Apparent power (VA) Volt-ampere is the product of voltage (V) and current (A). Power dissipation (W): For AC , W = V/A cos. For DC, W = V/A. (Note) cos shows power factor. cos = 0.6 2. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. 3.
(2-color indicator) 2-wire 12 V 24 V Grommet Yes Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V 2-wire 12 V 3-wire (NPN equivalent) Reed auto switch 5 V Z76 IC circuit Yes Grommet 100 V Z73 IC circuit Relay, PLC 24 V 12 V 2-wire Z80 100 V or less Lead wire length symbols: 0.5 m Nil (Example) Y7BW 3 m L (Example) Y7BWL 5 m Z (Example) Y7BWZ Solid state auto switches marked
Connect the motor power supply input terminal (U, V, W) to the driver power terminal (U, V, W).
Solid state switch Model D-F8 Series Variations Bore size (mm) Rod end configuration Stroke (mm) Clean room series 4 6 8 10 15 20 Action Series Auto switch Double acting Male thread Without thread Nil 4 Single acting (spring return) Double acting 6 Single acting (spring return) CUJ Solid state switch D-F8 D-F9 Female thread Double acting 8 Male thread Single acting (spring return) Double
l Cross section C-C #i .. :: fl ffi -i+-sLJ rr Model D f G, I K L !,!
Electrical entry Normally closed Normally open Double acting VNA01 VNA02 VNA03 VNB Coil rated voltage (V) AC (50/60 Hz) 100 V, 200 V, Other voltage (Semi-standard) 24 V, Other voltage (Semi-standard) 15% to +10% of rated voltage 35C or less (When rated voltage is applied.) 5.6 VA (50 Hz), 5.0 VA (60 Hz) 3.4 VA (50 Hz), 2.3 VA (60 Hz) 12.7 VA (50 Hz), 10.7 VA (60 Hz) 7.6 VA (50 Hz), 5.4 VA
C c OFF OFF OFF ON OFF D d OFF OFF OFF OFF ON E E OFF OFF OFF OFF OFF The control power supply turn off Turn on the power again When multiple alarms in alarm groups A to D occur, the relevant OUT0 to OUT3 will be ON.
Screwdriver 5 to 6 Switch mounting screw M2.5 X 4 l Hysteresis Auto switch Switch operating position (ON) Switch reset position (OFF) Max. hysteresis mm Auto switch D-F9BAL D-F9N(V) F9B(V) ON: Red light emitting diode Model ON: Green light emitting diode Note) Use a screwdriver with a grip diameter of 5 to 6mm to tighten the auto switch mounting screw.
Stations 02 03 2 stations 3 stations Station 3 2 1 D side U side 20 20 stations Note) Maximum of 20 stations Electrical entry Grommet/Plug lead C How to Order Valves S070 A 5 B G Electrical entry Body type Body type Base mounted with clips G C Grommet Plug lead with light/surge voltage suppressor Symbol A Coil voltage Power consumption Pressure specification Flow rate 5 6 V S R 24
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) When 2 auto-switches are specified they are assembled for shipping.
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) This product can be mounted on the NEXTAGE KAWADA ROBOTICS CORPORATION. 3-2.
Operating temperature 32 to 104F (0 to 40C) Material Conductive nylon + Flame resistant nylon (Equivalent to UL-94 Standards V-0) Surface resistance 104 to 107 Hardness Shore D 48 Note 1) Refer to the burst pressure characteristics and operating pressure curve for other temperatures. Avoid abnormal temperature rises due to adiabatic compression.
as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 73 Circulating Fluid Temperature Controller
output + Analog current output V V V + b ITVH With digital pressure switch ITVX c Flow direction Nil Flow direction: Left to right V V V R Flow direction: Right to left V V V + PVQ Semi-standard VY1 d Knob Nil Upward V V V V Downward V V V + u VBA VBAT e Pressure unit Note 3) Nil Name plate and pressure gauge in imperial units: MPa V V V Z Name plate and pressure gauge in imperial units:
ED NPN open collector 1 output + Analog current output V V V + b With digital pressure switch ITVX PVQ c Flow direction Nil Flow direction: Left to right V V V R Flow direction: Right to left V V V + VY1 Semi-standard d Knob Nil Upward V V V V Downward V V V + VBA VBAT u AP100 e Pressure unit Note 3) Nil Name plate and pressure gauge in imperial units: MPa V V V Z Name plate and pressure
Model Wiring NPN transistor (open collector output) CEU5 50 mA or OUT less CEU5B Load Power CEU5-D COM (30VDC or less) CEU5B-D PNP transistor (open collector output) CEU5P (50 mA or less) OUT CEU5PB Load Power CEU5P-D COM (30VDC or less) CEU5PB-D 6-5.
A Input/output specifications 22 30 62 70 NPN open collector 2 output + Analog output Bracket D NPN open collector 2 output + Auto shift input Refer to the dimensions for the difference between brackets A and D. D PNP open collector 2 output + Analog output PNP open collector 2 output + Auto shift input Optional Note) Auto shift input is used for the auto shift function.
Basic type Pilot Solenoid Valve Specifications VEX5511/5711/5911/5501/5701/5901 SF4--20 Grommet (G), Grommet terminal (E), Conduit terminal (T), DIN terminal (D) Pilot valve Model Electrical entry Coil rated voltage (V) AC (50/60Hz) DC Allowable voltage 100 V, 200 V, Other (Option) 24 V, Other (Option) 15 to +10% of rated voltage Inrush AC Holding DC 5.6 VA (50Hz), 5.0 VA (60Hz) 3.4 VA (50Hz
Wiring table for power supply cable IZS30-CP Pin Lead wire color Description Function 1 Brown DC21.6 to 26.4V Power supply DC + 24 V 2 Blue GND Power supply 0V. Be sure to apply class D grounding. 3 Green NC 4 Gray Stop signal of static charge elimination Connected 0V during operation.
7) 0V [1] Power supply input terminals, L1 and L2: Specify power supply to input terminals L1 and L2. [2] Connect the motor power supply input terminal (U, V, W) to the driver power terminal (U, V, W).