This is a legacy product, and replaced byCP96SDB32-20C, C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, LE, 32MM C95/CP95 DBL-ACT AUTO-SW, 2.34845 lb
1800 IR Bowl capacity (cm 3) 440 Recommended lubricant Turbine oil Class 1(With no additives), ISO VG32 VEX Ambient and fluid temperature 5 to 60C (No freezing) Bowl material Polycarbonate AMR Weight (kg) 1.62 1.67 Bowl guard Accessory (Standard) ITV Note) Conditions: Inlet pressure = 0.5 MPa, Number of drop = 5 drops/min, Turbine oil Class 1 (with no additives) ISO VG32, Temperature = 20C
Series DXT474 Environment How to Calculate Flow Rate (At an air temperature 20C) Subsonic flow : P1+0.1013<1.89(P2+0.1013) 1 Do not use in atmospheres where the valve is in direct contact with corrosive gases, chemicals, salt water, water or steam. 2 Do not use in an explosive atmosphere. 3 Do not use in a place subjected to heavy vibration and/or shock.
Port Solenoid Valve 3 Port Solenoid Valve Power Consumption (with power saving circuit) Temperature rise: 1C (with power saving circuit) V100 Specifications V100 Specifications V100 Specifications V100 Specifications Type With power saving circuit Standard Valves of specific power consumption can be manufactured to suit the f f f p f p p Power Consumption 0.1W 0.35W Temperature rise 1.0C 20C
(Coil temperature: 20C, pressure: 0.5 MPa, at rated voltage, with light and surge suppressor, value at operation excluding restart period) The period immediately after a restart may be delayed for about 1 msec depending on operating conditions. Note 2) Use dry air to prevent condensation when operating at low temperatures.
capacity (cm 3) 380 (Capacity between levels 350) Turbine oil Class 1(With no additives), ISO VG32 Recommended lubricant 5 to 60C (No freezing) Polycarbonate Ambient and fluid temperature Bowl material 1.56 1.78 Weight (kg) Bowl guard Accessory (Standard) Note) Conditions: Inlet pressure = 0.5 MPa, Number of drop = 5 drops/min, Turbine oil Class 1 (with no additives) ISO VG32, Temperature = 20C
(mm) ASG32F-01 4 ASG42F-02 6, 8 ASG52F-03 6 ASG62F-04 Sealant: Special FKM Seat ring: Stainless steel 303 8 12 4, 6 8, 10 10, 12 Flow rate (l/min (ANR)) 460 790 920 1580 100 180 230 390 Controlled (free) flow 7 12 14 24 1.5 2.7 3.5 6 Effective area (mm2) Applicable tubing materials Note) Flow rate is measured at 0.5 MPa and 20C.
AK 100 130 230 290 660 920 Controlled flow Body A Free flow Sonic conductance [dm3/(sbar)] 0.28 0.36 0.64 0.8 1.8 2.6 VCHC Controlled flow Free flow 0.2 0.25 0.2 0.25 0.2 0.25 0.2 0.25 Critical pressure ratio Caution Release from One-touch fitting ASR ASQ Note) Flow rate values are measured at 0.5 MPa and 20C.
Metric size 4 4 6 Controlled flow Free flow Critical pressure ratio 180 230 260 390 460 660 790 920 1580 1710 Flow rate (L/min (ANR)) Symbol 0.5 0.64 0.72 1.1 1.3 1.8 2.2 2.6 4.4 4.8 Sonic conductance dm3/(sbar) 0.25 0.3 0.25 0.25 Controlled flow Free flow 0.2 0.3 0.2 0.3 Note) Flow rate values are measured at 0.5 MPa and 20C.
conductance dm3/(sbar) 1/4 3/8 1/2 3/4 1 1 1 10 3,600 4,800 6,700 8,100 16,900 38,500 47,500 60,800 AS420-02 AS420-03 AS420-04 AS500-06 AS600-10 AS800-12 AS900-14 AS900-20 2,500 5,000 6,600 6.9 13.9 18.3 28.1 42 98 144 161 0.34 0.33 0.32 0.36 0.7 1.4 3.3 3.3 13.3 18.6 22.5 47 107 132 169 10,100 15,100 35,400 52,000 57,800 0.45 0.25 1 4 1 2 2 Note) Flow rate values are measured at 0.5 MPa and 20C
AS221FE-01 AS231FE-01 AS221FE-02 AS231FE-02 AS321FE AS331FE AS421FE AS431FE Model 8 10 6 8 10 12 12 10 6 8 10 Tubing O.D. 4 6 Metric size 4 230 260 390 460 660 790 920 1580 1710 Flow rate (/min (ANR)) 180 Controlled flow (Free flow) Flow Direction Symbols on Body Effective area (mm2) 2.7 3.5 4 6 7 10 12 14 24 26 Meter-out type Meter-in type Note) Flow rate values are measured at 0.5 MPa and 20C
M3 x 0.5 20 0.06 20 0.06 4.7 0.15 M5 x 0.8 90 0.25 80 0.22 33 1/8 340 0.94 250 0.7 90 1/4 340 0.94 250 0.7 115 1/4 810 2.3 810 2.3 130 3/8 810 2.3 810 2.3 124 0.2 1/4 1,670 4.6 1,670 4.6 221 0.35 3/8 1,670 4.6 1,670 4.6 214 1/2 1,670 4.6 1,670 4.6 205 1/4 2,840 7.9 2,840 7.9 242 3/8 4,270 11.9 4,270 11.9 233 1/2 4,270 11.9 4,270 11.9 224 Note) Flow rate values are measured at 0.5 Mpa and 20C
temperature Round lock nut With seal, Round lock nut, Nickel plated Option 181 106 64 29 10 6 3 Weight (g) 230 105 20 1700 920 460 Flow rate L/min (ANR) Controlled flow Free flow Sonic conductance dm 3/(sbar) 0.7 0.32 2.8 1.4 0.06 5.2 Critical pressure ratio Controlled flow 0.25 0.2 0.3 0.2 0.25 0.25 Free flow 0.4 0.3 0.2 0.4 0.3 0.2 Note 1) Flow rate values are measured at 0.5 MPa and 20C
foot for fixing) Weight Accessories Power cable, Foot for fixing CE marking, UL (NRTL) standards CE marking, UL (NRTL) standards, Safety standard for medical equipment (IEC 60601-1) Safety standards Note 1) Conditions: Set temperature 77F (25C), Ambient temperature 77F (25C), Circulating flow rate 0.79 gpm (3 L/min) Note 2) Conditions: Set temperature 77F (25C), Ambient temperature 68F (20C
(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) Accessory (Option)/Replacement Parts Applicable model ID20 ID30 ID40 ID60 6604113 6604113 660651 660651 ID-200S ID-300S ID-400S ID-600S ID-200Z ID-300Z ID-400Z ID-600Z ID-DPM8 Bracket Adsorbent set Note) Adsorbent set (for low dew point) Note) Indicator set Note) Adsorbent and adsorption tube filter for one air dryer (two adsorption
Note 3) Do not cut the tube. 1 Use the product in an operating environment where humidity is as low as possible. 2 The value at which the moisture control tube is bent or flattened at 20C. Be careful not to bend or flatten the tube and the inner sleeve even if the value is more than the minimum bending radius. 2 Inner sleeve R How to Order IDK 02 100 Moisture control tube O.D.
Air consumption Note 3) 18 L/min (ANR) or less (SUP = 0.5 MPa) Note 1) Specification values are given at normal temperature (20C). Note 2) Characteristics relating to accuracy differ depending on combination with other constituent loop equipment, such as positioners and actuators. Note 3) Air consumption is due to exhaust from nozzle. And (ANR) indicates JIS B0120 standard air.
Low clamping torque Specifications Gap (approx. 0.5mm) Applicable tube material Polyurethane Applicable tube dia. 2/1.2 1MPa Max. operating pressure (at 20C) 4. Insert the sleeve slowly. Make sure not to allow any gap between the sleeve end side and the body end side. (Please refer to the illustration below.)
Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple 1% or less) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output Maximum transmission distance Position detection method Magnetic field resistance Power supply Current consumption Resolution Accuracy Output type Output signal Insulation resistance Vibration resistance Impact resistance Enclosure
40mm, Double acting and Single acting available, Auto switch capable, Improved rigidity of guide rail, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, HT, 20MM MHZ2, .55115 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalSingle actingNormally closedMHZ2-20C