Table Accuracy: High Precision, Size: 10, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable Length for
Table Accuracy: High Precision, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable Length for
Table Accuracy: High Precision, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable
Main Body Peripheral Component: Peripheral Components, Input Power Supply: AC Single Phase 100-115V, Position Detection: Incremental, Motor Type: AC servo motor (S2), Controller/driver type: Pulse input type / Positioning type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: AC Single-Phase 200-230V, Position Detection: Incremental, Motor Type: AC servo motor (S2), Controller/driver type: Pulse input type / Positioning type
How Grip: -, Number of Fingers: -, Open Dimension L1(mm): -, Closed Dimension L2(mm): -, Type: [Related Components] Tool Stand, Operation Method: -, Main Body Shape: -, Gripping Force (Closed Side at 0.5 Mpa)(N): -, Environment, Applications: -, Additional Function: -, Stroke Adjustment Mechanism: -, Cylinder internal diameter(mm): None, Finger position / Options: None, Auto switch: Without
How Grip: -, Number of Fingers: -, Open Dimension L1(mm): -, Closed Dimension L2(mm): -, Type: [Related Components] Tool Stand, Operation Method: -, Main Body Shape: -, Gripping Force (Open Side at 0.5 Mpa)(N): -, Environment, Applications: -, Additional Function: -, Stroke Adjustment Mechanism: -, Cylinder internal diameter(mm): None, Finger position / Options: None, Auto switch: Without
Oscillation Angle A: 310°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: Standard, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 0.22, Size: 10, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Standard cable, Actuator cable length(m): 1.5, Controller
Oscillation Angle A: 320°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 10, Size: 50, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Standard cable, Actuator
Oscillation Angle A: 320°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 1.2, Size: 30, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Standard cable, Actuator
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 250mm, Motor Option: None, Rod End Thread: M (Male), Mounting: L (Foot)
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 500mm, Motor Option: B (w/Lock)