Real-time switch output Hysteresis mode Unit switching ON YES OFF P-1 P-2 For Air Instantaneous flow rate Display Instantaneous flow rate Accumulated flow "P" Window comparator mode H : Hysteresis L/min L CFM x 10-2, CFM x 10-1 ft3 x 10-1 H H ON CFM = ft3/min NO OFF P-1 P-2 High Flow Rate Type (For Air) Instantaneous flow rate OUT1 Output mode Display Instantaneous flow rate Accumulated

, PLC 100 V, 200 V Yes Yes 12 V PLC Terminal conduit 2-wire 24 V 100 V, 200 V DIN terminal Grommet Relay, PLC Diagnostic indication (2-color indication) 3-wire (NPN) IC circuit 24 V 5 V, 12 V 3-wire (PNP) Grommet 100 V, 200 V 12 V 5 V, 12 V 12 V 2-wire IC circuit 3-wire (NPN) Terminal conduit 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type), Bracket: A4 (Bracket D for M12 Connector Type), Operation Manual: K (Operation Manual, Calibration Certificate)

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: w/o Operation Manual, w/o Calibration Certificate

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: w/o Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø4 One-touch Fitting, Elbow Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: w/o Operation Manual, Calibration Certificate