1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 77 ?5F)Lights up when output is turned ON.
OUT() DC(-) DC(+) PSE57-02-28 420 mA N.C. 500 (24 V ) 100 (12 V ) OUT() DC(-) -11No.PS-OMT0005CN-A (A/D ) () 20 2030 -12No.PS-OMT0005CN-A PSE575 PSE576 PSE577 02 MPa 05 MPa 010 MPa 5MPa 12.5MPa 30MPa 5%F.S.(25 ) PSE57-02 PSE57-02-28 DC1224 V1010% 10 mA 420 mA 15 V 1 k 500 (24 V ) 100 (12 V ) (25 ) 2.5F.S. 0.5F.S. 0.5F.S.(25 ) IP65 AC500V 1 100M(DC500 V) -1060 -2070 ()
PFMV V PFMV V PFMV V Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about panel cut-out and mounting hole dimensions. Safety Instructions 3. Press the button to complete the setting of OUT1. [n_2] or [P_2] will be displayed. Set as above.
and D-A93(V): Oil proof vinyl cabtire cord 2.7 0.18mm22-core (brown, blue) 0.5m D-A96(V): Oil proof vinyl cabtire cord 2.7 0.15mm23-core (brown, black, blue) 0.5m Isolation resistance 50M or more at DC500VM (between lead wire and case) Withstand voltage AC1500V for 1 minute (between lead wire and case) Operating time 1.2ms Ambient temperature -10 to 60C Shock resistance 300m/s2
1/2 Type M 2.7 3.2 3.3 2.7 3.2 3.3 Mass kg Type V 3.1 3.7 3.8 3.1 3.7 3.8 * Note 1.
The change of vacuum pressure is explained in sequence as follows. 1 When the vacuum port (V) is closed, the suction flow will be 0 and the vacuum pressure will reach its maximum (Pmax). 2 When the vacuum port (V) is opened gradually, air will flow.
In the case of V arrangements, the side having the largest branches is considered to be the vertical side (at 12 oclock); the other side is either to the right or left of vertical as viewed from the threaded end of the fitting.
V 2-wire Refer to page 12-13-25 for solid state switch with pre-wire connector.
V 2-wire Refer to page 12-13-25 for solid state switch with pre-wire connector.
Load voltage Electrical entry Lead wire length (m) Auto switch model Electrical entry Indicator light Wiring (Output) Pre-wire connector Special function Applicable load In-line 0.5 (Nil) 3 (L) 5 (Z) DC AC Type Perpendicular 3-wire (NPN) 3-wire (PNP) Y59A Y69A IC circuit 5 V 12 V Y7P Y7PV Solid state switch 12 V Y59B Y69B 2-wire Relay, PLC Grommet Yes 24 V 3-wire (NPN) 3-wire (PNP) Y7NW
24 V DC 100 V 110 V AC 200 V 220 V AC 50/60 Hz 50/60 Hz 4/2 5/3 (A/B R1/R2) 3 position Closed center Double Single Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal VQ130 0.73 0.84 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258
Max. voltage (with no load): 30 Vrms (42.4 V peak) or less Max. current: 8 A or less (including shorts), and When controlled by a circuit protector (fuse) with the following ratings: No-load voltage (V peak) Max. current rating 0 to 20 [V] 5.0 100 Over 20 [V] and up to 30 [V] Peak voltage value (2) A circuit (class 2 circuit) with maximum 30 Vrms (42.4 V peak) or less, and a power supply
(Element life check) Max. contact capacity: 10 VA AC, 10 W DC Rated contact voltage (max. operating current): 125 V AC (0.08 A), 30 V DC (0.33 A) Max. contact capacity: 10 W DC Rated contact voltage (max. operating current): 30 V DC (0.33 A) Pressure drop 0.1 MPa Symbol V: Degreasing wash, white vaseline Reed switch Reed switch Body/housing is degreasing washed.
(NPN) 3-wire (PNP) 2-wire IC circuit 5 V, 12 V 12 V Diagnostic indication (2-color indication) Auto switches marked with are produced upon receipt of order.
24 V or less 100 V 0 0.1 0.2 0.3 0.4 Pressure setting scale Maximum operating current and range 40 mA 50 mA 20 mA Impact resistance 30 G 14-4-21 4 Series ARM11A Flow Characteristics Condition: Inlet pressure 0.7MPa Condition: Inlet pressure 0.5MPa ARM11AA1-307 (One-touch fittings: IN 6, OUT 4) ARM11AA1-307-1 (One-touch fittings: IN 6, OUT 4) 0.35 0.6 0.7 0.30 Outlet pressure MPa Outlet pressure
or less (With load current of 80 mA) (PF2D300, PF2W300, PF2W330) Maximum applied voltage: 30 V 2 outputs Environmental resistance Note 4) Output specifications Switch output PNP open collector Maximum load current: 80 mA Internal voltage drop: 1.5 V or less (With load current of 80 mA) (PF2D301, PF2W301, PF2W331) 2 outputs NPN open collector or PNP open collector (Same as switch output) Accumulated
Wire core color For PSE200 (ZS-26-E) Brown (DC (+)) Black (OUT: 1 to 5 V) Blue (DC (-)) Not connected Connector no. 1 2 3 4 PF2 For PSE300 (ZS-28-C) Brown (DC (+)) Not connected Blue (DC (-)) Black (OUT: 1 to 5 V) IF Controller Data Handling Confirm that the numbers on the connector match the colors of the wires and that the wires are inserted to the bottom.
V J Rod Cross Sectioo Rod Cover Head Cover Head Cover uNrT rNcH (MM) 4srrc SERIES NCJ2K Non-rotating Piston Rod Type: Double Acting/Singte Rod I Rod Side Flange Type (F) nc.,zxrl6G!
CEP1 Adjustment dial Option CE1 With cancel cap With lever detection switch With lock mechanism V m/min CE2 Work W Work W Work W ON OFF ML2B Work W Work W Cancel cap Drag C J G5-S Lever detection switch CV Bracket MVGQ The cancel cap holds the lever horizontally allowing a pallet to pass.
Core wire colors M12 48 1 1 2 3 4 5 2 : DRAIN 6 5 Red: V+ Black: V 16 White: CAN H Blue: CAN L M12 4 3 14.9 Socket connector pin arrangement Connections Terminal no.