1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)
2% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)
1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)
Please contact us for the latest version.sales@ocaire.com, GAUGE 1/4 PT 0-4KG *LQA, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .11023 lb, ModelPressure range (1)Indication unitConnection threadNote MPaG46-4-01/020 to 0.4MPaR 1 8, 1 4?
1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)
1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)
1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?4 to 6.5When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa)UniversalNot required (3)
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
VFS2000, body ported and base mounted valves, Thread type: Rc(PT), Port sizes: 1/8, 1/4, Maximum operating pressure: 9.9kgf/cm2, Ambient and fluid temperature: -10 to 60 C, Manual override: non locking push style, SUBPLATE (NVFSA2501-01-02T), VALVE, VFS2000 SOL VALVE 4/5 PORT, D2, VFS2000 BODY PT 1/8, 0.2926 lb
(full span), GAUGE 1/4 PT 0-4KG, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .16413 lb, ModelPressure range (1)Indication unitConnection threadNote MPaG46-4-01/020 to 0.4MPaR 1 8, 1 4?
4 orifice dia.), 3 (?8 orifice dia.), 4 (?10 orifice dia.) , Normally closed (N.C.) , Port size: 01 (1/8), 02 (1/4), 03 (3/8), 04 (1/2), Pilot port thread: Rc, NPT VALVE. VALVE. FLUOROPOLYMER. .88184 lb.
4 orifice dia.), 3 (?8 orifice dia.), 4 (?10 orifice dia.) , Normally closed (N.C.) , Port size: 01 (1/8), 02 (1/4), 03 (3/8), 04 (1/2), Pilot port thread: Rc, NPT VALVE. VALVE. FLUOROPOLYMER. .15521 lb.
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread Type: N (NPT), Port Size: 02 (1/4), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 01 (Ø1/8), Seal Method: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread Type: R, Port Size: 01 (1/8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 07 (Ø1/4), Seal Method: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Thread Type: N (NPT), Port Size: 01 (1/8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 07 (Ø1/4), Seal Method: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Thread Type: N (NPT), Port Size: 01 (1/8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 07 (Ø1/4), Seal Method: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 1 (Meter-in), Thread Type: N (NPT), Port Size: 01 (1/8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 07 (Ø1/4), Seal Method: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Thread Type: R, Port Size: 01 (1/8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 07 (Ø1/4), Seal Method: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Thread Type: R, Port Size: 01 (1/8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 07 (Ø1/4), Seal Method: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread Type: R, Port Size: 02 (1/4), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 01 (Ø1/8), Seal Method: S (with Sealant)