 100 90 100 90 Vacuum pressure

Model determination 2 Sine Rodless Cylinder Series REA Model Selection Method 2 Precautions on Design 1 Selection Method 40 32 25 500 500 300 200 300 400 Recommended driving force: Fn(N) 200 300 Recommended driving force: Fn(N) Recommended driving force: Fn(N) 200 100 100 100 50 40 20 30 40 50 20 30 40 50 20 30 Usable

30 Set pressure (kPa) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 100 0 20 40 60 80 100 120 57.0 100 95 90 85 80 75 70 65 60 Flow rate (l/min (ANR)) VAC side pressure (kPa) IRV3000 IRV3000 0 53.0 10 53.5 20 54.0 SET side pressure (kPa) 30 Set pressure (kPa) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 57.0 100 95 90 85 80 75 70 65 60 100 0 20 40 60 80 100 120 140 160 VAC

fluid outlet 0.6 60 Pressure [MPa] 0.5 50 Lifting head [m] Usable flow rate range 0.4 40 0.3 30 Circulating fluid return 0.2 20 0.1 10 0 0 0 20 40 60 80 100 120 140 160 180 Circulating fluid flow[L/min] Fig. 8-11 Pump capacity(HRL300-A-20 CH1) 8.5.4 HRL-A-20CH2 0.6 60 0.5 50 Lifting head [m] Pressure [MPa] 0.4 40 Usable flow rate range Circulating fluid outlet 0.3 30 0.2 20 Chiller display

switches S n 25 32 40 25mm 32mm 40mm 2 1 n Standard stroke Bore size (mm) Max. stroke (mm) Standard stroke* (mm) 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 25 32 40 2000 2000 2000 *When the required stroke is longer than the standard stroke , refer to the specifications for Made to

When movement starts again from the pushing stopped state, the pushing operation is repeated with the normal pushing force. 0B INP (Example) Step data force is 100% Step data Trigger LV is 80% The energy saving setting of the electric actuator is 40% *1) INP [ON] Force () 100 Trigger LV 80 Power saving mode 40 Time *1) The electric actuator model determines the energy settings.

Operation 32 C96N32-PS 17 Rod seal 1 pc 40 Rod seal 1 pc 41 Piston seal 1 pc 42 Large cushion seal 2 pcs 43 Small cushion seal 1 pcs 45 Cylinder tube gasket 2 pcs 40 C96N40-PS 50 C96N50-PS 63 C96N63-PS 80 C96N80-PS 100 C96N100-PS Lock part is replaced as an entire unit. The seal kit for replacement contains the rod seal for the cylinder and lock.

MGQ 12, 16 M L 10, 20, 30, 40, 50, 75, 100 20, 30, 40, 50, 75, 100 125, 150, 175, 200 M L MGQ 20, 25 MGJ MGQ 32, 40 50, 63 80, 100 25, 50, 75, 100, 125 150, 175, 200 M L MGP MGQ OUT(N) IN(N) Theoretical Output (N) Bore size (mm) MGG Operating pressure (MPa) Rod size (mm) Piston area (mm2) Operating direction 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 MGC Made to Order Specifications (For details

Standard Strokes Bore size [mm] Standard stroke [mm] 12, 16 10, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250 20, 25 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 32 to 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 Made to Order: Individual Specications (For details, refer to page 491.)

Symbol Note 1) Drain guide is NPT1/4 (applicable to AW30 to 40) Note 2) Drain guide is G1/4 (applicable to AW30 to 40). 20 30 40 30 40 01 02 03 04 06 1/8 1/4 3/8 1/2 3/4 02 03 04 06 1/4 3/8 1/2 3/4 Option Note 3) Option Note 3) Description With bracket Applicable model AW30, 40 AW30, 40 AW30, 40 Symbol Nil B G Note 4) H Description With bracket Applicable model AW20 to 40 AW20 to 40 AW20