The end angular speed is obtained by: t Table 9 Allowable kinetic energy (J) Size Allowable kinetic energy : Rotation angle [ rad ] : Rotation time [ s ] 1 0.001 Kinetic energy E is obtained by: 2 0.0015 3 0.002 7 0.006 E Therefore, the rotary table rotation time is: E: Allowable kinetic energy [ J ] : Rotation range [ rad ] I: Moment of inertia [ kgm2 ] During uniform acceleration, the
Rc(PT) Thread F G(PF) N NPT Accessories Options Table: Accessory/Option combinations Available Not available Depending on model L D J T AM150 R AM250 AM350 AM450 Applicable models Accessories /Options C C D -J -R AM550 AM650 AM850 Port size N.C. auto drain N.O. auto drain Accessories 06 3/4B 01 02 03 1/8B Drain guide 1/4B 10 14 20 1/4B 1B 11/2 B Options INOUT reversal 3/8B Element service
Options J: With drain guide M Mounting Dimensions Model Port Size (Nominal size B) A G F E D C B S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 R 4.5 5 5 5 5 9 9 10 12 Q 26 28 28 34 34 50 50 60 76 P 70 84 84 100 100 110 110 130 180 O 54 66 66 80 80 88 88 102 136 N 35 40 40 50 50 55 55 65 85 L 9 12 12 14 14 14 14 16 20 K 5 8 8 8 8 10 10 10 15 J 15 20 17 22 19 25 21 30 40 I 56 66 66 80 80 90 90 100
Symbol Order Made P.4.6-21 4.6-15 Micro Mist Separator with Prefilter Series AMH AMH150 to AMH850 How to Order AMH 250 03 J B Body size Options J Drain guide 1/4B female thread R IN/OUT reversal 150 1 8 250 1 4 350 3 8 450 1 2 550 3 4 650 1 850 11 2 Accessories(Options) Description None Bracket Symbol T Element service indicator B N.C.auto drain C N.O.auto drain D Note) Refer to p.4.7-7
140.5 LVR50-V19 22 80 120 169 C F E Breathing port M5 x 0.8 J Tube extensions 4 x 7 Mounting hole 1/8 (Rc, NPT) Pilot port A H D B G Breathing port M5 x 0.8 Model A B C D E LVR20-T07(06) 40 40 49.3 68 20.1 LVR40-T11(10) 82.5 82.5 89 115 33 IN C F Model F G H J K LVR20-T07(06) 8 27 56 33.5 126.2 LVR40-T11(10) 14 64.5 100 40 183.3 E K J J Breathing port M5 x 0.8 5 Applicable Fluids Regulator
Inlet pressure (MPa) 14-20-9 2 Series AFF How to Order AFF2B to AFF75B AFF 8B 03 J B Option Body size J Drain guide B female thread R IN-OUT reversal direction T Element service indicator 1 4 2B 4B 8B 11B 22B 37B 75B Standard 1 8 Standard 1 4 Standard 3 8 Standard 1 2 Standard 3 4 Accessory (Option) Symbol Description Bracket Nil B 1 Standard 11 2 Standard N.C. auto-drain C N.O. auto-drain
M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G S 6.0 , 2 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AMG850 1 2 13 42 348 220 57.5 220 10 14-20-7
M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G S 6.0 , 2 1 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AMH850 1 2 13 42 348 220 57.5 220 10 Please refer to Made to Order Specifications of Series AMH on pages 14-20-55 to 14-20-57. 14-20-35
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -
Please refer below for calculation of kinetic energy. 2 I 2 1 E E : Kinetic energy J I: Inertia moment kg/m2 : Angular speed rad/s Allowable kinetic energy for the rotary actuator is limited. The limit of rotation time is obtained by calculating inertia moment. Please refer following for obtaining inertia moment.
E : Kinetic energy J 2 I 2 1 E = : Angular speed rad/s I: Inertia moment kg/m2 Allowable kinetic energy for the rotary actuator is limited. The limit of rotation time is obtained by calculating inertia moment. Please refer following for obtaining inertia moment. Basic inertia moment 2 r m I = m : Weight of load (kg) r : Load center of gravity and distance of rotation axis.
90) Allowable kinetic energy (J) Size 10 20 30 50 0.007 0.025 0.2 to 1.0 0.048 0.081 Note) If operated where the kinetic energy exceeds the allowable value, this may cause damage to the internal parts and result in product failure.
F K A N NB lB H S + Stroke ZZ + Stroke Locking at rod end: MBBB Rl Bore size Stroke Locking at both ends: MBBB Wl Bore size Stroke Hl/Rl (mm) Width across flats Bore size (mm) Effective thread length Stroke range (mm) MM MB MA LL K J HN HR H GB G F E DL D lC lB A 32 40 50 63 80 100 up to 500 up to 500 up to 600 up to 600 up to 750 up to 750 19.5 27 32 32 37 37 M10 X 1.25 M14 X 1.5 M18 X 1.5
Series VXA31/32 Dimensions P port Bracket Pilot port Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J (Spanner flat) Port size P Port size Rc With bracket K 6 7.5 Symbol Model A B C D E F G H J M 14.5 17 L 29 32 1 8 1 4 VXA31 VXA32 19 25 20 20 18 21 20 20 22.5 27.5
Fluid Table (1) Rated Voltage-Electrical Entry-Electrical Option Standard specifications Option (1) Made to Order (2) Water (standard) Turbine oil High temperature water (D, E) Air X500B Vacuum (up to 1.3 x 10 2 Pa) X500B For pure water X500 G C Class B D, T Class H G, C T S Note) S L, Z L, Z S Note) Surge voltage suppressor is attached in the middle of lead wire.
Kit J Kit F Kit F L S The valve is equipped with an indicator light/surge voltage suppressor, and the voltage is 24 VDC. kit (Serial transmission unit) kit (Lead wire cable) The dust-protected type SI unit is applicable, too.
The product has a fan(s) and could cause serious danger to operators. 8.2 Specifications Cool outlet air (10oC) can be supplied.