bearing) (29) l2 = 50 mm V = 200 mm/s (30) l2 = 100 mm V = 200 mm/s MLGPL20/25 MLGPL20/25 10 10 25 25 25 20 25 20 20 Load weight m (kg) Load weight m (kg) Load weight m (kg) 20 25 20 25 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 20 1 10 30 31 100 101 200 300

LE-CSE-S;; is MR-J3ENCBL;M-A;-L manufactured by Mitsubishi Electric. LE-CSM-R;; is MR-PWS1CBL;M-A;-H manufactured by Mitsubishi Electric. LE-CSB-R;; is MR-BKS1CBL;M-A;-H manufactured by Mitsubishi Electric.

114.5 5 1.8 ;t M~e'l 'Iii 1'B e . , G U4(~1~) 13.5 5 1.8 D I' F f .F ,Holl, (s. ) \16 Ii" 15.5 7 <.~ 48 , 5 6 8 10 ~"" ) .. ~ : 1~.p ' 7 2$ 30 ZPY25D 25 28 20 ... fl tS12 a~ ~ .

length AMV Nil 30 50 0.6 m 3A 36 VJ10 110 VAC (with rectifier) 3 m 5 m AEP HEP How to order When requiring a vacuum switch with a lead wire of 5 m, indicate the part numbers of the vacuum unit switch without a lead wire connector and the 5 m lead wire connector separately.

Pin arrangement 4 3 3 Cable length Connector model S M L A B D 0.5 m 1.0 m 3.0 m M8-3 pin M8-4 pin M12-4 pin Note) L is available for the D-P4DW type only. Note) Type D is available for the D-P4DW type only.

M, Type V How to Order Reduced M 3 A IDG 03 30 purge IDG<A Series Made to Order Refer to page 33 to 44 for details.

30 50 51 300 200 Stroke (mm) Stroke (mm) 14 Series MGP Operating Range when Used as Stopper Bore Size: 12 to 25/MGPM12 to 25 (Slide bearing) MGPM12 to 25 (Slide bearing) L 50 mm L 50 mm L 50 mm 220 (100) 25 m m 110 (50) 20 88 (40) Mass of transferred object: m lbs (kg) 66 (30) 16 44 (20) 12 22 (10) When selecting a model with a longer L dimension, be sure to choose a bore size which

fitting C8 [3(R) EXH port] made by CONINVERS GmbH Circular connectors (26 pins) VQ 1/2 DIN rail clamp screw VQ 4/5 R R 3 3 60 AXT100-MC26-050: 5 m AXT100-MC26-030: 3 m AXT100-MC26-015: 1.5 m Circular connector cable assembly 40.5 X X B B B B B B B B 12 12 25 P P VQC 1/2 VQC 1/2 18 1 1 A A A A A A A A 18 VQC 4/5 18.5 (7.5) (12) 9.5 7.5 C3, C4, C6, M5 [4(A), 2(B) port] C3: 3.2 One-touch fitting

R A: 0.19 A P: 0.13 VP VG Grommet (G) Body Ported Base Mounted VZ300 VP S070 M5 x 0.8 0.66 2 3 (A R) VQ L plug connector (L) VKF (Standard) VQZ 100 VAC 50/60 Hz With surge voltage suppressor (G) (L) (M) (D) With light/ surge voltage suppressor (L) (M) (D) VZ500 200 VAC 50/60 Hz 24 VDC VZ VS 2.5 2 3 (A R) (Option) N. C. N. O.

[mm] Stroke [mm] 22 MGPK Series Operating Range when Used as a Stopper Bore Sizes 12 to 25 / MGPKFM12 to 25 (Slide bearing) MGPKFM12 to 25 (Slide bearing) L 50 mm L 50 mm 100 m m 25 50 40 20 Mass of transferred object: m [kg] 30 16 20 12 10 When selecting a model with a longer L dimension, be sure to choose a bore size which is sufficiently large. 4 5 Caution 3 Handling Precautions

ZY 6 4A 20 VJ10 6 10 15 20 25 30 0.6 m 5A 20 ZS ZF For ZSE3 1 m (For 100 VAC) 1.5 m Note) If ordering a vacuum switch with 3 m lead wire, specify both the vacuum unit switch and the 3 m lead wire with connector part numbers. Ordering example) ZX1051-K15LOECN(-Q) 1 pc. VJ10-20-4A-6 2 pcs.

Refer to the Specific Product Precautions. 20 Z ZZ (NN-1) x H G H 5.5 11 5.5 11 B A 3.2 6.5 7 7 12 1 4 NN x M4 x 0.7 thread depth 8 B A 3H9 depth 2.5 +0.025 0 3H9 depth 2.5 +0.025 0 HA GA Section AA Section BB (mm) GA 11 21 31 43 41 F 20 30 20 28 38 N 4 4 6 6 6 G 6 6 11 13 17 H 25 35 20 30 24 NN 2 2 3 3 4 HA 20 20 20 30 48 I 10 10 7 19 25 J 17 27 40 50 60 K 22.5 32.5 42.5 52.5 62.5 M 42 52

106.5 5.5 8 48 56 30 10 to 50,75,100 104 126 5.5 8 54 62 FT FX 40 B + Stroke 10 to 50,75,100 104 126 6.6 9 67 76 L FZ A + Stroke 2 x FD Bore size (mm) FZ L M 25, 30, 40 10 55 18 16 60 20 20 64 20 FV 25 65 22 34 30 72 22 40 FT FX 40 89 22 50 (mm) B + Stroke L FZ A + Stroke Bore size (mm) Stroke range (mm) 4 x FD REA A L 10 10 to 40 75 8 Head side flange type: MQQLG 10, 16, 20 25, 30, 40

For details about fixing method, refer to Wiring/Cables in the Electric Actuators Precautions. o Actuator cable length Nil Without cable 1 1.5 m 3 3 m 5 5 m 8 8 m* LER Nil: Left LEH LEY -X5 !0 Controller/Driver type*1 A 10 m* 11LEFS 11LEFS C 20 m* !

AXT100-FC26-2: 3 m AXT100-FC26-3: 5 m DIN rail clamp screw EXH R EXH R B B B B B B B B P X X P 49 31.6 24.5 9.5 16 A A A A A A A A (7.5) (12) C4, C6, C8 [4(A), 2(B) port] C4: 4 One-touch fitting C6: 6 One-touch fitting C8: 8 One-touch fitting P = 16 41 23 C10 [1(P) SUP port] C10: 10 One-touch fitting 2 L n Dimensions Formula L1 = 16n + 53, L2 = 16n + 68 n: Station (Maximum 24 stations) 3

AXT100-FC26-2: 3 m AXT100-FC26-3: 5 m DIN rail clamp screw EXH R EXH R B B B B B B B B P X X P 49 31.6 24.5 9.5 16 A A A A A A A A (7.5) (12) C4, C6, C8 [4(A), 2(B) port] C4: 4 One-touch fitting C6: 6 One-touch fitting C8: 8 One-touch fitting P = 16 41 23 C10 [1(P) SUP port] C10: 10 One-touch fitting 2 L n Dimensions Formula L1 = 16n + 53, L2 = 16n + 68 n: Station (Maximum 24 stations) 3

The total number of solenoids (points) must not exceed 24. 632 Base Mounted Plug-in Unit VQC4000 Series L VQC4000 Kit (Lead wire kit) IP67 compliant VV5QC41 L2 L1 48 6.5 SV Indicator light P = 25 65.5 Manual override SYJ A A A B A B A B A B A B SZ 9 9 A A A A A A A VF 143 163 VP4 74.5 Lead wire length: 0.6 m, 1.5 m, 3 m B B B B B VQ 1/2 10 n 1 2 3 4 5 6 7 Stations D side 8 U side VQ 4/5 3

M-type plug connector (M) P.2 (A) 2 M-type plug connector (M) Rubber Metal VQZ100 + 1 (P) 3 (R) N.O.

10 m, 15 m, 20 m Extension Cable (Option) Note 1) This includes the digital display error of the counter (CEU5).

Serial transmission) 0 1 2 With cable (0.6 m) Kit With cable (1.5 m) 2 rows of terminal blocks 3 rows of terminal blocks VQ2000 VQ1000 With cable (3 m) M S Type 24 16 Max. points Option 20 16 24 419 A VQ1000/2000 Series Semi-standard External Pilot Specifications DIN Rail Mounting Each manifold can be mounted on a DIN rail.