SMC Corporation of America
Elite Part Number Search
Search Results "HF3-JSX11-SN101F-5WN-D-B"

717 ML2B Series Dimensions Side support A MY-SA 2 x G F E 2 x H A B C D Side support B MY-SB 2 x J A B C D A 61 70 87 B 75 84 105 C D E F G H J Part no.

C11.2 1218 MY1H Series Mechanically Jointed Rodless Cylinder Linear Guide Type Side Support Side support A MY-SA 2 x G F 2 x H E C D A B Side support B MY-SB MY1B 2 x J MY1H MY1H MY1B E A B C D MY1M MY1C (mm) MY1H Part no.

OFF OFF ON OFF OFF C OFF OFF OFF ON OFF D OFF OFF OFF OFF ON E OFF OFF OFF OFF OFF *ALARM SVRESETON SVRE SETON A RESET B RESET C RESET D OFF (1) RESET(1) E OFF OFF 1 SV1.00 SETON OFFSETUP(2) -1 RESET SVRE ONRESET SVON ON 2 SETUP 48 - 12.2 code 12 12 0 1-048 B RESET -+ W 1W 2 W 12 0 1-049 PARA B RESET 1-050 B RESET No.

M9BV D-M9BV M9BWV D-M9BWV A72 D-A72 F9G D-F9G F79W D-F79W Solid State Auto-Switch A73 D-A73 F9H D-F9H F7PW D-F7PW Reed Auto-Switch A80 D-A80 F79 D-F79 J79W D-J79W A72H D-A72H F7P D-F7P F7NWV D-F7NWV A73H D-A73H J79 D-J79 F7BWV D-F7BWV A76H D-A76H J79C D-J79C M9NA D-M9NA A80H D-A80H F7NV D-F7NV M9PA D-M9PA Water Resistant A73C D-A73C F7BV D-F7BV M9BA D-M9BA 2-Color A80C D-A80C F7PV D-F7PV

Note 5) Dimensions other than those marked (LA) are the same as the basic type (no locking type). 598 RS2H Series Auto Switch Mounting 1 Auto Switch Proper Mounting Position (Detection at Stroke End) D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A B Auto switch Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A 9.0 B 23.5 A 11.0

ON OFF D ON OFF OFF OFF ON E ON OFF OFF OFF OFF SVRESETON IO SVRE SETON B RESET C RESET D OFF RESET,SVON E OFF OFF D 1 DSVREOFF(OFF) 2 RESET()SVON SVREON(ON) -62- 15.2 (code)*1 <> () (1)12 (12 0 ) (2) (3) (4) (5) (6) (7) (01-048) B RESET <> <> () (-)(+) W 1W 2 (W 12 0 ) (01-049) PARA B RESET <> <>No.

A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 5 5m Shield Cable color Terminal no.

, B8 D-B73C D-B80C D-G7, K7 D-K79C D-B5, B6 D-G5lW D-K59W D-G5BAL D-G59F D-H7lW D-H7lF D-H7BAL D-C7, C8 D-C73C D-C80C D-G5 D-K5 D-G5NTL D-C73C D-C80C D-B59W D-H7 D-H7C Bore size Hs Hs Hs A 21.5 (29.5) A B 20.5 (28.5) A B 15 (22.5) A B 17.5 (25.5) A B 19.5 (27.5) A B 18 (26) A B 16 (24) B 20 27.5 27 24.5 31 25.5 27.5 29 27 24 30 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 18

Unit Series AV2000-A AV3000-A AV4000-A AV5000-A Spacer Y200-A Y300-A Y400-A Y600-A Spacer with bracket Y200T-A Y300T-A Y400T-A Y600T-A Applicable model AC20-A AC20-B AC25-A, AC30-A AC25-B, AC30-B AC40-A*1 AC40-B*1 AC50-B, AC55-B AC60-B *1 Except port size 06 Assembly Example eSpacer with bracket qSoft start-up valve Air combination wAC30-03G-A Assembly example Products do not come assembled

cable O.D. 6 to 8 (D, DL) Pilot port B (Air operated) L (Terminal with indicator light: DL) M (Conduit terminal: T) K (DIN terminal: D) I (Grommet: G) J (Conduit: C) 4 x 2-18 mounting hole Applicable flange Pilot port Rc A B C D E F G H I J K L M Model VNB5-32F VNB6-40F VNB7-50F 1 8 1 4 1 4 130 150 180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 244 259.5

As a guideline, turn 90o from the position where the mounting screw starts to become tight. 19 - < Applicable Auto switches > Solid state switch D-F59F5P D-J59J51F5BAL D-F59WF5PWJ59W D-F59FF5NTL Reed switch D-A53A54A56A64A67 D-A59W How to mount and move the auto switch Fig. 9 Fix the auto switch to the auto switch mounting bracket using auto switch mounting screw (M4).

When auto switches D-M9/M9W/Y59 D-Y7, Y7W are used A B L Auto Switch Hysteresis When auto switches D-M9V/M9WV/Y69 D-Y7V, Y7WV are used Auto switches have hysteresis similar to micro switches. Use the table below as a guide when adjusting auto switch positions, etc. A B MHZ L MHF MHL Max.

Proper Auto Switch Mounting Position (Detection at stroke end) MX A B MTS MY MY3A D-A9, D-A9V (mm) D-F9W, D-F9(W)V (mm) D-M9, D-M9V (mm) CY A B Operating range Bore size 16 25 40 63 A B Operating range Bore size 16 25 40 63 B Operating range Bore size 16 25 40 63 A 088.5 084.5 26.5 084.5 22.0 26.5 2 06.5 3.0 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080

lines in clean room environments TPH 06 04 B 20 Tube O.D.

L L 1===:: . e ~l Nut ftO'a E . d Nilt ;1 ' , 0 , d d u {} B I I H B ILH ~ I Model j Bore,size(rnm} . d , I .Ji'.. ..I ~. e ~:C _ ~1IlIOB~sjze (mh''' d, H B C I NTP.()06 I 6 M3XQ.5 1.8 5,5 6,' SNP.oo6 6 Ml0X1.0 3 I. 16.2 _ ~.c1D. '1.0 Mt2X1.0 3 17 19,6 I NTP.()10 10' . M4 X0;7 2.4 , "la.tV NTP.()15 15 M5XO.a I 3,2 I 8 9.2 L.

Class Size combination Applicable tubing size (mm) 4 x 3 3 x 2 6 x 4 4 x 3 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 12 x 10 10 x 8 19 x 16 12 x 10 19 x 16 12 x 10 25 x 22 19 x 16 25 x 22 19 x 16 Connection threads Symbol 1 2 2 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 Connection threads A A B C D E F A B C D A B C D A B C D A B C D Applicable tubing size (inch) No.

IO-Link Port 4 event flag RY(n+2).B Reserve RX(n+3).C RY(n+2).C RX(n+3).D RY(n+2).D Reserve RX(n+3).E RY(n+2).E RX(n+3).F RY(n+2).F n: Start address -42No.EX-OMW1003-A Bit area (3) Input register Slave -> Master Output register Master -> Slave Corresponding Unit No.

D A B Grommet with membrane Power cable outlet (17) Dimensions (mm) A 230 B C D Circuit breaker Model 32 B D IDFA4E, 6E, 8E, 11E IDFA15E1 67 179 43 258 77 158 C E A IDFA22E to 75E Power cable outlet (17) (Wire diameter 9 to 11) F (mm) Dimensions E D C B A F Model Signal cable outlet (Wire diameter 17) Grommet with membrane IDFA22E IDFA37E IDFA55E IDFA75E 59 125 40 25 46 39 60 Terminal block

D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V 20 to 63 B A Hs 32 to 63 D-P3DWA B A Hs Auto Switch Proper Mounting Position Auto Switch Mounting Height (mm) (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5 13 15 16 20 A 11 10.5 12 14 13.5 16.5 B 7 8.5 9 11 12 16 A 6 7.5