DIMENSIONS (Accessory) (Port size) Maintenance space Drain Dimensions Model Standard specifications 1/81/4 1/43/8 1/43/81/2 3/4 , AFM20-A 40 87.6 9.8 20 45 AFM30-A 53 115.1 14 26.7 30 50 AFM40-A 70 147.1 18 35.5 38.4 75 AFM40-06-A 75 149.1 20 35.5 38.4 75 Model Bracket mount dimensions AFM20-A 30 27 22 5.4 8.4 40 2.3 28 AFM30-A 41 35 23 6.5 13 53 2.3 30 AFM40-A 50 52 26 8.5 12.5 70 2.3
Series 10-MGF Guide table 40, 63, 100 How to Order 10 M G F 63 50 Y59B Number of auto switches 2 pcs. 1 pc. 10 Clean series Relief type Nil S Bore size (mm) Reed switch Type of auto switch Port type Z73 Solid state switch Y59A,Y59B Bore size Type Rc NPT G Symbol Nil TN TF 40, 63, 100 Cylinder stroke (mm) Model Cushion Bore size (mm) 40 63 100 Standard stroke (mm) Auto switch mounting Action
Maximum suction flow (l/min(ANR)) Air consumption (l/min(ANR)) Maximum vacuum pressure (kPa) Maximum vacuum pressure (kPa) Maximum vacuum pressure -80 -80 60 -60 -60 50 40 -40 -40 30 Air consumption 20 -20 -20 10 Maximum suction flow Suction flow (l/min(ANR)) 25 20 15 10 5 0 0.1 0 0.2 0.3 0.4 0.5 0.6 Supply pressure (MPa) 13-9-3 4 Series ZQ Specifications Ejector Weight Switch and suction
switches mounted 2 Max. manufacturable stroke (mm) Bore size (mm) 20 25 32 40 Standard stroke (mm)(1) Model Long stroke (mm) 1 201 to 350 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200 Data D-C7/C8 D-B5/B6 D-H7 D-G5NTL 1500 10 mm 15 mm 25, 50, 75, 100, 125, 150, 200, 250, 300 15 mm 20 mm Note 1) Intermediate strokes other than the above are produced upon receipt of order.
AWD30, 40 w w t t q q IN OUT IN OUT e y y e r u r u Drain Drain Component Parts No.
AWD30, 40 w w t t q q IN OUT IN OUT e y y e r u r u Drain Drain Component Parts No.
(2B) JIS 10K FF flange 30 80(3B) JIS 10K FF flange 40 100(4B) JIS 10K FF flange 2) Specifications Table. 2 Specifications Note) Max.flow at 0.7MPa.
cores) Brown Blue Flat cable AWG28 With power lines Without power lines Model PCW-9930661H PCW-9903491H 20 cores 40 cores 20 cores 34 cores 40 cores Flat cable AWG28 (7 wires/0.127 mm) Length 100 m roll Power lines AWG20 (21 wires/0.18 mm) Sheath O.D. 10.3 mm 12.0 mm 8.7 mm 11.8 mm 13.0 mm Note) The flat ribbon cable without power lines are not available from P/A.
0.3 0.4 0.5 0.6 Suction flow (l/min(ANR)) Supply pressure (MPa) ZQ110 Exhaust characteristics ZQ110 Flow characteristics Maximum suction flow (l/min(ANR)) Air consumption (l/min(ANR)) Maximum vacuum pressure (kPa) Maximum vacuum pressure (kPa) Maximum vacuum pressure -80 -80 60 -60 -60 50 40 -40 -40 30 Air consumption 20 -20 -20 10 Maximum suction flow Suction flow (l/min(ANR)) 25 20 15
DIMENSIONS (Accessory) (Port size) Maintenance space Drain Dimensions Model Standard specifications 1/81/4 1/43/8 1/43/81/2 , AFD20-A 40 87.6 9.8 20 45 AFD30-A 53 115.1 14 26.7 30 50 AFD40-A 70 147.1 18 35.5 38.4 75 AFD40-06-A 75 149.1 20 35.5 38.4 75 3/4 Model Bracket mount dimensions AFD20-A 30 27 22 5.4 8.4 40 2.3 28 AFD30-A 41 35 23 6.5 13 53 2.3 30 AFD40-A 50 52 26 8.5 12.5 70 2.3
V L4=50+T+X 50 SMC H H L L O O S S U U C C P P K K 8 U 57 (at knob locked) DIN rail part no.
The EX245 will send a diagnostic alarm if the change of state between the two inputs does not occur within the specified time. 40 No.EX##-OMY0004 Start inhibit after discrepancy The parameter specifies behaviour of an input bit after detecting a discrepancy between input ch1 and ch2. When set to Disable, the input bit will still change after a discrepancy is detected.
40 60 80 100 120 140 160 180 200 220 240 260 100 m Straight 2 m 2S Temperature C Length Applicable to inch size only Note 4) Note 4) Eluting fluorine ion amount (g/g) Eluting metal ion amount (ng/cm2) Symbol 16 33 Type Length Type Fluorine ion Type Al Fe Ni Na Ca 50 Ft. (16 m) Roll 100 Ft. (33 m) Eluting amount 0.1 or less Eluting amount 4.5 0.3 0.2 7.1 1.3 Please refer to the Series and
Prassuro 1s0 PSIG (9.9 Kgflcm ) Prool Pr333ure 225 PSIG (15 Kgr cm ) Amblnl Temp. 40 120"F (5 50"C) Responsg Tlme 30 ms Max. 50 ms Max. 30 ms Max. 50 ms Max, Hysteresls 3% F.S. Repeatablllty 3/. Sensitivity o.5/.
40 60 80 100 120 140 160 180 200 220 240 260 100 m Straight 2 m 2S Temperature C Length Applicable to inch size only Note 4) Note 4) Eluting fluorine ion amount (g/g) Eluting metal ion amount (ng/cm2) Symbol 16 33 Type Length Fluorine ion Al Fe Ni Na Ca Type Type 50 Ft. (16 m) Roll 100 Ft. (33 m) Eluting amount 0.1 or less Eluting amount 4.5 0.3 0.2 7.1 1.3 Please refer to the Series and
20 10 0 1 5 10 50 100 100 90 80 100 90 80 70 60 50 40 30 20 10 0 100 200 300 400 500 100 200 300 400 500 100 200 300 400 500 Elimination ratio (%) Elimination ratio (%) Elimination ratio (%) 75 70 60 50 40 30 20 10 0 1 5 10 50 30 100 1 5 10 50 100 Flow-back count Flow-back count Flow-back count Explanation of graph Explanation of graph Example: Elimination ratio and concentration after using
/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz 3 Note 2) 2 1 Orifice dia.
AV Tightening Torque when Piping Connection thread Applicable torque (Nm) M5 x 0.8 1.5 to 2 1/6 rotation 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 40 to 42 48 to 50 48 to 50 AU Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/4 Rc 1 Rc 1 1/4 Rc 1 1/2 Rc 2 AF Model Connection R AN120 AN110 AN200 AN300 AN400 AN500 AN600 AN700 AN800 AN900 Effective area (mm2) AR M5 x 0.8 1 8 1 4 3 8 1 2 3 4 5 35
2 kg 49 68 95 110 123.5m) 1 2ANR[2065%] 3[3275%] 4 5 6R 30mA 7IPCC4 AR4 R410A GWP2090 8L V1.6MPa IDF60/70/80/90 Series 7-1 IDX-OM-W093 oC 530 35 40 45 50 55 60 65 IDF60/IDF70 1.26 1.00 0.78 0.64 0.54 0.42 0.35 0.27 IDF80/IDF90 1.30 1.29 1.00 0.81 0.63 0.55 0.47 0.39 MPa 0.2 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0.3 1.6 IDF60/IDF70 0.70 0.74 0.87 0.92 1.00 1.02 1.05 1.05 IDF80/IDF90 0.64 0.75
No.PS-OMM0002CN-F / / ZSE80(F) ISE80(H) 2 9 10 11 14 14 16 17 19 19 21 21 21 F0 23 F1 OUT1 24 F2 OUT2 27 F3 27 F4 / 28 F5 30 F7 31 F8 32 F9 34 F10 35 F98 36 F99 38 39 42 42 43 50 50 52 -1No.PS-OMM0002CN-F (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems.