SMC Corporation of America
Elite Part Number Search
Search Results "10-VQ2100Y-5"

Grommet (G), (H): V11 24(A)-G H-M5 13.1 (Light/Surge voltage suppressor) 5 + 13 15.5 3 13 3 28.5 [32.4] 10 G: Approx. 300 H: Approx.600 (Lead wire length) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 30.9 [33.1] 25.1 11.4 5.7 5.7 5.7 2 1 7 5 9.5 5 19 (Piping

IR-A How to Order IR VVEXB 5 01 1 IRV VEX VEX Body size Thread type Nil F N T Port size Rc G Note) SRH Pilot type Internal pilot Common external pilot Valve stations 01 8 1 1 2 NPT NPTF SRP 2 2 stations SRF 10 10 stations ITV VVEX2 5 02 1 IC Body size Thread type Rc G Note) ITVH Port size Nil F N T Pilot type 4 1 02 ITVX 1 2 NPT NPTF Internal pilot Common external pilot 2 stations Valve stations

5 q u o Material Note Component Parts !4 r No. q w e r t y u i o !0 !1 !2 !3 !4 !5 !6 !

This will allow for incremental spacing to prevent harmful large initial surge. 10 XL-OMV0007 5. Construction and Dimensions 5-1.

Ratio of resistance [k m] 100 10 50 Particle ratio [number/cc] 1 0 5 10 15 20 25 30 Duration of flow [min] 2 or 3 particles/cc Tube 00 10 20 30 40 50 60 70 Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room (1 l/min flow rate).

5.5 M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1.0 32 38 47 52 5 6 8 10 3.5 3.5 4.5 5 15.5 20 25.5 28 3.5 3.5 5.4 5.4 M4 x 0.7 M4 x 0.7 M6 x 1.0 M6 x 1.0 6.5 6.5 9 9 7.5 7.5 9 11 7 7 10 10 4 4 7 7 0.5 0.5 1 1 Note 1) Threaded through hole is used for the standard of 20 with 5 to 10 mm strokes and 25 with a 5 mm stroke. 3

Model Screw Max. tightening Maximum screw-in depth (L mm) torque (Nm) MHZ2-10 M3 x 0.5 0.9 6 MHZ2-16 M4x0.7 1.6 4.5 MHZ2-20 M5 x 0.8 3.3 8 L L MHZ2-25 M6x1 5.9 10 MHZ2-32 M6x1 5.9 10 MHZ2-40 M8 x 1.25 13.7 13 Model Screw Max. tightening torque (Nm) Maximum screw-in depth (L mm) MHZ2-10 M3 x 0.5 0.69 5 MHZ2-16 M4x0.7 2.1 8 MHZ2-20 M5 x 0.8 4.3 10 MHZ2-25 M6x1 7.3 12 MHZ2-32 M6x1 7.9 13 MHZ2

2 3.5 5 KRP-10 KRP-12 8 35 16 10 39 18.5 12 43 20 14 46 22 VMG 8 10 12 Applicable fitting Spatter Cover 1: KR (Applicable tube: FR soft nylon) Applicable fitting size Model Weight (g) D L KR-08C KR-06C 6 0.9 1.0 1.5 1.6 KR-10C KR-12C 15.5 9 17 9 20.8 10.5 22.8 10.5 8 10 12 When tube insert parts are in line as KQU Union Y, use KRC1.

Value 7 6 5 4 3 2 1 0 Value 7 6 5 4 3 2 1 0 Output No. 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 1 0-7 All clear output Setting value 00 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 Output No. 15 14 13 12 11 10 9 8 15 14 13 12 11 10 9 8 2 8-15 All hold last state Setting value FF 1 1 1 1 1 1 1 1 00 0 0 0 0 0 0 0 0 Output No. 23 22 21 20 19 18 17 16 23 22 21 20 19 18 17 16 3 16-23 All force output Setting value

Value range: 10 10, in 1 ms increments Unit: ms F_WD_Time 150 A CRC signature, which is calculated automatically via all F-Parameters and ensures error-free transmission of the F-Parameters.

9 5 Needle seat (Material SUS304) 4 5 10 4 10 S valve seal O ring XLD-25 S valve seal O ring XLD-40,XLD-50,XLD-160 XLD-63,XLD-80,XLD-100 S valve assembly (Maintenance part) Note 1 (Material SUS304 + Seal material) 4 Note1) The O ring of the S valve seal assembly Initial pumping valve seal (Maintenance part) cannot be replaced.It is necessary to replace the whole assembly. 5 Fixing ring 6

: E) In the case of EZ or TZ, the length is longer by 10 mm.

(P.16) 9 - 4ON DC24V LED POWER ALARM LEDPWR LEDALM CN4 I/O 12.P.48 5() , () 6 10 - 3. 3.1.

10 -20 -20 -20 -20 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0 0 10 20 0 0 0 5 10 15 20 25 Supply pressure MPa Suction flow rate l/min (ANR) Supply pressure MPa Suction flow rate l/min (ANR) ZY -10S Max. vacuum pressure: 84KPa {630mmHg} Y3 X3 ZY -10L Max. vacuum pressure: 53KPa{400mmHg} Y3 X3 Exhaust characteristics Flow rate characteristics Exhaust characteristics Flow

Dispersion within the display accuracy range Pressure display difference when using 2 or more Pressure switches Check if the dispersion is within the display accuracy range. 10 Product failure Replace the product. Install a 5 m filter to prevent foreign matter from getting into the pressure port. Also, clean the filter regularly to prevent drainage deposits.

Dispersion within the display accuracy range Pressure display difference when using 2 or more Pressure switches Check if the dispersion is within the display accuracy range. 10 Product failure Replace the product. -51NO.ZK2-OM00501-B Error No. Problem Possible cause Investigation method Countermeasure Install a 5 m filter to prevent foreign matter from getting into the pressure port.

Dispersion within the display accuracy range Pressure display difference when using 2 or more Pressure switches Check if the dispersion is within the display accuracy range. 10 Product failure Replace the product. -50NO.ZL3-OM00701-A Error No. Problem Possible cause Investigation method Countermeasure Install a 5 m filter to prevent foreign matter from getting into the pressure port.

Dispersion within the display accuracy range Pressure display difference when using 2 or more Pressure switches Check if the dispersion is within the display accuracy range. 10 Product failure Replace the product. Install a 5 m filter to prevent foreign matter from getting into the pressure port. Also, clean the filter regularly to prevent drainage deposits.