SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20C-T-02"

Style: Pressure Switch w/ T-Spacer, Body Size: 20 (AC20), Thread Type: N (NPT), Port Size: 02 (1/4), Set Pressure Range: 6 (0.1 to 0.6 MPa), Lead Wire Length: 0.5m, Pressure Unit of the Scale Plate: P (MPa/psi Dual Scale)

Style: Pressure Switch w/ T-Spacer, Body Size: 30 (AC30), Thread Type: F (G), Port Size: 02 (1/4), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: 0.5m, Pressure Unit of the Scale Plate: MPa

[] 14096 X (1) ()1 ()1 11 800 1 (2) ()1 ()2 1600 1 (3) ()2 ()1 400 1 ()1 ()1 0 1 4097 4096 1 2 1 [] 1 LEY16C-300 2.5mm 1/1 2 LEY16B-300 5mm 25/50 3 LEY16A-300 10mm 25/100 14096 X 12 1 800 2.5mm 2 3 =1 /2 3 =2.5mm/5mm (2.5mm/10mm) =25/50 (25/100) 1) 50 No.SFOD-OMT0009CN-B 7.3 XX X 1CW X 1 2 2CCW 1 XX 1 2 2 1) XX 1) XX 1) XX 0 XX 02 1a 2b 21 1)

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Type of actuation (With gasket and screws) 1 2 Normally closed Normally open Manual override Coil specification Nil 0.35 W 0.1 W (With power saving circuit) (24 VDC, 12 VDC only) Nil: Non-locking push type T All the types with power saving circuit are

Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)

Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)

5 u t !8 @1 r @4 w 12 to 40 @7 !1 !7 q !6 !0 @2 @3 o @4 @6 y e r !8 @1 @5 u w Rod cross section for 12, 16, 20, and 25 Rod cross section for 32 and 40 With end lock 12 to 40 y !7 !6 q !0 o @2 @3 @4 @6 e r !8 @5 @1 i @8 !4 !5 !2 @9 !3 w Parts list No. 1 2 3 4 5 No. Description Rod cover Head cover Cylinder tube Piston Spacer for switch type Description Qty. Note Material Qty.

Panel adapter B ZS-22-02 NPN open collector 2 outputs PNP open collector 2 outputs 0 1 Specifications Model PFW300 PFW301 PFW310 PFW311 PFW321 PFW320 Flow rate measurement and setting range Minimum setting unit 0.5 to 4 (setting is 0.6 to 4) l/min 2 to 16l/min 5 to 40l/min 0.1l/min 0.5l/min 0.05l/min Real-time flow rate l/min, gal (US)/min Accumulated flow Display units Note 1) l, gal (US

Exchange the order of 2 wires out of the 3 wires (R phase and T phase) and reconnect them. External switch for remote operation has not been turned ON. Turn on the switch. Wiring for remote operation is loose or keeps coming out. Connect the wiring correctly. The lamp goes off and the compressor stops. Water-cooled condenser is contaminated. Clean the air-cooled condenser.

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROL, 1/8 NPT H/T, AIRLINE EQUIPMENT, AS FLOW CONTROL, CD, AS 1/8INCH STANDARD (NPT), .19841 lb

Body Size: 30, Thread: N (NPT), Port Size: 02 (1/4), Option: DG (D + G), Attachment: TV (T + V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: Rc, Port Size: 02 (1/4), Option: CG (C + G), Attachment: TV (T + V), Semi-Standard 1: Standard, Semi-Standard 2: Standard

Body Size: 20, Thread: Rc, Port Size: 02 (1/4), Option: C (N.C. Float Type Auto Drain), Attachment: TV (T + V), Semi-Standard 1: Standard, Semi-Standard 2: Standard