Detection nozzle: 1.5 Piping: F type: 4 x 2.5 tube 1 m, 3 m, 5 m Test conditions G, H type: 6 x 4 tube 1 m, 3 m, 5 m Supply pressure: 200 kPa ISA3-F ISA3-G Piping length: 1m, 3m, 5m Piping length: 1m, 3m, 5m : When the display value becomes 9 or lower, "0" is displayed. "0" and "10" are displayed near "10". This does not affect the performance.
1 m 1.5 m 2 m 3 m 5 m 0.5 m 1 m 1.5 m 2 m 3 m 5 m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.
SUP = 0.2 MPa 0.2 0.2 0.1 0.1 0 0 5 0 10 15 20 25 10 0 20 30 40 50 Discharge rate (L/min) Discharge rate (L/min) PAF3413 Air Consumption (4 Hz) PAF5413 Air Consumption (3 Hz) 200 Air consumption (L/min [ANR]) Air consumption (L/min [ANR]) SUP = 0.5 MPa 300 SUP = 0.5 MPa 150 SUP = 0.4 MPa SUP = 0.4 MPa 200 SUP = 0.3 MPa SUP = 0.3 MPa 100 SUP = 0.2 MPa SUP = 0.2 MPa 100 50 0 5 0 0 10 0 10
UT ZPT10UT-A6 4 4 4 4 ZP10UT ZP 13 UT ZPT13UT-A6 4 4 4 4 ZP13UT ZP 16 UT ZPT16UT-A6 4 4 4 4 ZP16UT ZP 10 U ZPG10U-7A-X2 7 7 7 7 ZP10U ZPT2-7A-X2 ZP 13 U ZPG13U-7A-X2 7 7 7 8 ZP13U ZP 16 U ZPG16U-7A-X2 7 7 7 8 ZP16U ZP 20 U ZPG20U-7A-X2 9 10 10 10 ZP20U ZPT3-7A-X2 ZP 25 U ZPG25U-7A-X2 10 10 10 11 ZP25U ZP 32 U ZPG32U-7A-X2 10 11 11 12 ZP32U ZP 10 C ZPG10C-7A-X2 7 7 7 7 ZP10C ZPT2
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ There are other applicable auto switches than listed above. For details, refer to page 775. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785. D-A9/M9/M9W/M9AL auto switches are shipped together (not assembled).
Hysteresis (m) Hysteresis (m) 0.1MPa 40 40 40 Supply pressure 30 30 30 0.1MPa 20 20 20 0.15MPa 0.15MPa 0.15MPa 10 10 10 0.2MPa 0.2MPa 0.2MPa 100 200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
3/h) (273 m 3/h) (384 m 3/h) (510 m 3/h) Air FlowRate (ANR)(Note 1) 120SCFM 173SCFM 258SCFM 353SCFM At Expected Outlet Press.Dew Point of 45 oF (7.2 oC) (205 m 3/h) (294 m 3/h) (438 m 3/h) (600 m 3/h) 130SCFM 181SCFM 297SCFM 406SCFM At Expected Outlet Press.Dew Point of 50 oF (10 oC) (221 m 3/h) (308 m 3/h) (504 m 3/h) (690 m 3/h) Operating Pressure 100psig (0.7MPa) Condition Rated Inlet
and case Insulation resistance 5 M between external terminals and case (at 50 VDC) Vibration resistance 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized) 980 m/s2 in X, Y, Z directions, 3 times each (De-energized) Impact resistance Temperature characteristics (Based on 25C) 2% F .S. or less based on the
Speed Controller for Low Speed Operation Resin Body/Metal Body Series AS-FM/AS-M/ASD-FM Series AS-FM/AS-M/ASD-FM Ideal for low speed control at 10 to 50mm/sec Easy adjustment in low speed ranges Since the effective area of the controlled flow is approximately 1/10 that of the standard model, it is ideal for speed control of low speed cylinders at 10 to 50mm/sec.
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time. Insufficient warm-up time Product failure Replace the product. "M" in the part number means that the unit cannot be changed.
speed mm/s Allowable load weight (Graph (2)) Horizontal (With and without switch) 10 Load weight m (kg) 1 63 50 40 32 m 0.1 10 100 Eccentric distance + Stroke L (mm) l S l: Eccentric distance (mm) S: Stroke (mm) L Cushion Needle Adjustment Warning 1.
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time. Insufficient warm-up time Product failure Replace the product. "M" in the part number means that the units cannot be changed.
UT ZPT10UT-A6 4 4 4 4 ZP10UT ZP 13 UT ZPT13UT-A6 4 4 4 4 ZP13UT ZP 16 UT ZPT16UT-A6 4 4 4 4 ZP16UT ZP 10 U ZPG10U-7A-X2 7 7 7 7 ZP10U ZPT2-7A-X2 ZP 13 U ZPG13U-7A-X2 7 7 7 8 ZP13U ZP 16 U ZPG16U-7A-X2 7 7 7 8 ZP16U ZP 20 U ZPG20U-7A-X2 9 10 10 10 ZP20U ZPT3-7A-X2 ZP 25 U ZPG25U-7A-X2 10 10 10 11 ZP25U ZP 32 U ZPG32U-7A-X2 10 11 11 12 ZP32U ZP 10 C ZPG10C-7A-X2 7 7 7 7 ZP10C ZPT2
UT ZPT10UT-A6 4 4 4 4 ZP10UT ZP 13 UT ZPT13UT-A6 4 4 4 4 ZP13UT ZP 16 UT ZPT16UT-A6 4 4 4 4 ZP16UT ZP 10 U ZPG10U-7A-X2 7 7 7 7 ZP10U ZPT2-7A-X2 ZP 13 U ZPG13U-7A-X2 7 7 7 8 ZP13U ZP 16 U ZPG16U-7A-X2 7 7 7 8 ZP16U ZP 20 U ZPG20U-7A-X2 9 10 10 10 ZP20U ZPT3-7A-X2 ZP 25 U ZPG25U-7A-X2 10 10 10 11 ZP25U ZP 32 U ZPG32U-7A-X2 10 11 11 12 ZP32U ZP 10 C ZPG10C-7A-X2 7 7 7 7 ZP10C ZPT2
) (mm) Solid state auto switch D-M9 Size A 10 6 15 6 20 6 30 6 40 6 Operating Angle and Hysteresis Angle Solid state auto switch D-M9 Size Operating angle (m) Hysteresis angle Note) Since the figures in the table on the left are 10 36o 5o provided as a guideline only, they cannot be guaranteed.
Pushing completed position End position 50 - 10.
Speed Controller Cylinder Solenoid valve Tubing Silencer Max. return speed (mm/s) 10 20 30 6 ASD230FM CJ2 SYJ500 TU0604 1 m AN11001 10 16 Cylinder size 20 ASD330FM CM2 SYJ700 TU0604 1 m AN11001 Cylinder size 25 32 Values are measured at 0.5 MPa and 20C.
Auto Switch Rotation range / Actuation / most sensitive position D-M9 auto switch D-F8 auto switch Size Rotating Operation Operation A B angle Hysteresis Hysteresis angle angle (mm) (mm) angle angle m m 90 20.5 16.5 05 46 10 20 10 180 23.2 19.2 90 22.4 18.4 1 41 10 15 10 180 25.6 21.6 Operating angle m: Value of the operating range Lm of a single auto switch converted to an axial rotating
4 5 6 7 8 < -> LEFS40 LEFS40 10 60 60 10 50 50 W(kg) W(kg) W(kg) W(kg) 40 40 30 30 20 20 10 20 20 10 10 10 0 0 0 100 200 300 400 500 V(mm/s) 0 100 200 300 400 500 V(mm/s) -10- (2)DC24V LEFS16A LEFS25A (mm) 1) 100,200,300,(400) 100,200,300,400 500(600) 7 10 11 18 (kg) ) 2 4 2.5 5 (mm/s) 2) 10500 5250 12500 6250 (mm/s 2) 3,000 (mm) 0.02 (mm) 10 5 12 6 (m/s 2) 3) 50/20 () 540 (%