Bore size (mm) Stroke range (mm) OB P1 P2 Q RA RB S V W Y Z 32 40 50 63 9 M5 x 0.8 M5 x 0.8 2.5 10 7 12 43 43.5 59 38 5 to 100 9 M5 x 0.8 M5 x 0.8 2.5 10 7 12 43 43.5 67 46 5 to 100 11 Rc, G, NPT1/8 Rc, G, NPT1/8 3.5 14 8 17 54 63 83 58 10 to 100 14 Rc, G, NPT1/8 Rc, G, NPT1/8 3.5 18 10.5 17 54 63 97 69 10 to 100 6 Compact Cylinder with Solenoid Valve/Guide Rod Type Series CVQM Auto Switch
Enable Generates an error. 1 -10..10 V -5..5 V -20..20 mA 0..10 V 0..5 V 1..5 V 0..20 mA Set the analogue input device range per channel. 2 Analogue input range (Range) Selects the analogue input range. -10..10 V 4..20 mA Offset binary Offset binary. Sets analogue data type which is output to PLC per unit. 2s complement 2s complement.
Enable Generates an error. 1 Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 0..5 V 1..5 V 0..20 mA Sets the analogue input device range per channel. Analogue input range (Range) Selects the analogue input range. -10..10 V 2 4..20 mA Offset binary Offset binary. Sets analogue data type which is output to PLC per unit.
) 0.6 0.7 Critical pressure 0.65 [658] (158) 0.5 0.6 0.55 Sonic [656] (151) 0.5 0.4 0.45 [654] (143) 0.4 0.3 0.35 0.3 [650] (133) 0.2 0.25 0.2 [646] (120) 0.15 0.1 0.1 0.05 2 2 2 2 3 2 3 2 3 2 03 04 VX211 VX22 VX23 VX2 4 VX2 50 VX2 60-02 VX2 602 10 15 5 3 5 10 15 20 25 30 4.5 10 15 20 30 40 50 60 3 2 6 30 60 8 25 35 10 20 40 10 35 Flow rate Q kg/h Figures inside [ ] indicate the saturated
4 mA 4.16 mA 20 mA E F G Voltage output (0 to 10 V) 1 0 V 0.10 V 10 V 1: The analogue output current from the connected equipment should be 20 A or less when selecting 0 to 10 V.
Product number Suitable screws Tightening torque Thread depth PF3A703H Equivalent to M4 1.5 Nm 10 7 PF3A706H Equivalent to M5 3 Nm 10 8 PF3A712H Equivalent to M6 5.2 Nm 10 9 Prepared by the user.
L/min 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 24 VDC 10% Temperature characteristics (25C reference) 3% F .S. (15 to 35C) 5% F .S. (0 to 50C) 2% F .S.
(SI ) ON/OFF LED PLC ON/OFF 8 ST(M) () ST(M) SI 9 ST(M) OFF PWR () DC24 V10 10 PWR(V) () DC24 V+10/-5 (60 ) -39No.EX-OMN0029CN-D No. PLC SI PLC SI MS NS PLC (PLC MS NS ) 11 MS SI PLC SI MS NS/ DeviceNet V_SEL PLC SI PWR(V)LED DC24 V+10/-5 SI SI 12 SI EX600-SDN1A(PNP ) EX600-SDN2A(NPN ) SI SI -40No.EX-OMN0029CN-D No.
-15 -20 -30 -10 -15 -10 -15 -20 -30 -10 -15 -10 -15 -20 -30 -10 -15 1 9h9 M3 x 0.5 0.88 6 M3 x 0.5 0.88 6 3 6 M3 x 0.5 0.88 6 3 6 12h9 2 2 2 MHK 1.5 M4 x 0.7 2.1 8 M4 x 0.7 2.1 8 4 8 M4 x 0.7 2.1 8 4 8 14h9 M5 x 0.8 4.3 10 2 M5 x 0.8 4.3 10 5 10 M5 x 0.8 4.3 10 5 10 16h9 MHS 1 9h9 3 3 3 1.5 6 M3 x 0.5 0.88 M3 x 0.5 0.88 6 6 M3 x 0.5 0.88 6 6 3 3 12h9 MHC How to Locate Finger and Attachment
Applicable bore size (mm) SNJ-016SUS d A1 L L1 NDd9 MM B C H B C d H 0.030 0.060 0.030 0.060 10 10 10 14 7 3.3 8 16.2 4 8.1 3.2 15.2 21 M10 x 1.0 M4 x 0.7 M4 x 0.7 16 16 16 Y-J016SUS 17 8 NTJ-015SUS 5 11 19.6 4 9.2 4 SNKJ-016SUS 16.6 21 M12 x 1.0 M5 x 0.8 M5 x 0.8 NX R1 NDH10 U1 Part no. + 0.048 0 + 0.048 0 Y-J010SUS 3.3 3.2 8 10 Y-J016SUS 5 6.5 12 10 Rod End Cap CJ5 CG5 T-bracket Flat type
K 11 8 10 15 16 I 12 15 18 23 G 5.5 7.5 7.5 8 11 H 13 20 20.5 22 29 F 10 13 13 16 16 E 2 2 2 2 3 NN M10 x 1 M20 x 1.5 M26 x 1.5 M26 x 1.5 M32 x 2 D 16.6 21.6 26.4 33.6 41.6 MM M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 B 35 36 46 60 70 N 11 18 18.5 20 26 ZZ 103 132 137 156 182 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 Model 12-CY3B15 12-CY3B20
MPa) Operating direction Bore size (mm) 0.7 0.5 0.3 2015 11 6 IN 6 20 14 8 OUT Data 46 33 20 IN 10 55 39 24 OUT 121 86 52 IN 16 141 101 60 OUT Standard Stroke Bore size (mm) 6, 10, 16 Standard stroke (mm) 5, 10, 15, 20, 25, 30 Refer to Minimum Stroke for Auto Switch Mounting on page 8-3-10.
, 10, 16 Standard stroke (mm) 5, 10, 15, 20, 25, 30 Refer to Minimum Stroke for Auto Switch Mounting on page 8-3-10.
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time.
I1 = 0.03 x (0.02 + 0.01)/12 = 1.25 x 10-kgm I2 = 0.006 x (0.005 + 0.005)/12 + 0.006 x 0.007 = 0.32 x 10-kgm I = 1.25 x 10+ 0.32 x 10-6 I1 = m x (a + b)/12 I2 = m x (a + b)/12 + m x H I = I1 + I2 Inertial moment = 1.57 x 10-kgm Kinetic energy 6 1/2 x I x Allowable energy = 2 /t (: Terminal angular velocity) : Rotation angle (rad) 1/2 x 1.57 x 10-6 x (2 x ( /2)/0.2) Confirm that the load's
rotations Number of needle rotations Flow Valve: Series ASQ Meter-out Type (Inlet pressure: 0.3 MPa) ASQ430F ASQ530F ASQ630F 20 10 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Effective area mm2 Effective area mm2 Effective area mm2 400 6 200 15 300 4 500 10 5 200 100 2 5 100 10 5 0 10 5 0 10 5 0 Number of needle rotations Number of needle rotations Number of needle
Note 6) The flow rate unit is based on 0C and 101.3kPa. 2 For Air Digital Flow Switch Series PFA How to Order PFA5 Remote Type Sensor Unit 10 01 Wiring specification Flow rate range 3m lead wire with connector Without lead wire Nil N 1 to 10l/min 5 to 50l/min 10 to 100l/min 20 to 200l/min 50 to 500l/min Nil N F 10 50 11 21 51 Port size Thread type Size Applicable model Flow rate (l/min)
/4" x 11/10" 11/4" 31.75 11/10" 27.95 KQB2 O.D. 3.18 1/16" 1.58 0.086" 2.18 KS KX I.D.
AF AR 1) 2 3 1) () 2) 5 3) 4) 5 5) 6) 7 2-2. 1) 2) 3) 4) 5) 6) 7) 8) , 9) 10) 3 11) 12) () 13)/ 14) 8 1 P142. 2 3 4 5 6 7 2-3. 1 2) 3 4 5 9 1 P14[2. ] fR[N] [mm] 1. 2 3 10 4 51 1.
OO PP QQ RR SS TT UU VV Model Applicable gasket ML1C25 ML1C32 ML1C40 10 14 37 24 8 27 20 8 C11.2 16.5 18 46 30 12 32 22 8 C11.2 17 23.5 12.5 10 53 40 34 26 C14 A B C D E F G H I J K L M N O P Q R S T U V W Y Z Model ML1C25 ML1C32 ML1C40 274 260 137 140 88 108 87 85.5 60 74 97 100 42.5 26 34 206 28 24 5.6 9 5.5 M5 x 0.8 8.5 M6 x 1 9.5 11 M8 x 1.25 322 306 161 160 108 131 101 99.5 64 92 118