Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 04 (1/2), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)
Body Size: 60, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 04 (1/2), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 02 (1/4), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 03 (3/8), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, ML, 40MM NCQ2-Z NON-ROT AUTO-S, 0.95239 lb
Refer to the operation manual on the SMC website for details. The SI unit part number (EX□-□) is determined by the valve manifold model. Refer to the SI unit part numbers in the valve catalog.
The D-MP□ series operation manual can be found here.