Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch
Type: L-Shaped Table Type, Cylinder Inner Diameter(Ø): 6, Stroke(mm): 50, Max. Load Mass (Horizontal Mounting)(kg): 0.05~0.8, Table Size Length L(mm): 89.5, Table Material: [Aluminum] Aluminum, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Rolling Guide] Linear guide 1 axis, Table Size Width W(mm): 27, Table Size Height H(mm): 20, Table Parallelism(µm): 45, Table Surface Treatment
Type: L-Shaped Table Type, Cylinder Inner Diameter(Ø): 8, Stroke(mm): 50, Max. Load Mass (Horizontal Mounting)(kg): 1~4.9, Table Size Length L(mm): 108.5, Table Material: [Aluminum] Aluminum, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Rolling Guide] Linear guide 1 axis, Table Size Width W(mm): 32, Table Size Height H(mm): 23, Table Parallelism(µm): 55, Table Surface Treatment
Type: L-Shaped Table Type, Cylinder Inner Diameter(Ø): 8, Stroke(mm): 50, Max. Load Mass (Horizontal Mounting)(kg): 1~4.9, Table Size Length L(mm): 108.5, Table Material: [Aluminum] Aluminum, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Rolling Guide] Linear guide 1 axis, Table Size Width W(mm): 32, Table Size Height H(mm): 23, Table Parallelism(µm): 55, Table Surface Treatment
Type: L-Shaped Table Type, Cylinder Inner Diameter(Ø): 12, Stroke(mm): 50, Max. Load Mass (Horizontal Mounting)(kg): 1~4.9, Table Size Length L(mm): 103, Table Material: [Aluminum] Aluminum, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Rolling Guide] Linear guide 1 axis, Table Size Width W(mm): 39, Table Size Height H(mm): 30, Table Parallelism(µm): 45, Table Surface Treatment
Type: L-Shaped Table Type, Cylinder Inner Diameter(Ø): 20, Stroke(mm): 50, Max. Load Mass (Horizontal Mounting)(kg): 5~9.2, Table Size Length L(mm): 120.5, Table Material: [Aluminum] Aluminum, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Rolling Guide] Linear guide 1 axis, Table Size Width W(mm): 60, Table Size Height H(mm): 46, Table Parallelism(µm): 55, Table Surface Treatment
Type: L-Shaped Table Type, Cylinder Inner Diameter(Ø): 25, Stroke(mm): 50, Max. Load Mass (Horizontal Mounting)(kg): 5~9.2, Table Size Length L(mm): 139.5, Table Material: [Aluminum] Aluminum, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Rolling Guide] Linear guide 1 axis, Table Size Width W(mm): 74, Table Size Height H(mm): 55, Table Parallelism(µm): 60, Table Surface Treatment
(23 to 122F) Inlet air temperature Ambient temperature 5 to 50C (23 to 122F) 5 to 50C (23 to 131F) Outlet air atmospheric pressure dew point Inlet air flow rate l/min (ANR) (SCFM) Note 2) Standard performance 25C (68F) 62 (2.2) 125 (4.4) 250 (8.8) 375 (13.2) 625 (22.1) 900 (31.8) 1190 (42.0) 725 (25.6) 31 (1.1) Outlet air flow rate l/min (ANR) (SCFM) Purge air flow rate l/min (ANR) (SCFM
(1) Ambient and fluid temperature 10 to 50C (1) 10 to 50C (1) Maximum operating frequency 20 Hz 5 Hz 20 Hz Individual EXH Pilot valve EXH Common exhaust Not required Lubrication Non-locking push type/Slotted locking type (tool required) as an option Pilot valve manual override 150/30 m/s2 Shock/Vibration resistance (2) Dustproof Enclosure 12, 24 VDC and 100, 110, 200, 220 VAC Coil rated
0 to 50C Accuracy Note 1) 5% F.S. 3% F.S. 1% F.S.
0 to 50C Linearity Note 1) 5% F.S. or less 3% F.S. or less 1% F.S. or less (connected with PF2W33) Repeatability Note 1) 3% F.S. or less 3% F.S. or less (connected with PF2W2) Temperature characteristics 2% F.S. or less (15 to 35C based on 25C), 3% F.S. or less (0 to 50C, based on 25C) Pulse output, N channel, open drain, output for display unit PF2W3.
) 5% F.S. (0 to 50C) 2% F.S. (15 to 35C) 5% F.S. (0 to 50C) (15 to 35C) 0.5% F.S. (0 to 50C) 0.5% F.S. (0 to 50C) 0.5% F.S. (0 to 50C) 0.5% F.S. (0 to 50C) 5% F.S. (0 to 50C) 5% F.S. (0 to 50C) 5% F.S. (0 to 50C) Repeatability 1% F.S.
Use a pressure gauge below 50C. The Max. operating temperature of the standard accessory Pressure gauge is 50C. If temperature of the air tank exceeds 50C, provide a heat radiator (i.e. pipe siphon, etc.) between the tank and the pressure gauge. 3. Please keep the Class 2 Pressure Vessel Certificate in a safe place.
) 2% F.S. 2% F.S. (15 to 35C) 2% F.S. (15 to 35C) Monitor unit Monitor unit Monitor unit Monitor unit (15 to 35C) 3% F.S. (15 to 35C) 5% F.S. (0 to 50C) 5% F.S. (0 to 50C) 0.5% F.S. 0.5% F.S. 0.5% F.S. (0 to 50C) 0.5% F.S. (0 to 50C) 5% F.S. (0 to 50C) 5% F.S. 5% F.S. (0 to 50C) (0 to 50C) (0 to 50C) (0 to 50C) Repeatability 1% F .S.
The fluid and ambient temperatures are 0 to 50C. Since moisture in the fluid can freeze when used at 5C or below, causing damage and malfunction of switches, consider measures to prevent freezing. The installation of an air dryer is recommended to remove drainage and moisture from circuits.
SY30M--SY3 (R) 0 3 SY50M-SY5 (R) 0 3 SY70M-SY7 (R) 0 3 Interface regulator model Applicable valve model Note 2) Regulating port Set pressure range Maximum operating pressure Fluid Ambient and fluid temperature 1(P), 4(A), 2(B) 0.1 to 0.7 MPa 1.0 MPa Air 10 to 50C (No freezing) 75 69 93 87 Weight [g] Note 3) With pressure gauge Without pressure gauge 33(35) Note 4) 27(29) Note 4) (A)4 2(B)