SMC Corporation of America
Elite Part Number Search
Search Results "LEJS63S3A-400-S2"

Movement Speed Position Acceleration Deceleration Force Value Area 1 Area 2 In pos force speed force mode mm/s mm mm/s2 mm/s2 mm mm mm mm/s 0 1 Absolute 100 50.00 1000 1000 0 0 0 100 0 0 0.1 2 Relative 50 10.00 1000 1000 0 0 0 100 0 0 0.1 (E.g.) Flow chart Controller (1) Select/input Step No.1.

Mount the switch in a location where there is no vibration greater than 98 m/s2, or no impact greater than 490 m/s2. With a switch with orifice, the adjusted flow rate value could be affected by vibration. 3. Do not use in an area where surges are generated.

CDRBU2W10, 15-S CDRBU2W20, 30-S CRB2 CRBU2 CRB1 2 x S2 2 x S1 2 x S1 MSU 2 x S2 CRJ Rotary actuator CRA1 CRQ2 2 x S1 2 x S1 2 x S1 2 x S1 Rotary actuator MSQ (34.5: Connector type) MSZ A port B port CRQ2X MSQX 2 x R A port B port 2 x R MRQ 1 Auto switch Auto switch 2 5 20.5 (26.5: Connector type) 1.

Kit/Electrical entry/Cable length F P Kit (Dsub connector) Kit (Flat cable connector) Connector location Top (vertical) Side (horizontal) Connector location Top (vertical) Side (horizontal) P .1.10-40 P .1.10-36 Without cable Without cable S0 S1 S2 S3 S0 S1 S2 S3 U0 U1 U2 U3 U0 U1 U2 U3 stations Max.16 (2) Max.16 (2) F kit P kit P kit F kit With cable (1.5m) With cable (3m) With cable (5m

P1 LED lever meter Sensor S1 S3 Red is on: Output OFF Green is on: Output ON S4 S2 + P2 Red 1 Gap too big S1, S2: Fixed orifice S3: Variable orifice (Set via adjustment knob) S4: Detection nozzle Red 2 Green 1 BEST POSITION The bridge circuit is constructed as shown in the diagram. Position the work piece in front of the nozzle (S4).

Dimensions 4-3.2 circuit board mounting hole Circuit board type DC24V MADE IN JAPAN + PCW-EC16Z00 4 4 YMX-F4 42 0 1 2 3 4 5 6 7 8 9 A B C D E F 1 + *S2 S1 2 3 4 4 4 (28.5) 3 130 With cover (DIN rail mount compatible) With cover (DIN rail mount compatible) 16.7 DC24V MADE IN JAPAN + PCW-EC16Z01 28.3 YMX-F4 45 0 1 2 3 4 5 6 7 8 9 A B C D E F 1 + *S2 S1 4.1 2 3 4 (48.5) 5.1 (50) 133 10.5 10.5

Without release valve Without pressure sensor/switch for vacuum With pressure sensor 30 m/s2 Vibration resistance Note 1) Pilot operated dual 2 port Pilot operated 2 port Valve configuration 20 m/s2 0.3 to 0.6 MPa Operating pressure range With switch for vacuum Poppet seal Valve construction Without pressure sensor/switch for vacuum With pressure sensor 150 m/s2 Impact resistance Note 2)

to the Speed (Unit: mm/s2) The setting to define the pushing operation or the positioning operation.

Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

without control unit and bracket mounted, Others 30 m/s2, whichever is smaller for 2 hours in X, Y, Z direction each (De-energized) Vibration resistance Without control unit and bracket mounted: 980 m/s2, Others: 150 m/s2 in X, Y and Z direction, 3 times each (De-energized) Nil: Rc 1/8, N type: NPT 1/8, F type: G 1/8 4-core, oil resistant, cable (0.64 mm2) with M12, 4-pin pre-wired connector

Note 3) For detailed specifications other than the above, refer to the separate technical operation manual that can be downloaded from SMCs website (http://www.smcworld.com/). 10 to 150 Hz with a 0.035 mm amplitude or 4.9 m/s2 in each X, Y, Z direction for 2 hrs (De-energized) 147 m/s2 in each X, Y, Z direction, 3 times (De-energized) Standard CE marking, UL (CSA) Communication connector

External terminals (including the FE terminal) and enclosure screws Insulation resistance 10 M or more 500 VDC External terminals (including the FE terminal) and enclosure screws EN61131-2 compliant 5f<8.4 Hz 3.5 mm Vibration resistance 8.4f<150 Hz 9.8 m/s2 Impact resistance EN61131-2 compliant, 147 m/s2, 11 ms Mounting Through hole for M4 screw (2 pcs.)

ZB-OM00201-B Specifications General Specifications Ambient -5 to 50oC (No condensation) temperature range Fluid Air, inert gas Vibration 30m/s2 (Without pressures sensor/vacuum pressure switch, With pressure sensor) resistance Note 1) 20m/s2 (With switch) Impact 150m/s2 (Without pressures sensor/vacuum pressure switch, With pressure sensor) resistance Note 2) 100m/s2 (With switch) Note 1)

Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

Mount switches in locations where there is no vibration greater than 98 m/s2, or no impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.

Do not drop, bump, or apply excessive impact (PSE540: 980 m/s2, PSE560: 500 m/s2) while handling. Although the body of the sensor may not be damaged, the inside of the sensor could be damaged and lead to malfunction. 2. The tensile strength of the cord is 50 N. Applying a greater pulling force to it can cause malfunction.

Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.