[F_3] Copy function OFF Selection of output mode [o10] Instantaneous output mode Common Hysteresis mode 2 Indicator LED (output) Indicates the switch output status. LED is ON when the output is ON.
Note 3) For wear ring A of 10, please consult with SMC. 111 Magnetically Coupled Rodless Cylinder/Direct Mount Type: Centralized Piping Type Series CY3R 6, 10, 15, 20 25, 32, 40, 50 63 Replacement Procedure is P.316 Construction Centralized piping type CY3RG10 @9 @6 @4 @5 #0 @8 @7 CY3RG15 to 63 @4 @9 @6 #0 @5 @8 @7 The numbers are the same as the "Construction" of the Best Pneumatics No.2
Note 2) When more than one specification is required, indicate in ascending alphanumeric order. Note 1) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of 0.2MPa or more. Note 2) For M5 and NPT thread types. Under the New Measurement Law, the product is only sold outside Japan.
There is the internal stop in the handle or in the valve body. Rotate the handle clockwise until the internal stop is reached and it completely stops. 2. When opening the valve, rotate the handle counterclockwise until it completely stops. There is the internal stop in the handle. Rotate the handle counterclockwise until the internal stop is reached and it completely stops. 3.
Circuit (of class 2) which is of maximum 30 Vrms (42.4 V peak), with UL 1310 class 2 power supply unit or UL 1585 class 2 transformer. The product is a approved product only if it has a mark on the body. Press the button once to decrease by one digit, press and hold to continuously decrease.
When the and are pressed for 6 s. or more with the power supply on, the displayed value is reset to zero, and then the measuring mode is recovered automatically. Once the power supply is turned off, the offset value for zero clear is cleared. LR6 dry cell battery (2 pcs.) Safety Instructions 6 s.
Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 2) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.
Rotating Torque/Allowable Number of Rotations 5 32 1 4 5 16 3 8 " " " 0.012 8.3 0.014 6.7 0.020 5 Rotating torque (Nm) (2) Allowable number of rotations (S-1) (3) Applicable tubing O.D. " 0.006 8.3 Note 2) Rotating torque under pressure 0.5 MPa Note 3) Do not use the fittings with a leak tester or for vacuum retention because they are not guaranteed for zero leakage.
Particle diameter Adsorption surface size A B C Standard (0.3) 1 2 3 4 5 6 50 x 50 mm 100 x 100 mm 150 x 150 mm 200 x 200 mm 250 x 250 mm 300 x 300 mm 0.2 0.4 When particle diameter and port position are both standard, neither of them are specified.
32 to 140F (5 to 60C) Ambient and fluid temperature Accepts Many Types of Plastic Tubing 1 8 M3, M5, R(PT) Port size JIS B 0209 Class 2 (Metric coarse thread), JIS B 0203 (Taper pipe thread) Thread Hose nipple and hose elbow accepts nylon, soft nylon, and polyurethane tubing.
For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ6. CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34 (35.5) 3.5 (2) 24 (25.5) 6.5 (8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection.
4 OUT1 4 OUT1 Black 1: This setting is only abailable for models with the unit selection function. 2: When 2 outputs type is selected.
Note 2) Compared with standard specifications, its adjusting spring has only been changed. It is not the product which does not allow the pressure more than 0.2 MPa. Adjusting spring is not replaceable.
Flow Sensor Operation Manual Piping Internal circuit and wiring example Summary of Product parts Output for PF2D3 + Analogue (1 to 5 V) type: PF2D5 -1 Use the product within the specified operating pressure range and temperature range. Proof pressure is 1.5 MPa for PF2D504/520 and 0.9 MPa for PF2D540. Proof pressure could vary according to the fluid temperature.
Do not use it in a line that is kept pressurized because it could cause the body to break. 13-10-5 3 Series ZFB Dimensions Element Replacement 1. Stop the operation and reduce the internal pressure of the filter to atmospheric pressure. 2.
For type R, U, DC voltage is only available. Power saving circuit is only available in the "Z" type. DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Bracket Nil: Without bracket F: With bracket AC (50/60 Hz) 3 port 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, DC voltage is only available.
17.2 10.0 5 17 10 21 27.5 3 8 KGS10-03 21 19 39.0 26.6 8 1 2 KGS10-04 28 22 20 35 23 18 1 4 3 8 KGS12-02 KGS12-03 8 27.5 22.5 33.5 29 28 46.0 19 12 22 44.5 1 2 KGS12-04 20 10 30 60.0 22 Reference dimensions after R(PT) thread installation. 122 Stainless Steel One-touch Fittings Series KG Female union: KGF Effective orifice(mm 2) Applicable tube O.D.
UP button Selects the mode and the display shown on the Sub display, or increases the switch point. (5) Press and hold the SET button for 2 seconds or longer to complete the simple setting. (If the button is pressed for less than 2 seconds, the setting will be returned to [P_1].)