SMC Corporation of America
Elite Part Number Search
Search Results "VV5FR3-10-101-03"

Hysteresis 0 to variable 7 Withstand pressure 600 kPa Detection nozzle 1.5 4 Current flow 5 L/min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple(p-p) 10% or less (with power supply polarity protection) Current consumption 25 mA or less Switch output 2 output (NPN or PNP) Max. load current 10 mA Max. applied voltage 26.4 V Residual voltage 1 V or less (at

/CLR, number of stations occupied and mode are performed with SW2. 10 9 8 7 6 5 4 3 2 1 ON ON Station number setting (Switch No.1 to 7) Set tens digit of station number 10, 20 and 40, and set ones digit of station number 1, 2, 4 and 8.

x 1.5 23 100 1/2 21 130 40 204 4 End Lock Cylinder Series CBG1 With front lock: CBG1BN Bore size Stroke R GB (mm) Bore size (mm) DL1 GB S TB ZZ 20 19.5 10 (12) 80 (88) 11 117 (125) 25 19.5 10 (12) 80 (88) 11 122 (130) 32 20 10 (12) 81 (89) 10 (11) 123 (131) 40 19 10 (13) 87 (96) 10 (12) 139 (148) 50 23.5 12 (14) 102 (114) 12 (13) 162 (174) DL1 63 23.5 12 (14) 102 (114) 12 (13) 162 (174

Grease pack (10 g) 1 pc. IN 84.8 59 42 25 CQSY16-PS 12 6 OUT 113 79 57 34 CQSY20-PS IN 151 106 75 45 CQSY25-PS 16 8 OUT 201 141 101 60 When only grease for maintenance is necessary, please order by the following part numbers.

{Rc3/8} FGH200-03 {Rc3/8} FGH300-03 {Rc3/8} FGH200 Series FGH300 Series 0.05 0.05 0.05 Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) 0.01 0.01 0.01 0.005 0.005 0.005 0.001 10 30 50 70 100 0.001 10 30 50 70 100 0.001 10 30 50 70 100 Flow rate (L/min) Flow rate (L/min) Flow rate (L/min) FGH100-04 {Rc1/2} FGH200-04 {Rc1/2} FGH300-04 {Rc1/2} 0.05 0.05 0.05 Pressure drop (MPa) Pressure

If an instantaneous flow of 10 L/min continues for 5 minutes, the accumulated flow will be 10 5=50 L. Accumulated flow external reset A function to reset the accumulated flow to zero by using an external signal. Accumulated pulse output A type of output where a pulse is generated every time a predefined accumulated flow passes.

15 20 25 30 ( 30 10 XL-OMY0002 . 1 S 12 ( SUS304 M 3 M SUSU316L 8 11 SUS304 2 7 A6063 6 9 6 9 10 9 5 SUS304 4 5 10 4 10 S O S O XLD-25 XLD-40,XLD-50,XLD-160 XLD-63,XLD-80,XLD-100 S 1 SUS304+ 4 1) S S O 2) S O FKM 5 O 6 S O 2 FKM 9 S SUS304 10 11 XL-OMY0002 6. 6-1.

L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L Fig. 9 Position for application of grease Table 10 Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 20 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig.9, ) Pay attention to the mounting direction of the seal.

(V) 24 Allowable voltage fluctuation -10 to 10% Power consumption (W) 0.4 [Starting 0.4, Holding 0.1] Please refer to page 1367 of Surge voltage suppressor the Best pneumatics catalogue.

Length TH0402 TJG-0402 18 4 TUS0425 TH0425 TJG-0425 18 TL0403 TJG-0403 18 6 TUS0604 TH0604 TL0604 TJG-0604 19 8 TUS0805 TJG-0805 20.5 TH0806 TL0806 TJG-0806 20.5 TUS1065 TJG-1065 23 10 TH1075 TJG-1075 23 TH1008 TL1008 TJG-1008 23 TUS1208 TJG-1208 24 12 TH1209 TJG-1209 24 TH1210 TL1210 TJG-1210 24 *Stainless steel 316 is used for the TJG series. 10 - Cross Reference Table of the Inner Sleeve

If it is 10 L/min, there is a flow of 10 L passing through the device in 1 minute. The voltage drop across the product (and therefore not applied to the load), when the switch output is ON. The voltage drop will vary with load current, and ideally should be 0 V.

MY1B16100 MY1M1663 MY1C1663 MY1H1640 MY1B25,32,40-Z MY1H25,32,40-Z Fig. 10-a -13- Applicable cylinder Port variations MY1HT50,63 MY1MW16,20,50,63 MY1CW16,20,50,63 MY1MW25,32,40 MY1CW25,32,40 Fig. 10-b Refer to Table 2 below for the dimensions of mating parts when bottom ported. Please consult SMC for ordering seals.

AS568-030-XN1 Note2) Refer to Chapter 4, Construction and Dimensions" (P. 10) for the part indication numbers.

Detection nozzle: 1.5 Piping: F type: 4 x 2.5 tube 1 m, 3 m, 5 m Test conditions G, H type: 6 x 4 tube 1 m, 3 m, 5 m Supply pressure: 200 kPa ISA3-F ISA3-G Piping length: 1m, 3m, 5m Piping length: 1m, 3m, 5m : When the display value becomes 9 or lower, "0" is displayed. "0" and "10" are displayed near "10". This does not affect the performance.

Other dimensions are same as grommet type. 10 9 107 101 8 96.5 90.5 7 86 80 6 75.5 69.5 5 65 59 4 54.5 48.5 3 44 38 20 stations Station L1 L2 2 stations 33.5 27.5 11 128 122 12 13 149 143 14 15 170 164 16 17 191 185 18 19 212 206 117.5 138.5 159.5 180.5 201.5 222.5 111.5 132.5 153.5 174.5 195.5 216.5 4-2-9 10 Series V100 Specific Product Precautions 1 Be sure to read before handling. 3.

DC24V10% DC24V 10% DC(+) DC(-) 8 / / 9 ( ) 10 , 5 m / / 11 1015 10 "-M" (kPaMPa) ( ) "M" 12 SI kPa,MPa 48 - No. 13 14 () 15 () / ( ) () 49 - 80mA 3.5 F.S.1 1F.S. 50 - 100.0-100.0 kPa 105.0-105.0 kPa 500 kPa 0.1 kPa DC24 V 10(p-p)10() 40 mA NPN PNP OUT1OUT2 80 mA DC26.4 V 2 V (80 mA ) 2.5 ms (20,100,500,1000,2000 ms ) 0.2F.S.1 digit 1 0 3 1/2 7 LED () 2% F.S

Reference Heavy duty auto drain 6.3 Outer dimensions [IDF100F-30-W] Ball valve (O.D.10, Length approx. 2m) is also available.)

, 2m) ) 4 (10 4x ( 20 4x 25 2m) (10, 0.7m) (10,0.7m) 107 267 460 R2 735 64 75 7001 1120 R2 (17) 17) 40 127 479 51 1276 1418) (14~18) 1375 1,3 -W4 -W4 (-W4) (-W4) Y1/2 Y 1/2 () () R1/2 R1/2 (50) 20 (143) 335 7122 752 670 1,3 (-W5) -W5 -W5 (-W5) R1/2 R1/2 IDF100F150F-W 6 3 IDX-OM-Z004 6 IDF125F-30-W () K16K (10, 2m) (10 ) ( 4 4x JIS 65A 10K (K16K) 2m) 20 JIS 65A 10K

R . 10-1 10.1 . 10-1 10.2 . 10-1 10.3 . 10-2 11 T . 11-1 11.1 . 11-1 11.2 . 11-1 11.3 . 11-2 11.4 . 11-3 11.5 . 11-4 12 V . 12-1 12.1 . 12-1 12.2 . 12-1 12.3 . 12-2 13 . 13-1 13.1 . 13-1 IDFC60/70/80/90 Series IDX-OM-W095 1 1.1 () 6.2 1.1.1 3 IDFC60/70/80/90 Series 1-1 IDX-OM-W095 1.2 6 1.2.1 1.2.2 50 1.2.3 0 IDFC60/70/80/90 Series 1-2 IDX-OM-W095 1.2.4 IDFC60/70/80

Scale indication range Connection thread size M5 0~8 1/8 0~10 1/4 0~10 3/8 0~10 Connection Chamfer dimensionD(Recommended value) thread size 1/2 0~10 M5 5.15.4 The scale indication range is also printed on the product. 10-32UNF 5.05.3 (5) Tubing outside diameter (O.D.) of (6)-2 For R, NPT, G thread Tightening method Scale indication range When installing the connection thread, tighten it