Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: -, Connector: -, Option: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N63, "VACUUM SWITCH
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting)
Series: 25A-ISE20, Rated Pressure Range: C (-0.1 to 1 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specifications: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N, "PRESSURE SWITCH