x 22 25 x 22 25 x 22 25 x 22 25 x 22 25 x 22 25 x 22 12 x 10 25 x 22 25 x 22 25 x 22 25 x 22 25 x 22 25 x 22 25 x 22 25 x 22 19 x 16 19 x 16 6 x 4 3/8" x 1/4" 1/4" x 5/32" 1/4" x 5/32" 1/8" x 0.086" 3/8" x 1/4" 3/8" x 1/4" 1/2" x 3/8" 1/2" x 3/8" 1/2" x 3/8" 1/2" x 3/8" 1/2" x 3/8" 1/2" x 3/8" 1/4" x 5/32" 1/2" x 3/8" 1/2" x 3/8" 1/8" x 0.086" 3/4" x 5/8" 3/4" x 5/8" 3/4" x 5/8" 3/4" x 5
D-G5NTL 75 + 50 (n-2) 15 75 30.5 38 43 50 A B 0 (1) 0.5 2 2 D-A3 D-G3, D-K3 100 + 100 (n-2) 35 + 30 (n-2) 35 100 D-B5, D-B6 33.5 23.5 25 25 Approx. Hs 25.5 (28.5) 38 43.5 50.5 D-A4 35 + 30 (n-2) 50 + 50 (n-2) 35 55 A B 0 2 3.5 3.5 D-G5NTL 27 25 26.5 26.5 Approx. Hs 33.5 38 43.5 50.5 A B 0 1.5 1.5 D-A3 D-G3, D-K3 23 24.5 24.5 Approx.
DZ/Y/YZ VFS3320-D/DZ/Y/YZ VFS3420-D/DZ/Y/YZ VFS3520-D/DZ/Y/YZ Lead wire O.D.
CY3RG25 CY3RG32 CY3RG40 16 Series CY3R Auto Switch Proper Mounting Position for Stroke End Detection Auto Switch Operation Range (Reference dimension) Bore size (mm) Auto switch model 15 20 25 32 40 D-A9 8 6 D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.
12.8 13.9 11.0 8 KGLU08-00 15.2 26.3 18.2 15 KGLU10-00 18.5 40.8 29.0 25 10.4 12.8 15.2 18.5 20.9 T VMG KGLU12-00 20.9 57.2 45.2 32 12 Note) D: Max. diameter 3-applicable tubing Plug-in Elbow: KGL Effective area (mm2) Urethane Nylon Applicable tube O.D. mm Applicable fitting size d Note) D2 M Weight (g) L1 L2 A D1 Model Applicable tubing KGL04-99 8 10 12 6 4 6 4 18 20 22.5 25 27.5 31.5 14.5
type /In-line motor type Series LEY;D Series LEY Series LEYG Series LEYG;D CAT.NAS100-83 Series LEY (Motor parallel) Series LEY (In-line motor) Series LEYG (Motor parallel) Series LEYG (In-line motor) Size Stroke Pushing force lbf (N) Size Stroke Pushing force lbf (N) Size Stroke Pushing force lbf (N) Size Stroke Pushing force (mm) (mm) (mm) lbf (N) (mm) 25 32 25 32 25 32 30 to 300 25 32
Flange size XMA Symbol Nil D C Type KF (NW) K (DN) CF Applicable flange size 16, 25, 40, 50, 63, 80 63, 80 16 (034), 40 (070), 63 (114) XMA V V V V V V XYA V V V V V Size 16 25 40 50 63 80 XYA Nil D K (DN) KF (NW) 25, 40, 50, 63, 80 63, 80 3.
Auto Switches/Proper Mounting Position at Stroke End Detection B A (mm) D-A9, D-A9V (mm) D-M9, D-M9V (mm) D-F9W, D-F9WV A A A B B B Operating range Operating range Operating range Nominal size 16 25 Nominal size 16 25 Nominal size 16 25 3 44 116 48 112 48 112 8 8.5 3.5 54 156 58 152 58 152 Auto Switch Mounting When mounting the auto switches, they should be inserted into the actuators switch
Model H G A B C J* K E D F 16.5 MXS-AT6 5 MXS 6 7 21 19 8 5 10.5 2.5 M2.5 X 8 M5 X 0.8 * MXS6, MXS8 26.5 MXS-AT6-X11 15 D 16.5 MXS-AT8 5 E E H MXS 8 M3 X 10 M6 X 1 8 25 9 6 12.5 3 22.5 26.5 MXS-AT8-X11 15 36.5 MXS-AT8-X12 25 5 G 20 MXS-AT12 MXS12 12 32 13 8 18.5 4 31 M4 X 8 M8 X 1 30 MXS-AT12-X11 15 B C 40 MXS-AT12-X12 25 24.5 MXS-AT16 5 F K K F A J MXS16 M5 X 10 M10 X 1 14 40 15 10 23 5
, D-F9WV D-M9 , D-F9W D-A9V D-F9V D-M9N B P D-F9BA No. of auto switches 15 20 25 10 10 5 2 10 15 20 25 5 5 1 Consult P/A for shorter stroke lengths than indicated in the table.
(mm) D-M9V D-M9WV D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A90V D-A96V D-A93V Bore size (mm) D-A90 D-A96 D-A93 D-M9 D-M9W Bore size (mm) Mounting pattern q, w Mounting pattern e 32 32 20 22 35 20 10 15 25 12 5 10 Mounting of Auto Switch As shown below, there are 3 ways to mount the auto switch according to 3 types of electrical entries.
D-Y69A, D-Y69B, D-Y7PV D-Y7NWV, D-Y7PWV, D-Y7BWV ( ) MY1CW 25, 32, 40, 50, 63 B A Solid state switch D-Y59 , D-Y69 , D-Y7P(V) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) A B A B Reed switch D-Z73, D-Z76, D-Z80 D-Y7BAL 63 50 40 32 25 Mounting position 40 32 25 Mounting position 25 Mounting position 32 40 50 63 A 323.5 278.5 157.5 127.5 97.5 157.5 127.5 97.5 97.5 127.5 157.5 278.5 323.5 A A B 136.5 121.5
D-F7WV D-F79F D-A7H D-A80H D-F7 D-J79 D-F7W D-F7BAL D-J79W D-F79F D-F7NTL DD-M9 D-M9V D-F7V D-A7 D-A80 D-F7BAVL D-J79C D-A79W D-A9V D-M9V D-A73C D-A80C D-A79W D-A9 D-A9V Bore size (mm) D-A7 D-A80 D-F7WV D-F9WV D-F9BAL -X D-F9BAL D-F9WV D-F9W 20Data B A B A B A B A B A B A U U U U U U U U U 12 16 20 32 40 50 9 4 13 8 12 7 17 19.5 16.5 11.5 11.5 12 12 9 9 22.5 23.5 29.5 26 29 25 17.5 9.5 18
(Not mountable after the time of shipment) Auto Switch Mounting Height D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G59F D-F5 D-J5 D-F5W D-J59W D-F59F D-F5NTL Auto switch model D-Z7/Z80 D-Y59 D-Y7P D-Y7W D-A3C D-G39C D-K39C D-A44 D-A44C D-A3 D-G39 D-K39 D-Y69 D-Y7PV D-Y7WV D-A5 D-A6 D-A59W Bore size (mm) Hs Hs Ht Hs Ht Hs Ht Hs Hs Ht Hs Hw Hs Hw Hs 40 38 40 31 38.5 31 30.5 30 72.5 73
C D E F Dimensions Part no.
GR-S-010 (10 g) GR-S-020 (20 g) Guide unit GR-L-005 (5 g) GR-L-010 (10 g) Cylinder unit High carbon chrome bearing steel Stainless steel NBR NBR NBR 25 Series MXQR Auto Switch Proper Mounting Position (Detection at Stroke End) Solid State Auto Switch: D-M9B, D-M9N, D-M9P, D-M9BW, D-M9NW, D-M9PW Stroke B Stroke E A Model 10 20 30 125 75 100 40 50 150 10 20 30 125 75 100 40 50 150 MXQR6 17.5
9P Applicable lube O D oP t'j oA l:M5x0 8 l:[t6x1 . gL D E D I E R(FB 6 7 2 5 20 25 71 5 3 3 9.1 4 I I 4 7 1 0 . 1 Tube Applicable tube o.D. 6P R sS q4 4 20.615.61 0 . 4 s6 6 2 1 . 6 16.6 12.8 Tube Applicable tube O.D o P o4 4 1 5 . 8 1 1 0 . 4 s6 6 24.316.81 12.8 Pad Diameters o1O. @13. @16 68 I 18.7 | 15.2 Bellows type Pad Diameters @4O. @5O Fr4q!
HW H H' T' Z Auto switch model D-A3C-4, D-A44C-4 D-A3C-5, D-A44C-5 D-A3C-6, D-A44C-6 D-A3C-8, D-A44C-8 D-A3C-10, D-A44C-10 69 77 91 107 121 58 (67.5) 59 (68.5) 61.5 (71) 65 (74.5) 68 (77.5) 50.5 (60) 51.5 (61) 53 (62.5) 54.5 (64) 57.5 (67) 6.5 6.5 7.5 9.5 9.5 7.5 8.5 10.5 12.5 15.5 M5 x 0.8 x 16 M5 x 0.8 x 20 M5 x 0.8 x 25 ( ): Denotes the values of D-A44C Dimensions (mm) D-A3C D-A44C 2