Size: 205 (1/4 Standard), Control Range: FC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 06 (ø6), Push lock: A (Push-lock)
Size: 205 (1/4 Standard), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 06 (ø6), Push lock: A (Push-lock)
Size: 100 (M5 Standard), Control Range: FC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 06 (ø6), Push lock: A (Push-lock)
Body Size: 205 (1/8, Standard), Material: None, Applicable Tube O.D.: 06 (ø6)
Body Size: 100 (M5, Standard), Material: None, Applicable Tube O.D.: 06 (ø6)
Body Size: 200 (1/8, Standard), Material: None, Applicable Tube O.D.: 06 (ø6)
0 Exhaust portr Adjusting springe Upper diaphragmw Upper diaphragm chamberq SIG Lower diaphragmy Lower diaphragm chambert OUT IN1 Springo Valvei Pistonu IN2 171 A IL201/211/220 Series Construction 2 12 IL211 IL201 1 r r e t e !2 !2 u t u w w i !9 i !9 q q !7 !7 IN OUT IN1 OUT1 !0 !6 !3 o !3 q !8 !6 IN2 OUT2 !8 !7 !6 o IL220 !3 r e !2 w u y i !9 !5 @1 OUT IN1 !1 q @2 @0 IN2 !
Broken communication wire monitoring time. o r coming 60 sec. off AL34 Communication alarm is generated.
Broken wire exceeded. o r Broken wire 60 sec. AL19 Communication alarm is generated.
P V < 2 3 . 0 o C # 1 S V 3 0 . 0 o C M O D E R e m : 0 5.10.4 Circulating fluid set temperature The circulating fluid set temperature can be set by specifying the circulating fluid target temperature during Serial Remote mode.
4079 6.510 -9 Pam 3/sec -8 Pam 3/sec O :FKM 6.510 0.1MPa(abs) O :Kalrez R 4079 6.510 -7 Pam 3/sec -11 Pam 3/sec 6.510 5150() 560() s 0.61 *2 (D-A93) FKM AM350(), :A6063, :A5052P, :A5052, :SUS304 Rc1/8 () 0.2 kg 20 *1 *2, 4 - 2.
One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.
ARP3000-02 VY1 G ARP3000-02BG PPA How to Order JIS Symbol AL ARP 3000 BG R 02 Option Direct operated precision regulator Nil None Reverse flow R Thread type Accessory Nil N F Rc NPT G Nil None With bracket With pressure gauge B G Pressure gauges are shipped together with regulator, (but not assembled).
S S S Flow direction (1) Press the SET button once when the item to be changed is displayed on the display. The set value on the sub display (right) will start flashing. The output will not operate for 3 seconds after supplying power. The identification code of the product is displayed.
EVS1 01 3 M0 Valve Thread type Size Nil F T 01 02 Rc Size 01 G Size 02 NPTF Passage symbol Port size (A) 4 (B) 2 Size 02 Size 01 Piping specifications Symbol Nil A01 A02 FG Without sub-plate 1 (P) 5 (R1) 3 (R2) Side-ported 1/8 (A) 4 (B) 2 Side-ported 1/4 FHG Number of solenoids 1 (P) 5 (R1) 3 (R2) Sealing type S D (A) 4 (B) 2 Single Nil R Metal seal Double FJG Rubber seal 1 (P) 5 (R1
U C S O H L 1 Series IRV Dimensions IRV1000 IRV2000 53 55 41 30 50 SMC 35 P K U C SMC S O H L P K U C S O H L 40 34 8 x 6.5 15.4 x 5.4 Approx. 106 Approx. 50.6 18 Approx. 79 Atmosphere Atmosphere 45.5 13 SET VAC SET G SET G 30 SET VAC 43 Pad side Vacuum pump side Pad side Vacuum pump side Approx. 43 35 2-Rc 1/8 Connection port 2-Rc 1/8 Vacuum gauge port 2-Rc 1/4 Connection port Approx. 60
3 y u r !1 q t !2 !5 e !1 No.
OUT Standard specification Option Note) Water (Standard, up to 40C) Air (Standard, Dry) Turbine oil Vacuum (up to 1.3 x102 Pa) Carbon dioxide (CO2), Nitrogen gas (N2) Vacuum (up to 1.3 x101 Pa) (V, M) Non-leak (106 Pa m3/s or less) (V, M) IN N.O.
Insulation type Electrical entry Electrical option Class B G C D, T S Note) S L, Z 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) AC DC Note) Surge voltage suppressor is attached in the middle of a lead wire. 17-3-72 3 The VX series will be revised shortly.