spacer: None, Compatible Model: AC40-06-B, AC40B-06-B, AC40C-06-B, Piping connection port diameter: NPT 1/4
AS Series How to Order 2 2 0 01 06 W2 AS 1F Body size 2 1 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard 3 4 Metric size Applicable tubing O.D. Note) Elbow 06 08 10 12 6 8 10 12 Control type Meter-out Meter-in 0 1 Note) For applicable tubing O.D. selection, refer to the Model on page 603.
Note) Metric size Inch size Control type KE 0 1 Meter-out Meter-in 3.2 01 03 05 07 09 11 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 23 04 06 08 10 4 AS-FG 6 8 With One-touch fitting AS-FP 10 AS-FM AS-FM For low speed control Note) For applicable tubing O.D. selection, refer to the Model on page 716. Use 1/8" tube.
How to Order AS 2 2 0 1F G 01 06 W2D Flame resistant flat head screwdriver adjustable Body size 2 1/8, 1/4 standard 3 3/8 standard 4 1/2 standard Applicable tubing O.D.*1 Metric size 06 6 08 8 10 10 12 12 Elbow Control method 0 Meter-out 1 Meter-in *1 For selecting applicable tubing O.D., refer to the Model shown above.
Series VQZ base mount solenoid valves combine convenience with durability and performance in a more traditional mounting style. Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style.
Series VQZ base mount solenoid valves combine convenience with durability and performance in a more traditional mounting style.
Function: 3 (3 Position Closed Center), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: A (Non-locking Push Extended Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 06 (Sub-plate Plug-in Terminal
Function: 3 (3 Position Closed Center), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 06 (Sub-plate Plug-in
Function: 3 (3 Position Closed Center), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 06 (Sub-plate Plug-in
Actuation options include 5 port single solenoid, 5 port double solenoid, and dual 3/2 ported. Manifold variations for the SQ plug-in series include EX510 Gateway-type serial transmission system, D-sub connector, flat ribbon cable connector, PC wiring system compatible flat ribbon cable, terminal block box, or a lead wire kit.
Actuation options include 5 port single solenoid, 5 port double solenoid, and dual 3/2 ported. Manifold variations for the SQ plug-in series include EX510 Gateway-type serial transmission system, D-sub connector, flat ribbon cable connector, PC wiring system compatible flat ribbon cable, terminal block box, or a lead wire kit.
Fluid: 0 (Petroleum), Port Size Category: A (1/2, 3/4, 1), Std. T Dimension, mm: 4 (Port 1/2-1: 520, 1 1/4-2: 685, 2 1/2-3: 850), Filtration: 74μm, Port Size: 06 (3/4), Pressure Indicator: 1 (Differential Pressure Indicator), Connection: 3 (L-block Female Threaded Companion Flange)
Function: 3 (3 Position Closed Center), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 06 (Sub-plate Plug-in
Function: 3 (3 Position Closed Center), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: E (Grommet Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: B (Bottom Ported), Port Size: 06 (Sub-plate Plug-in Terminal 3/4, Non
Function: 3 (3 Position Closed Center), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: E (Grommet Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: B (Bottom Ported), Port Size: 06 (Sub-plate Plug-in Terminal 3/4, Non
: 06 (Sub-plate Plug-in Terminal 3/4, Non Plug-in Standard 3/4)
Function: 3 (3 Position Closed Center), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 06 (Sub-plate Plug-in
Terminal 3/4, Non Plug-in Standard 3/4)
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: A (Non-locking Push Extended Style), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: A (Out 1: NPN, Out 2: Flow Rate: NPN, Temp.: None,Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket