Manual override P L 5 24 VDC 02 Rc 1/4 (8A) Rc 3/8 (10A) 9 Other 03 3-9-1 2 Series VS410 Accessory (Option) Apparent Power (Power Consumption) 1.
A Note 1) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12
Rc G NPT NPTF Nil F N T Stations 02 : 10 2 stations : 10 stations D side U side 1 2 3 4 5 02 1/4 (8A) OUT port size How to Order Valves (VCA20) VC A 2 3 1 G 3 For air Orifice size Orifice size (mm) 3 5 Symbol 3 5 2 Class 2 Series Manual override 3 N.C. for manifold Valve type Nil B None Slotted locking type (tool required) Electrical entry Fluid G C T TL D DL DO Grommet Conduit Conduit terminal
15.5 (N)AS2000-01 3/4 51.5 56 20 4.5 40 30 5 23 11.5 17 (N)AS2000-02 1/4, 3/8 61 68 26 5.5 56 45.5 5.25 25 13.2 20.6 (N)AS3000-02, 03 Courtesy of Steven Engineering, Inc. !
Made to Order Body size 100 200 205 300 400 M3, M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard Grease-free (Sealant: Fluoro coated) + Restrictor (Without Check Valve) -X21 Metric size 02 23 04 06 08 10 12 Inch size 01 03 07 09 11 13 Lock nut option 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" 2 3.2 Ex.)
) G1/2 (Cable 8 to 10) 153(166) 153(166) 141(154) 108.5(121.5) 141(154) 108.5(121.5) 50(63) 50(63) 5 3 38(53) 5 3 38(53) 32(42) 23(30) 32(42) 23(30) 1 1 2-3/8, 1/2, 3/4 2-3/8, 1/2, 3/4 3/8, 1/2, 3/4 R1, R2 port X(PE) port 1/8 3/8, 1/2, 3/4 R1, R2 port X(PE) port 1/8 30(42) 30(42) 30(42) 30(42) P port P port ( ): 3/4 Dimensions inside are for rubber seals. ( ): 3/4 3-10-24 25 ISO Standard
and maintenance space . 3-9 3.3 Installation . 3-10 3.3.1 Installation . 3-10 3.3.2 Electrical wiring . 3-12 3.3.3 Preparation and wiring of power supply cable . 3-14 3.3.4 Contact input/output communicatin wiring . 3-19 HRSH Series HRX-OM-Q026 Contents 3.3.5 Wiring of run/stop signal input and remote signal input . 3-19 3.3.6 Wiring of external switch signal input . 3-22 3.3.7 Wiring of
Fig. 3-13 Wiring of the external switch (PNP open collector output) (example) HRS Series 3.3Installation 3-23 HRX-OM-S004 Chapter 3 Transport and Setting Up Setting items Table 3-10 shows the setting items of the external switch. For details, refer to 5.21 Communication function.
: Variable Variable 1 to 10% Fixed 3% F.S. or less Fixed 3% F.S. or less Hysteresis mode: Variable Window comparator mode: Fixed (3 digits) Digit is min. calibration unit.
Cotter pin size C type, 9 for shaft C type, 9 for shaft 3 x 18l 3 x 18l Size Tolerance -0.013 -0.035 -0.013 -0.035 -0.016 -0.043 -0.016 -0.043 AD-EI-20 AD-EI-25 AD-EI-32 AD-EI-40 20 25 32 40 45.5 45.5 52 60 35.5 35.5 42 50 3.2 3.2 4 4 10 10 12 12 +0.058 0 +0.2 +0.1 Y-02 14 5 20 18 M8 x 1.25 36 16 9 3.2 x 16l 20 CDP-1 9 +0.058 0 +0.2 +0.1 Y-03 14 5 20 18 M10 x 1.25 38 18 9 25 CDP-1 9 4 x 20l
D side Stations 1 2 3 4 5 6 7 8 9 10 11 12 Description/Model (A) 4 (B) 2 2 position single 1 (P)3 (R2) 5 (R1) (A) 4 (B) 2 2 position double 1 (P)3 (R2) 5 (R1) (A) 4 (B) 2 3 position closed center Valves Options Port size (ports A, B) Enter in case of mixed sizes (CM). 1 (P)3 (R2) 5 (R1) (A) 4 (B) 2 3 position exhaust center 1 (P)3 (R2) 5 (R1) (A) 4 (B) 2 3 position pressure center 1 (P)3
Valve type Thread type (for single unit only) Rc G NPT NPTF Nil F N T OUT(2) 1 IN(1) Port size Fluid Symbol 02 03 04 06 Class 3 Class 2 Port size 1/4 (8A) 3/8(10A) 1/2(15A) 3/4(20A) Class 4 General air Dry air Nil A Voltage 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Orifice size Orifice size (mm) 3 4 5 7 10 Class 3 Class 2 Class 4 Symbol 3 4 5 7 10 Please consult
2(B) (A)4 Symbol Applicable series Nil Port size Without sub-plate 2 1 8 (EA)5 1 (P) 3(EB) 01 SYA3000 With sub-plate 1 4 3 position closed center With sub-plate 02 SYA5000 2(B) (A)4 1 4 3 With sub-plate 02 SYA7000 (EA)5 1 (P) 3(EB) 3 8 With sub-plate 03 3 position exhaust center 2(B) (A)4 4 (EA)5 1 (P) 3(EB) 3 position pressure center 2(B) (A)4 5 (EA)5 1 (P) 3(EB) 1458 5 Port Air Operated
(Maximum 10 stations) Example) IITV00-05-07 02 03 2 stations 3 stations Indicate part numbers in order starting from the first station on the D side. 10 10 stations Note) Combination with having different pressure ranges is not available due to common supply/exhaust features. Note) A DIN rail with the length specified by the number of stations is attached to the manifold.
N NPT Port size Without sub-plate Symbol Applicable series Nil NPTF T 2 position double 1 8 01 SYA3000 Port size With sub-plate 2 1 4 Port size Without sub-plate Symbol Nil With sub-plate 02 SYA5000 1 4 3 position closed center 02 With sub-plate 3 3 8 With sub-plate 03 3 position exhaust center 4 3 position pressure center 5 1728 5 Port Air Operated Valve Series SYA3000/5000/7000 Specifications
A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8
A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8
Series VXZ22/23 How to Order Model Port size (Rc 1/4) (Rc 3/8) (Rc 1/2) (Rc 3/4) (Rc 1) 02 03 04 06 10 2230 2230 2240 2350 2360 Electrical option Nil None With surge voltage suppressor With indicator light With light/surge voltage suppressor Thread type S Nil Rc L T NPTF F G Z N NPT Refer to the table (1) given below for availability. VXZ 2230 02 1 G N.C.
7 PFM (12) 2 (11) 10 0.210(5)L/min 1 25 0.525(12.5)L/min (11) 50 150(25)L/min 11 2100(50)L/min 1( )CO2 A 2 2 S () N 3 M SI4 3 (SI) 4L/min,L A NPN(2) B PNP(2) C NPN(1)+(15V) D NPN(1)+(420mA) E PNP(1)+(15V) F PNP(1)+(420mA) G NPN(1)+5 H PNP(1)+5 5 L 6INOUT () 10 25 50 11 01 Rc1/8 02 Rc1/4 N01 NPT1/8 N02 NPT1/4 F01 G1/8 F02 G1/4 C4 4(5/32") C6 6 C8 8(5/16") N7 1/4 -10No.PF-OMJ0005CN-I
Kodanska 46, CZ-100 10 Prague 10 Phone: 02-67154 790, Fax: 02-67154 793 Hungary SMC Hungary Kft. Budafoki ut 107-113, 1117 Budapest Phone: 01-204 4366, Fax: 01-204 4371 Sweden SMC Pneumatics Sweden A.B. Ekhagsvgen 29-31, S-14105 Huddinge Phone: 08-603 07 00, Fax: 08-603 07 10 Ireland SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co.