SMC Corporation of America
Elite Part Number Search
Search Results "CDLSD140TN-200-A93-DA93"

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 to 50 Indoor Three phases 200 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Single phase 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Power source 90 130 0.4 0.45 1.44 1.4 50 60

Fluid name Applicable element Air (Dry) Lubricating oil (20 mm2/s) Industrial water Fragrances (1 mm2/s) Nominal filtration accuracy (m) Cotton Polypropylene Paper Micromesh Applicable filter model 0.5 Note 1) 10 Note 1) 1 5 10 20 10 5 FGDCA 110 550 11 21 23 26 22 29 03 FGDEA 110 750 12 27 30 36 28 42 04 FGDTA 110 1000 13 32 36 46 32 57 06 FGDFA FGDCB 200 600 17 25 26 28 26 30 03 FGDEB 200

TH0604N Color KQB2 Translucent 250 m reel 500 m reel X64 KS KX Reinforced corrugated cardboard specification: Longer length reel/-X64 KM Dimensions KF Dimensions M Model D1 D2 D3 W Weight (kg) H/DL L/LL TH0604N-250-X64 TH0604N-500-X64 200 200 475 475 52 52 120 220 9.4 18.5 D1 KC KK D2 D3 W KK130 DM KDM KB KR KA KQG2 KG KFG2 MS KKA KP LQ MQR T T IDK 507 FEP Tubing (Fluoropolymer) Inch Size

mm 200 mm AM30-D AFF30-D AMD30-D AMK30-D 1 Modular Connection Type Compressed Air Preparation Filter AFF/AM/AMD/AMK Series Easier replacement of the element Size 50/60 The stopper function prevents the bowl from falling.

Rated Rated Sensitivity supply voltage x size voltage current of leak [V] [A] current [mA] 3 cores x 10 30 HRS030--20 1-phase 14AWG (3 cores x 2.0mm2) 200, 200-230V AC 230 HRS030--20-T (50/60Hz) 15 30 (including (High pump head [Optional]) ground) HRS Series 3.3 Installation 3-9 HRX-OM-R016 Chapter 3 Transport and Setting Up 3.3.3 Preparation and wiring of power supply cable The electrical

Max. 2s 2s 1s 1s Min. 0.5s 0.5s 0.2s 0.2s 0.1s 0.1s 0.05s 0.05s 0.02s 0.02s 0.01s 0.01s 6000 100 125 200 300 400 500 700 1000 1500 2000 30004000 10 100 125 200 300 400 500 600700 1000 1500 2000 3000 4000 600 5000 7000 Current (% for breaker capacity) Current (% for breaker capacity) For HRS100-A/W-20-B For HRS150-A/W-20-B HRS100-A/W-40, HRS150-A/W-40 4h 2h 1h 30min 20min 14min 10min 6min

Symbol Port size Max. flow capacity L/min (ANR) 3A 4 30 4B 6 65 5C 8 130 7D 10 200 Male thread type One-touch fitting type Symbol Applicable tubing O.D.

VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz JIS Symbol Internal pilot (50A) 2 VFN 4 5 6 24 VDC 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option How to Order Pilot Valve Assembly External pilot 00 VT3113 G 1 Coil rated voltage Electrical entry 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz G Grommet Conduit terminal DIN terminal TL D T Note) N.O.

For sub-plate, manifold type 40, 41, 42 P, E port R port Port size 3:Common exhaust type for main and pilot valve Nil: Without sub-plate D: Push-turn locking slotted type P, E port R port Electrical entry (With gasket and screws) 24, 12, 6, 5, 3 VDC 100,110, 200, 220 VAC Grommet L plug connector M plug connector 24,12 VDC 100,110, 200, 220 VAC DIN terminal 24, 12, 6, 5, 3 VDC M8 connector

Q P R O D U C T S Q Q Q Q Q Q 3 Q Q 3 Port 100/200/300 Series VQZ Base Mounted & Body Ported High speed and Long life. Response time Life VQZ100 10ms VQZ200 12ms 200 million cycles VQZ300 15ms Dispersion accuracy 2ms * Life: Metal seal type * Response time: Metal seal, single solenoid with light and surge voltage supressor.

Detection nozzle: 1.5 Piping: F type: 4 x 2.5 tube Test conditions G, H type: 6 x 4 tube Reference pressure: 150 kPa : Use within the rated pressure range (100 kPa to 200 kPa). It will be impossible to measure the gap when the operating pressure is less than 80 kPa or more than 220 kPa and the output will be OFF.

rate: 50% Stroke 300 mm 6 10 16 20 25 32 40 Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ3140-M5 Cylinder is in extending.

(L/min [ANR]) 300 150 SUP = 0.5 MPa SUP = 0.5 MPa SUP = 0.4 MPa 200 SUP = 0.4 MPa 100 SUP = 0.3 MPa SUP = 0.3 MPa SUP = 0.2 MPa SUP = 0.2 MPa 100 50 0 5 0 0 10 0 10 15 20 25 20 30 40 50 Discharge rate (L/min) Discharge rate (L/min) PAF3413 Air Consumption (2 Hz) PAF5413 Air Consumption (1 Hz) 200 Air consumption (L/min [ANR]) Air consumption (L/min [ANR]) 300 150 200 100 SUP = 0.5 MPa SUP

A parallel key is used instead of chamfer for size 40. +4 0 = Max. = 110 e g n a r End of rotation n +4 0 = Max. = 200 o i t e g a n a t r o n R o i End of rotation t a t o R (90) DChamfer (Start of rotation) Start of rotation is the position of the chamfer (key) when B port is pressurized.

S Without connection port (For manifold) 00 Electrical entry Rated voltage 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz CE-compliant G Grommet, Lead wire length 200 mm C Conduit D DIN terminal T Conduit terminal Terminal with indicator light TL DLDIN terminal with indicator light Note1) CE-compliant: Electorical entry

A parallel keyway is used instead of chamfer for size 40. +5 0 +5 0 +4 0 = Max. = 200 +4 0 = Max. = 110 End of rotation e g e n g a n r a r n n o o i t i a t a t End of rotation o t o R R Chamfer (Start of rotation) Chamfer (Start of rotation) (90) (45) A port B port A port B port Start of rotation is the position of the chamfer (keyway) when B port is pressurized.

Relay, PLC 100 V Reed switch Solid state switch PLC 100 V, 200 V Relay, PLC 12 V Yes Yes 24 V 2-wire Terminal conduit PLC 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) 5 V, 12 V 24 V IC circuit Grommet 100 V, 200 V 2-wire 12 V IC circuit 3-wire (NPN) 2-wire Terminal conduit 5 V, 12 V Relay, PLC 12 V 3-wire (NPN

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.30 0.35 0.6 0.7 Outlet pressure MPa Outlet pressure MPa 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0.00 0 50 100 150 200 0 50 100 150 200 250 300 Flow rate /min(ANR) Flow rate /min(ANR) Condition: Inlet pressure 0.7MPa Condition: Inlet pressure

Cutout window View A-A' Mounting Standard Stroke GK BP AG AB A AA AN B GD AH AI AJ AK AL AM AO AP BZ GC Bore size (mm) 20 25 32 40 Stroke range (mm) 92 3.5 9 9 75, 100, 125, 150, 200 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 94 73.5 13 11 54 75 32 28 134 150 108 140 M 8 135 110 4 9 9 104 86.5 16 15 62 88 37 29 160 176 125 165 M 8 160 75, 100, 125, 150, 200, 250, 300 110 4 9 9 104 86.5 16 15 62 88 37 30

Standard Strokes Symbol Rubber bumper Bore size [mm] Standard stroke [mm] 12 (10 x 2) 16 (12 x 2) 10, 20, 30, 50, 100 20 (16 x 2) 25 (20 x 2) 20, 30, 50, 100, 150 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) 25, 50, 100, 150, 200 Intermediate strokes are available as a special order. Refer to pages 10 and 11 for cylinders with auto switches.