(Fig. 5-1, Fig. 5-2) Reference: For the bilateral piping type: The full length of the cylinder is shorter than the centralized piping type: Integrated piping is possible. Plate C Plate A Piping Piping Fig.5-1 Bilateral piping type [CY1S] Plate B Plate A Piping Fig,5-2 Centralized piping type [CY1SG] 9/28 3-2) Stopper type Select the stopper from the three types on the right.
7 8.5 9 10 D-H7C D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL 4 4 4.5 5 6 45 D-G59F D-G5NBL 5 35 5 40 5.5 40 Since this is a guideline including hysteresis, not meant to be guaranteed.
7 8.5 9 10 D-H7C D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL 4 4 4.5 5 6 45 D-G59F D-G5NBL 5 35 5 40 5.5 40 Since this is a guideline including hysteresis, not meant to be guaranteed.
3 PA 0.54 13 0.8 4 1/4 (8A) 3/8 (10A) 1/2 (15A) 1/4: 0.42 3/8: 0.40 1/2: 0.49 VCS3 3 0.80 19 0.5 5 1.0 PAX 1.4 33 0.2 7 2.1 50 0.1 10 PB 0.35 8.4 1.0 3 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) 1/4: 0.58 3/8: 0.55 1/2: 0.62 3/4: 0.78 0.60 14 1.0 4 0.85 20 0.7 5 VCS4 1.0 4 1.4 33 0.3 7 2.1 50 0.12 10 Note 1) Refer to page 17-2-42 in model selection regarding port size and orifice size combinations
Note 4) Assembly of a bracket and set nuts Standard Specifications AWM20 AWD20 AWM30 AWD30 AWM40 AWD40 Model Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Set pressure range 0.05 to 0.85 MPa Pressure gauge port size Note 1) 1/8 1/4 Ambient and fluid temperature Note 2) 5 to 60C (with no freezing) AWM20 to AWM40 0.3 m (95% filtered
Note 4) Assembly of a bracket and set nuts Standard Specifications AWM20 AWD20 AWM30 AWD30 AWM40 AWD40 Model Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Set pressure range 0.05 to 0.85 MPa Pressure gauge port size Note 1) 1/8 1/4 Ambient and fluid temperature Note 2) 5 to 60C (with no freezing) AWM20 to AWM40 0.3 m (95% filtered
(see Figure 2) Caution (1) Install an air filter. Install an air filter at the upstream side of valve. Select a filtration rating of 5 m or below, or that equivalent to or lower than ISO 8573-1:2010 [6:4:4] * This rating is equivalent to the rating produced when an air filter is installed for the purity class [7:4:4] of the inlet side compressed air.
The above CSA NRTL/C logo is described on a product label in order to indicate that the product is approved by CSA and UL Standards. TSSA (MCCR) Registration Products TSSA is the regulation in Ontario State, Canada. The products that the operating pressure is more than 5 psi (0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation.
Add -XB10 to the end of standard model number. 12, 16 1 to 249 12, 16 11 to 249 Applicable stroke 20, 25, 32 1 to 399 20, 25, 32 21 to 399 mm) 40 to 100 5 to 395 40 to 100 26 to 395 Part no.: MGQM20-39 Part no.: MGQM20-39-XB10 A spacer 1 mm in width is installed in the MGQM20-40. Special body manufactured for 39 stroke. Example C dimension is 77 mm. C dimension is 76 mm. 6.
Current output Voltage output Hysteresis mode Window comparator mode Variable (0 to variable) Note 1) 1 to 5 V 2.5% F.S.
Lubrication Temperature Allowable voltage fluctuation Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) 5 to 50C (Air operated type: 60C) Note 1) SGC 35C or less (when rated voltage is applied.) 50C or less (when rated voltage is applied.)
VKF How to Order Valve Manifold Assembly VQZ Ordering example VZ Stations 5 4 3 2 1 Valve (N.C.) V114-5GZ VS VFN 2 1 3 2 Blank plate assembly V100-77-1A Manifold base (5 stations) VV100-S41-05-M5 VV100-S41-05-M5 1 set (Type S41, 5 station manifold base part no.)
Limited warranty and Disclaimer 1.The warranty period of the product is 1 year in service or 1.5 years after the product is delivered,whichever is first.2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2.
If air is supplied to 2(A) port, air leaks from 1(P) port leading to operation failure. 4. Allows sufficient margin in the piping conditions of the tubing. 5. Prevent the connected tube from being rotated. If the fittings are used in this way, the fitting is likely to break. 4 Mounting ! Warning 1.
If a pump is operated by super dry air and N2 gas, etc., the deterioration of the gaskets inside the switching valve will be accelerated and may result in substantially shortening the life span of the product. 5. Operating environment Warning 1.
Jumping of pressure compensating mechanism Be aware that the amount of jumping that is shown in Fig. (5) applies to the pressure compensation mechanism during the operation of the cylinder. Jumping is a condition in which the cylinder operates without control at a speed that is higher than the control speed. Skip valve 1.
How to order HF2BFB 30 02 (1) (2) (3) (4) (5) (2) Symbol Details Body size 30 40 BFA Antibacterial Filter (5m) BFB Antibacterial Filter (0.1m) (1) Filter type BFC Odor Removal Filter BFD Bacteria Removal Filter Nil Rc N NPT (3) Thread type F G 02 1/4 (4) Port size 03 3/8 04 1/2 Nil Flow direction: left to right (5) Semi-standard R Flow direction: right to left 10 5.
Refer to the page 58 for details. 4.5 5 5 Circuit Diagram Power supply terminal block PCW-EC16Z00 PCW-EC16Z01 20 18 16 14 12 10 8 6 4 2 Input/output connector (CS0) 0 1 2 3 4 5 6 7 19 17 15 13 11 9 7 5 3 1 Green Red F E D C B A 9 8 9 8 7 6 5 4 3 2 1 0 F E D C B A 4 3 2 1 CN1 4 3 2 1 CN2 4 3 2 1 CN3 4 3 2 1 CN4 4 3 2 1 CN5 4 3 2 1 CN6 4 3 2 1 CN7 4 3 2 1 CN8 4 3 2 1 CN9 4 3 2 1 CNA 4 3 2 1
The above CSA NRTL/C logo is described on a product label in order to indicate that the product is approved by CSA and UL Standards. TSSA (MCCR) Registration Products TSSA is the regulation in Ontario State, Canada. The products that the operating pressure is more than 5 psi (0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation.
IP8000-011-AG) Note 3) A is applied to approx 90cm3-capacity actuator. B is applied to approx 180cm3-capacity actuator. Note 4) Standard lever is not attached. Note 5) It is to be used together with A or B when tending to overshoot by the use of A or B. It is mounted to the body as a replacement of the standard compensation spring. Note 6) With terminal box, Non-explosion proof.