For 3 stations For remote I/O A1W DeviceNet PROFIBUS-DP CC-Link 16 For 16 stations A2W 0 Without SI unit Stations Ports 1, 3, 5 position Symbol 02 Stations 2 stations Note U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 16 stations) Note 1) Double wiring specifications 08 02 8 stations 2 stations Note 2) Supply/Exhaust block assembly specification Specified
position One-touch fitting Effective area mm (Cv factor) Single/Double Double (Latching/ Double solenoid) Pressure center Exhaust center Series Closed center C3 C4 C8 C6 Dual 3 port valve (3.2) (4) (8) (6) Single SQ130 Metal seal SQ131 Rubber seal SQ230 Metal seal SQ231 Rubber seal 3.2 (0.18) 4.5 (0.25) 11.7 (0.65) 14.8 (0.82) 18 Series SQ1000/2000 How to Order Manifolds SS5Q 3 (-00T) JD0 1 08
Table 1 for applications.) 13 13 16 16 20 20 25 25 Table 1 Vacuum entry/Mounting thread diameter 32 32 Mounting thread diameter (male thread) 40 40 10 to 16 20 to 50 Pad diameter (mm) 50 50 M10 x 1 M14 x 1 Thread diameter, Piping diameter Connection A10 A14 Symbol M5 x 0.8 B5 Pad type Female thread Vacuum entry Rc(PT)1/8 B01 F Ball joint 4 tube 04 One-Touch fitting 6 tube 06 8 tube 08
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in8R 1/4-02-08AS2211FG-02-08-02-08-02-08
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in8R 3/8-03-08AS3211FG-03-08-03-08-03-08
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in8R 1/4-02-08AS2211FG-02-08-02-08-02-08
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in8R 3/8-03-08AS3211FG-03-08-03-08-03-08
Inch size Metric size 3.2 23 04 06 08 10 12 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 With One-touch fittings Use 1/8" tube. 2 Speed Controller with One-touch Fittings Panel Mount Type, In-line Type Needle Valve/Flow Characteristics AS1001F AS2001F AS2051F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (/min (ANR)) Flow rate
Note) Metric size 23 04 06 08 10 12 Inch size 3.2 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 Made to Order (For details, refer to page 622.)
./ Port size Connection Symbol A10 A14 B5 M5 x 0.8 Pad type B01 Rc 1/8 Female thread Vacuum entry F Ball joint type N01 NPT 1/8 T01 NPTF 1/8 04 4 tube Material One-touch fitting 06 6 tube N NBR 08 8 tube S Silicone rubber Tightening torque (N m) U Urethane rubber F FKM Torque Mounting thread dia.
Symbol Stations 02 08 2 stations 8 stations 2 stations 8 stations 1 3 2 D side U side Stations G: Flat ribbon cable (PC wiring, with power supply terminal) Symbol Stations 02 08 2 stations 8 stations SS3J3-V60PD2-06D 1 set (Manifold part no.)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, BASE MT, SY5000 SERIES, VALVE, SS5Y5 MANIFOLD SY5000, NJ, SS5Y5 BASE MT 1/8, 1.44428 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, BASE MT, SY5000 SERIES, VALVE, SS5Y5 MANIFOLD SY5000, NJ, SS5Y5 BASE MT 1/8
Peak/ Bottom value reset: A function to clear the peak value or bottom value when an external input signal is applied. 41 No.PF-OMU0002-D
Accumulated flow is selected: Refer to page 41 c. Accumulated pulse output is selected: Refer to page 42 d. Error output is selected: Refer to page 43 e. Output OFF is selected: Refer to page 43 Press the SET button to set. Return to function selection mode.
Width across flats of attachment 3/8 20.9 mm 1/2 23.9 mm 3/4 29.9 mm 1 41 mm 11/4 54 mm 11/2 54 mm After hand tightening the piping, apply a spanner of the correct size to the spanner flats on the product, and tighten it for 2 to 3 rotations. The tightening torque is shown in the table below.
Alternate signal Momentary signal*8 *8 Can be set when the setting of contact input signal 2 is "Run/Stop signal input" or "Remote signal" Contact input signal 2 delay timer of reading Setting and checking 41. Press the [SEL] key once. The set screen of contact input signal 2 delay timer of reading is displayed on the digital display.
Enabling/Disabling of AL27: CH2 electric conductivity increase alarm function (1) (2) (3) (4) Electric conductivity and alarm (AL27) setting HRL Series 5.4 Description of Screen 5-41 HRX-OM-W060 Chapter 5 Display and Setting of Various Functions Table 5.4-14 Settings of electric conductivity (AL27) No.
25 TEMP READY alarm (AL12) of TEMP READY function .5-27 Offset (TEMP OFFSET) function .5-30 Pump operation mode .5-32 Discharge pressure alarm (AL18/AL19/AL20) .5-34 Electric conductivity and alarm setting (AL28) .5-36 5.4.8 CH2 setting screen .5-37 Temperature rise/drop alarm (AL14/AL15) setting .5-38 TEMP READY alarm (AL16) and TEMP READY function .5-39 Offset (TEMP OFFSET) function .5-41
of TEMP READY function .5-26 Offset (TEMP OFFSET) function .5-29 Pump operation mode .5-32 Discharge pressure alarm (AL18/AL19/AL20) .5-33 Electric conductivity and alarm setting (AL28) .5-35 5.4.8 CH2 setting screen .5-36 Temperature rise/drop alarm (AL14/AL15) setting .5-37 TEMP READY alarm (AL16) and TEMP READY function .5-38 Offset (TEMP OFFSET) function .5-40 Pump operation mode .5-41