DCDC 4 2 RA 11 27 11 (c) AERSBAN-SET SD (AB) 40 [mm] 2-5 2-5 17.5 30 L 10 L B0.3 7 A C 11 3 6 240.3 -0.2 35 0 24 0 6 22 M4 ()M4 35 .
[Unit: mm] Strip the cable sheath of the clamped area. cutter Cable Cable clamp Earth plate (A, B) cable 40 External conductor Clamp section diagram Dimensions [Unit: mm] [Unit: mm] Earth plate Clamp section diagram 25 hole 17.5 installation hole 30 24 L or less 10 B 0.3 C A 6 -0.2 0 35 11 3 24 + 0.3 0 7 6 22 (Note) M4 screw 35 Note. Screw hole for grounding.
(c) AERSBAN-_SET SD [:mm] (A B) 40 [mm] [mm] 2-5 17.5 30 B0.3 10 L A 35 C +0.3 6 -0.2 24 0 24 0 3 7 6 22 ()M4 3 5 11 . A B C L AERSBAN-DSET 100 86 30 2 A 70 AERSBAN-ESET 70 56 B1 B 45 11 22 11.
CCVS02-G-S 45 80 86 35 25 1 36 17.5 88.2 72 148.5 103.9 45 1/2 101 CCVS1-G-S 45 80 86 35 18 35 25 2 36 17.5 72 98 148.5 57 1/2 121.8 101 M5 x 0.8 5.4 to 7.5 CCVS2-G-S 45 80 86 35 18 35 25 1 36 17.5 88.2 72 98 148.5 57 1/2 103.9 101 CCVS3-G-S 45 80 86 35 18 35 25 1 36 17.5 88.2 72 98 148.5 57 1/2 103.9 101 CCVS0-S 45 80 86 35 25 36 17.5 88.2 72 98 57 1/2 CCVL02-G-S 66 107
Nil Side ported B Bottom ported 493 VQ5000 Series Dimensions: Plug-in Type Conduit terminal 2-position single: VQ510 0 1 194.8 2 2 195 105.8 59.5 73 121.8 73 59.5 27.5 27.5 4(A) port 17.5 13.5 2(B) port 10.0 M5 x 0.8 Ground screw 3/8" 5(R1), 3(R2) port Indicator light 4 2 SMC 5 1 3 16 16 13 A 53 53 66 40 66 B A VQ5000 4 2 14 5 1 3 12 17.5 13.5 35 53 2 x 6.5 Mounting hole Manual override 35
B 35 40.5 QA 6 8 QB 13 16 QV 33 38.5 A 47 58 Bore size (mm) 40 50 J D-X 20Data 10-8-19 20 20 Series RSG Rod End Configuration: Roller Type Basic style: Flange mounting These 2 figures show the piston rod extended.
5.16.1 Accumulated operating time reset function . 5-35 5.16.2 How to operate accumulated operating time reset function . 5-35 5.17 Warming Up Function . 5-39 5.17.1 Warming up function. 5-39 5.17.2 Setting/checking of warming up function . 5-40 5.18 Anti-Snow Coverage Function . 5-42 5.18.1 Anti-snow coverage function . 5-42 5.18.2 Setting/checking of anti-snow coverage function . 5-43
(C) IDF 1D 30 35 40 50 25 IDF 2D to 240D 30 35 40 45 50 Outlet air press. dew point (C) Ambient temp.
Valve exhaust noise dampening: 35 dB or more. Collection rate of drainage and oil mist: 99.9% or more. Piping work is reduced.
Vacuum pressure Suction flow rate 13-5-5 Series ZH Box Type (Built-in silencer): ZHB -S L One-touch connection Applicable tubing diameter B Model A 60 6 22 16 12.8 28 5 47 60 6 22 16 12.8 28 5 47 60 6 22 16 12.8 28 5 47 60 6 22 16 12.8 28 5 47 63 6 23 18 12.8 29 5 50 63 6 23 18 12.8 29 5 50 78 8 27.5 23 13.7 35 7 61 78 8 27.5 23 13.7 35 7 61 B C D E F G H ZH05BS-06-06 ZH05BL-06-06 ZH07BS-
Refer to the dimensions on page 27 for the mounting dimensions. (35) (25) 5.5 1.25 L Dimension [mm] No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L 110.5 135.5 160.5 185.5 210.5 235.5 260.5 23 35.5 48 60.5 73 85.5 98 123 148 173 198 223 248 No. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 L 285.5 310.5 335.5 360.5 385.5 410.5 435.5 460.5 485.5 510.5 273 298 323 348
EN EU CH H6 ER (Max.) 32 ES5032 11 10 6.6 38 51 8.5 21 18 31 14 10.5 32 10 15 40 ES5040 11 12 6.6 41 54 8.5 24 22 35 16 12 36 10 18 50 ES5050 15 16 9 50 65 10.5 33 30 45 21 15 45 12 20 63 ES5063 15 16 9 52 67 10.5 37 35 50 21 15 50 12 23 80 ES5080 18 20 11 66 86 11.5 47 40 60 25 18 63 14 27 100 ES5100 18 20 11 76 96 12.5 55 50 70 25 18 71 15 30 139 Accessories CP96 Series Dimensions: Piston
Burst pressure Precautions Min. bending radius (mm) 10 15 20 27 35 10 15 23 27 35 Operating temperature Be sure to read before handling.
30 23 18 15 12 11 10 MGPL 16 38 31 27 23 21 37 32 27 24 22 20 MGPM 16 12 54 40 32 54 47 35 28 23 20 17 15 MGPL CL 42 49 36 32 43 38 29 35 87 75 66 59 54 49 MGPM 20 35 58 30 26 48 101 23 90 70 58 62 54 48 43 MGPL MLGC 55 69 48 43 60 54 38 49 116 100 88 79 71 MGPM 65 25 45 82 38 33 68 132 29 118 93 77 80 70 62 MGPL 55 CNA F 91 203 80 71 64 164 182 159 142 127 MGPM 116 106 32 137 191 121 108
KQ2P-04 KQ2P-06 KQ2P-08 4 16 32 6 6 18 35 8 8 20.5 39 10 A A A B A B A FREE LOCK 1-3-11 Series SZ3000 Manifold Option DIN rail dimensions/Weight D-sub connector (25 pins)/Cable assembly AXT100-DS25015 030 050 VZ1000-11-1Refer to the L dimension tables Enter a number from the DIN rail dimension table below.
With n stations, it attaches to the first switch and the nth switch. 3 105 36 4 140 71 5 175 106 6 210 141 2 70 Station L1 L2 PSE IS ISG ZSM Body Manifold With DIN rail L1 Lead wire (5 m) 35 (18) Deviation level indicator light Deviation level indicator light SUP port 25 25 Rc 1/8 90 SUP DIN rail center 4.5 90 35 4.5 35 40 30 (4.5) 35 70 Setting dial Gauge Gauge L2 L3 12 EXH port Station
AR 35 Note) P 1 1 2 1 0.02 to 0.2MPa Note) Pressure display unit: MPa, psi 4 1 G46-P2-02-X30 25 35 0.05 to 0.83MPa Note) 2 Pressure gauges are shipped with regulator, (but not assembled).
With n pcs. 35 100 110 D-A3 D-G39 D-K39 110 + 30(n 2) (n = 2, 4, 6, 8) 110 + 100(n 2) (n = 2, 4, 6, 8) 35 + 30(n 2) Different surfaces 100 + 100(n 2) Same surface 15 110 With 1 pc. Different surfaces Same surface 35 55 110 110 + 30(n 2) (n = 2, 4, 6, 8) 110 + 50(n 2) (n = 2, 4, 6, 8) 35 + 30(n 2) Different surfaces D-A44 55 + 55(n 2) Same surface 15 110 With 1 pc.
There may be the case it will vary substantially depending on an ambient environment. 4.5 5 6 6.5 6.5 7 4 35 40 40 45 45 45 45 50 D-G5NBL Mounting Bracket Part No.