For detailed specifications, refer to page 10-20-1. 50 7 63 9 80 9.5 100 10.5 CV D-Z7/Z80 D-A3/A44 D-A3C, D-A44C D-A5/A6 D-B5/B64 D-A59W D-B59W D-Y5/Y6 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL D-F5/J5 D-F5W/J59W D-F5BAL/F5NTL D-F59F D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL D-G59F D-G39/K39 D-G39C, D-K39C MVGQ Electrical entry (Fetching direction) D-A53/A56 D-A64/A67 D-B64 D-Z80 D-F59/F5P/J59 D-F59W/F5PW/J59W
guide type) Data MY1H (High precision guide type) D-F9NW(V), D-F9PW(V), D-F9BW(V) Bore size (mm) Applicable cylinder series 16 20 25 32 40 10 50 63 80 100 MY1B (Basic type) MY1M (Slide bearing type) MY1C (Cam follower guide type) MY1H (High precision guide type) D-Y59 , D-Y69 , D-Y7P(V) A B A B Bore size (mm) Applicable cylinder series 16 20 25 32 40 50 63 80 100 MY1B (Basic type)
Its Mounting Height 12 to 25 32 to 100 D-A7 D-A80 12 to 25 32 to 100 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-F7NTL D-F7BAL 12 to 25 32 to 100 D-A73C D-A80C D-J79C 12 to 25 32 to 100 D-A79W D-F7WV D-F7V D-F7BAVL 32 to 100 D-A9V D-M9V D-F9WV D-A9 D-M9 D-F9W D-F9BAL 7-6-22 23 Compact Cylinder with Auto Switch: Standard Type Double Acting, Single Rod Series CDQ2 Operating Range
Series CHQWB B 32 to 100 D-A9 D-F9 D-F9W A B Approx.
Mounting Position (Detection at Stroke End) and Its Mounting Height B A U 32 to 100 D-A9 D-M9 D-M9W D-M9A D-A9V D-M9V D-M9WV D-M9AV 32 to 100 D-A7 D-A80 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-F7NT D-A73C D-A80C D-J79C D-A79W D-F7WV D-F7V U B A 32 to 100 D-P3DW U B A 40 to 100 D-P4DW B A U Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A72/A7H/A80H
D-F9P D-F9G D-F9H D-F9GL D-F9HL D-F9B D-F9NL D-F9PL D-F9BL N.O.
Height 12 to 25 32 to 100 D-A7 D-A80 12 to 25 32 to 100 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-F7NT D-F7BAL 12 to 25 32 to 100 D-A73C D-A80C D-J79C 12 to 25 32 to 100 D-A79W D-F7WV D-F7V D-F9W D-F9BAL D-A9 D-F9 D-A9V D-F9V D-F9WV 32 to 100 2.3-20 Compact Cylinder/Standard: Double Acting Single Rod Series CDQ2 Auto Switch Mounting Position (mm) D-F79W D-F7BA D-F7W D-F7F D-J79W D-F7WV
Mounting Auto Switch Proper Mounting Position (Detection at stroke end) and Its Mounting Height 32 to 100 D-M9l D-M9lW D-M9lA D-A9lV D-M9lV D-M9lWV D-M9lAV D-A9l A B U 32 to 100 D-A7l D-A80 D-A7lH D-A80H D-F7l D-J79 D-F7lW D-J79W D-F79F D-F7NT D-A73C D-A80C D-J79C D-A79W D-F7lWV D-F7lV U B A 32 to 100 D-P3DWA A B U Auto Switch Proper Mounting Position (mm) D-M9l/D-M9lV D-M9lW D-M9lWV
Bore size (mm) Auto switch model 32 40 50 63 80 100 D-A9/A9V D-M9/M9V D-M9W/M9WV D-M9AL/M9AVL BMB5-032 BMB5-032 BA7-040 BA7-040 BA7-063 BA7-063 D-A3/A44 D-G39/K39 BMB2-032 BMB2-040 BMB1-050 BMB1-063 BMB1-080 BMB1-100 CLJ2 D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5F D-F5BAL D-F5NTL CLM2 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 CLG1 CL1 The above figure shows the mounting example of D-A9(V)/M9(V)/M9W
50 mm 63 mm 80 mm 100 mm Only for D and T mounting types.
Its Mounting Height 12 to 25 32 to 100 D-A7 D-A80 12 to 25 32 to 100 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-F7NTL D-F7BAL Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 12 to 25 32 to 100 D-A73C D-A80C D-J79C 12 to 25 32 to 100 D-A79W D-F7WV D-F7V D-F7BAVL
Range (mm) (mm) Bore size Auto switch model Bore size Auto switch model 40 50 63 80 100 40 50 63 80 100 D-A9/A9V 7 9 9 9 D-F5/J5/F5W D-J59W D-F5NTL/F59F D-M9/M9V D-M9W/M9WV 4 4 4.5 4.5 4.5 6 4.5 5 5.5 5 D-Z7/Z80 D-G5/K59/G5W D-K59W D-G5NTL/G59F 8.5 7.5 9.5 9.5 10.5 5 6 6.5 6.5 7 D-A3/A44 D-A3C/A44C 9 10 11 11 11 D-A5/A6 D-B5/B64 D-A59W D-B59W D-G39/K39 D-G39C/K39C 9 9 10 10 11 D-P4DWL 4
Bore size (mm) 40 10 Auto switch model 50 63 80 100 D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5F/F5NTL BT-04 BT-04 BT-06 BT-08 BT-08 1 100 D-A3/A44 D-G39/K39 D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G59F D-G5NTL 1000 500 BDS-04M BDS-05M BMBI-063 BMBI-080 BMBI-100 Maximum speed (mm/s) (Example) Find the upper limit of rod end load when an air cylinder of 63 is operated at 500 mm/s.
(A contact) F9N F9P F9G F9H F9GL F9HL F9B F9NL F9PL F9BL D-F9N D-F9P D-F9G D-F9H D-F9GL D-F9HL D-F9B D-F9NL D-F9PL D-F9BL Lead screw lead N.C. (B contact) N.C. (B contact) N.C. (B contact) N.C. (B contact) N.O. (A contact) N.O. (A contact) N.O. (A contact) N.O. (A contact) 6mm 12mm A B Stroke 25 50 75 100 25mm 50mm 75mm 100mm Use a driver with CE marking.
(A contact) F9N F9P F9G F9H F9GL F9HL F9B F9NL F9PL F9BL D-F9N D-F9P D-F9G D-F9H D-F9GL D-F9HL D-F9B D-F9NL D-F9PL D-F9BL Lead screw lead N.C. (B contact) N.C. (B contact) N.C. (B contact) N.C. (B contact) N.O. (A contact) N.O. (A contact) N.O. (A contact) N.O. (A contact) 6mm 12mm A B Stroke 25 50 75 100 25mm 50mm 75mm 100mm Use a driver with CE marking.
IP63, JIS C 0920 Rainproof construction Except solid state switch with timer (D-M5TL, G5NTL/F7NTL/F5NTL) and magnetic resistant 2-color indication type solid state switch (D-P5DWL). D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
110 + 50 (n 2) n = 2, 4, 6, 8 55 + 50 (n2) n = 2, 3, 4 90 + 50 (n 2) n = 2, 4, 6, 8, 100 + 50 (n 2) n = 2, 4, 6, 8 Different sides D-A44 n Same side 10 20 100 90 100 110 100 100 110 100 100 110 1 Different sides 2 Same side D-A3C D-G39C D-K39C 100 + 35 (n 2) n = 2, 4, 6, 8 110 + 35 (n 2) n = 2, 4, 6, 8 20 + 35 (n 2) n = 2, 3, 4 100 + 35 (n 2) n = 2, 4, 6, 8 Different sides n 100
110 + 50 (n 2) n = 2, 4, 6, 8 Same side 15 90 100 110 35 100 100 110 100 1 Different sides 2 Same side 100 100 110 D-A3 D-G39 D-K39 35 + 30 (n 2) n = 2, 3, 4 100 + 30 (n 2) n = 2, 4, 6, 8 100 + 30 (n 2) n = 2, 4, 6, 8 110 + 30 (n 2) n = 2, 4, 6, 8 Different sides n 100 + 100 (n 2) n = 2, 4, 6, 8 110 + 100 (n 2) n = 2, 4, 6, 8 100 + 100 (n 2) n = 2, 3, 4 Same side 100 100 110 90 100
Auto Switch Made to Order 100 C85/C75 Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at stroke end) and Mounting Height Applicable series: CD85l Double acting/Single acting: Rail mounting Double acting/Single acting: Band mounting D-M9l D-M9lW D-M9lA D-A9l D-M9l D-M9lW D-M9lA D-A9l 17 Hs Hs Hs Hs Hs Hs Hs Hs Hs Hs B A B A D-M9lV D-M9lWV D-M9lAV D-A9lV
, D-C8 20 to 63 D-G5, D-K5, D-G5W, D-G5BAL D-K59W, D-G59F, D-G5NTL = ~ Hs Auto switch Auto switch = ~Hs D-M9, D-M9W, D-M9A 20 to 63 D-C73C, D-C80C 20 to 63 Auto switch = ~ Hs Auto switch = ~Hs D-B5, D-B6, D-B59W 20 to 100 Auto switch = ~ Hs Proper Auto Switch Mounting Position Auto Switch Mounting Height D-G5W D-K59W D-G59F D-G5 D-K5 D-G5NTL D-G5BAL D-G5NTL D-G59F D-G5BAL D-B5/B6 D-B59W D-G5