SMC Corporation of America
Elite Part Number Search
Search Results "PF3A702H-L3"

Center/Pressure Center [ ]: AC 3 4 5 G H 01 02 Grommet (G), (H): 10-SYJ7 4322 12 G: Approx. 300 H: Approx. 600 (Lead wire length) 122 [126.4] 36 [38.2] 2 x 4.3 (For mounting) B A 27 A B R1 R2 P Manual override 8.5 34 63.8 13.8 (Light/surge voltage suppressor) 1/4, 1/8 (P, A, B port) 57.5 [64.5] + 42.1 25.5 20 12 22 22 11.5 18 1/4 (R1, R2 port) 31.5 34 63 L plug connector (L): 10-SYJ7 43-L3

M1 Weight (g) 4 6 6 8 6 8 10 8 10 8 10 10 12 Applicable tubing O.D. d T H D1 D2 L1 L2 L3 Model AS121-M5-F04 AS121-M5-F06 AS221-01-F06S AS221-01-F08S AS221-02-F06S AS221-02-F08S AS221-02-F10S AS321-02-F08S AS321-02-F10S AS321-03-F08S AS321-03-F10S AS421-04-F10S AS421-04-F12S 16 17 17 18.5 17 18.5 21 18.5 21 18.5 21 21 22 13 13 34 31 54 50 52 86 81 93 88 154 146 21 21.5 25.5 26 M5 x 0.8 28.3

L1 L2 L3 L4 L5 L6 L7 (1) L8 D Model Bore size ASV AS2000-01 AS2000-02 AS3000-02, 03 1 8 Rc Rc Rc , 40 5 17 54.5 16 15.5 50 30 10 4.5 AK 1 4 1 4 2 x M4 x 0.7 11.5 17 56 51.5 40 5 23 20 30 4.5 Effective thread depth 6 Reference dimensions 8 3 45.5 5.25 20.6 61 13.2 68 56 25 26 5.5 VCHC Note 1) L7: Reference dimensions Dimensions: AS5000 ASR ASQ 2 x 1/4 to 1/2 2-1/4 to 1/2 74.9 (Max. 82.9)

L1 L2 A (2) L3 H (1) T2 T1 D1 D2 Model ASR ASQ AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS120-M5 M5 x 0.8 M5 x 0.8 8 10 28.3 10.3 9 9 25 22.2 25.5 AS120-U10/32 10-32UNF 10-32UNF AS220-01 30.5 13.2 14.3 14.6 32.4 27.4 12 (12.7) 18 35.5 1/8 1/8 AS220-02 35.3 17.5 18 19.5 34.8 29.8 17 (17.5) 27.2 40.3 1/4 1/4 AS320-03 40.8 19.7 22.5 24.3 40.6 35.6 19 30 45.8 3/8 3/8 AS420

CRB1 L1 L1 = L1 = L1 Q1 = M Q1 = M L1 = L1 MSU Q1 = M Q1 = M W1 = CRJ L1 = Q1 CRA1 CRA1 Q1 Q1 Q1 L1 K axis T axis J axis X axis CRQ2 X = [mm] [mm] L3 = L1 = Size Thread 30 50 63 80 100 M3 x 0.5 2.5 M5 x 0.8 4 4 M6 x 1 5 5 M8 x 1.25 6.8 6.8 6.8 M10 x 1.5 8.5 8.5 M12 x 1.75 10.3 10.3 Rc1/8 8 8 Rc1/4 11 Size Thread 30 50 63 80 100 M3 x 0.5 2.5 M5 x 0.8 4 4 M6 x 1 5 5 M8 x 1.25

VVPA460 Individual EXH: VVPA450Station 2Port size VVPA460Station 2Port size 34 2 x 18 Port size (1) Pilot port Pilot port 18 2 x 2 x SYA SYJA VZA VFA VFRA 4 x 13 Mounting hole VA 18 Pilot port 12 34 4n x , 34 2n x Port size (1) Port size (3/4, 1) L Dimension n n: Station Formula 2 257 10 953 7 692 8 779 9 866 3 344 4 431 5 518 6 605 Model L L1 VVPA450 L2 307 394 481 568 655 742 829 916 1003 L3

Load weight (kg) Caution The cylinder should be mounted in m1 orientation if maximum dustproofing is required. m m m Moment (Nm) M = F x L F3 M = F x L M = F x L F F2 L2 L1 L3 Maximum load weight Select the load weight from within the range of limits shown in the graphs. Note that the maximum allowable moment value may sometimes exceed even the operating limits shown in the graphs.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Piston speed V (mm/s) M2 = F2 x L2 ML1C/M2, M3 Moment (Nm) M3 = F3 x L3 Piston speed V (mm/s) (How to calculate the load ratio) A.

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series]

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)

Rated Flow Range: 10 to 1000 l/min, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -

Rated Flow Range: 10 to 1000 l/min, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: Yes, Flow Direction: -

Rated Flow Range: 5 to 500 L/min, Thread Type: Rc, Port Size: 1/2, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Option 1: -, Unit Specification: -, Option 2: -, Calibration Certificate: -

Rated Flow Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Option 1: -, Unit Specification: -, Option 2: -, Calibration Certificate: -

Rated Flow Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: SI Unit Only, Option 2: w/Bracket, Calibration Certificate: Yes

Rated Flow Range: 20 to 2000 L/min, Thread Type: NPT, Port Size: 3/4, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Option 1: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Unit Selection Function, Option 2: w/Bracket, Calibration Certificate: -

Rated Flow Range: 20 to 2000 L/min, Thread Type: NPT, Port Size: 3/4, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: w/Bracket, Calibration Certificate: Yes

Rated Flow Range: 20 to 2000 L/min, Thread Type: G, Port Size: 3/4, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: w/Bracket, Calibration Certificate: -

Rated Flow Range: 5 to 500 L/min, Thread Type: G, Port Size: 1/2, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Option 1: w/o Lead Wire and M8 Connector, Unit Specification: -, Option 2: -, Calibration Certificate: -

Rated Flow Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: SI Unit Only, Option 2: -, Calibration Certificate: -