SMC Corporation of America
Elite Part Number Search
Search Results "11-CDJ2B10-15"

-2No.PF-OMO0007CN 1 1.5 3) 3) 1 1 () -3No.PF-OMO0007CN () () -4No.PF-OMO0007CN () * (100 ) :050 -5No.PF-OMO0007CN * (15 / ) FG 49 N () IN IN OUT OUT () IN () -6No.PF-OMO0007CN *) 6 33 2 () () 10 m DC(-)() () -7No.PF-OMO0007CN * ( ) () CE 050 -8No.PF-OMO0007CN * ON , 10 /23 3 OFF (19 ) * OUT -9No.PF-OMO0007CN (11 ) SI L/min L (11 ) 1/8 1/4 3/8 1/2 -10No.PF-OMO0007CN N

Specification Table Battery-less absolute encoder type (Step motor 24 VDC) Model EQFS25 EQFS32 EQFS40 Stroke[mm] Note1) 50 to 800 50 to 1000 150 to 1200 Horizontal 15 26 40 40 39.5 50 68 68 26 60 75 80 Work load [kg] Note.2) Vertical 2 6 12.5 15 4 10 16 20 4.5 4.5 25 40 to 400 20 to 1200 12 to 850 6 to 450 3 to 225 24 to 1100 16 to 750 8 to 450 4 to 125 30 to 1200 20 to 1000 10 to 500 5 to

Chamfered port size D (Recommended value) Rc, G NPT, NPTF Female thread size 1 8 1 4 3 8 1 2 10.5 to 11.8 14.1 to 15.8 17.4 to 19.4 21.7 to 25.1 10.2 to 11.8 13.6 to 15.8 17.1 to 19.4 21.4 to 25.1 15-1-11

4 13 14.2 18.5 8.7 19 7.5 B16 16 ZP16B 18 4 13 15.7 20 9.9 21 8.5 B20 20 ZP20B 22 4 15 19 23.5 12.4 25 10.5 B25 25 ZP25B 27 4 15 19.5 24 15.6 28 10.5 B32 32 ZP32B 34 4 15 24.5 29 18.9 37 14 B40 40 ZP40B 43 7 18 29.2 34 24.4 48 16 B50 50 ZP50B 53 7 18 33.2 38 32.4 57 19 Put in the symbol for material at the end of model no. 13-11-60

No.PF-OMG0010-H PRODUCT NAME Digital Flow Switch (Integrated display type) MODEL / Series / Product Number PF2A7##H Table of Contents Safety Instructions 2 Model Indication and How to Order 10 Summary of Product parts 11 Definition and terminology 12 Mounting and Installation 14 Installation 14 Piping 15 Wiring 16 Outline of setting 18 List of outputs 19 Function selection mode 20 F_0 Initialize

Doc.No.LFE*-OMZ0011 Product Name Electromagnetic Digital Flow Switch Integrated Display Type Model/ Series/ Product Number LFE#(Z) SMC Corporation Contents Safety Instructions 2 Model Indication and How to Order 11 Summary of Product Parts 14 Definition and Terminology 15 Mounting and Installation 17 Installation 19 Piping Method 20 Wiring 22 Setting the Detected Flow Rate 24 Function Setting

PAB*-OMY0018 PRODUCT NAME Process Pump MODEL / Series / Product Number PA5010 Contents Safety Instructions -P.2 to 3 Names and functions of parts P.4 Precautions P.5 to 9 Applicable Fluids P.10 Specifications P.11 Performance Curve P.12 to 13 Working Principle P.14 Maintenance Parts P.14 Piping and Operation P.15 Dimensions P.16 1 Safety Instructions These safety instructions are intended

Names and functions of parts.11 6. How to use.11 7. Specification and how to order. 13 8. Discharge capability . 15 9. Troubleshooting. 17 10. Outer dimensions . 19 2 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

Step 6 Tightening torque Nm Valves 3 Bolt Size Tightening Torque 3 1 X*C-25 1.5 Bolt 2 -40 2.5 1 -50 6 2 -63 6 4 4 -80 15 Bonnet assembly Body Assemble Body and Bonnet assembly by tightening the bolt in numerical order. Manually tighten bolts until O-ring is compressed.

With across flat of the guide bolt and tightening torque Width across flats Tightening torque (Nominal) (Nm) 10 1.5 0.27 16 2 0.54 20 2.5 0.95 25 3 2.25 0.2mm Gap gauge 0.2mm Surface plate 15 - 3-4.

20 2.5 0.95 25 3 2.25 0.2mm 0.2mm 14 - 3-4. 1025 (1)Assy (2) (3) (4) (5)Assy O Assy :GR-S-010(10g) O C 15 - 32,40 1C 2 3 4.Assy :GR-S-010(10g) C 32 3 40 4 32 2 40 2.5 Assy 16 - 3-5./ 1025 / / / / 1 12 13 2 10,16; 20;25; 14 20,25; 3 15 C 4 5 16 A 6 17 A 18 NO 7 19 NC 8 20 NBR 9 21 NBR 10 22 NBR 11 MHZ2-10 MHZ2-16 MHZ2-20 MHZ2-25 MHZ2-D MHZ2-C MHZ10-PS MHZ16-PS MHZ20

Note) Tighten within the tightening torque of 0.5 Nm 15%. Note: a) It is possible to wire even in the state of bare wire.

A side: Orange(Right) B side: Green(Left) Solenoid A Solenoid B Fixed DIN rail manifold Light/surge Voltage Suppressor Fixed "45", "45" DIN rail manifold to the setting side with screws, fix points as follows:2 to 5 stations: 2 points 6 to 10 stations : 3points 11 to 15 stations: 4 points 16 to 20 stations:5 points If fixed at lesser points than specified and use it, there could be a warp

CONTENTS SAFETY 2 General General 3 positions 5 positions Model Indication Method 5 Names and Functions of Individual Parts 6 Installation 9 3 positions Names and Functions of Controller 11 Example of Internal Circuit and Wiring 12 Setting 15 Operation Characteristics 20 Specifications 21 5 positions Names and Functions of Controller 23 Example of Internal Circuit and Wiring 24 Setting 27

Nominal10 2.6N ) Square embedded pressure gauge Applicable model Process Procedure Tools Check items Disassembly Remove the pressure gauge cover Rotate the pressure gauge cover 15 counterclockwise to pull out the pressure gauge cover.

Refer to Disassembly Drawing on page 11 for the part No. and the replacement procedure of the finger assembly and the body assembly. 15 - Construction/Parts list 2 MHF2-12D to 20D Components No. Description Material Note No.

Connecting port position Rotation angle 90 180 90 180 Front port Nil Side port E Applicable auto switches/ Refer to pages 7 through 11 for detailed auto switch specifications. Lead wire length (m) Auto switch part no.

15 16 20 24 9 11 13 100 150 180 65 85 120 130 180 220 60 76 110 102 136 184 4.5 4.5 6 239 291 403 22 32 42 128 167 235 122 160 220 3 122 160 220 10 10 10 AME550 AME650 AME850 AME450SAME, #4 AME550SAME, #5 AME650SAME, #6 AME850SAME, #7 4.6-26

Nominal10 ) Square embedded pressure gauge Applicable model Process Procedure Tools Check items Disassembly Remove the pressure gauge cover Rotate the pressure gauge cover 15 counterclockwise to pull out the pressure gauge cover.