Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Function: 2 (2 Position, Double), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 5 (24 VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)
Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: R (External Pilot), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Function: 1 (2 Position, Single), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: R (External Pilot), Voltage: 5 (24 VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Function: 4 (3 Position Exhaust Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: None, Port Size: 06 (3/4), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: DO (DIN Terminal w/o Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Body Size: 2 (M5 Basis), Thread: Metric Thread (M5)/R(PT), Port Size: M5X0.8, Applicable Tube OD: 06 (Ø6 mm), Sealant: None
"VALVE. 4/5 PORT SOLENOID VALVE. N lb. VFR.
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: E (Grommet Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Function: 4 (3 Position Exhaust Center), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)
Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)
Function: 4 (3 Position Exhaust Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: A (Non-locking Push Extended Style), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, LA, VXP/VXR/VXF BODY PORT 3/4 PT, 2.53913 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption (W) (Holding)Temperature rise (C)(Rated voltage) InrushHoldingVXP21AC5020 (32)114.545
Series VXP pilot operated 2 port solenoid valve for air, gas, steam, water and oil. Variations include energized open (N.C) and energized closed (N.O) valves, class B or class H coils, brass, BC6, or stainless steel body materials and NBR, FPM, EPR, PTFE seal materials., VALVE, MEDIA, VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, LA, VXP/VXR/VXF BODY PORT 3/4 PT, 3.04556 lb, ModelPower sourceFrequency
4/5 PORT SOLENOID VALVE. Valve, 5 Port Solenoid. 4.55 lb. I42.
4/5 PORT SOLENOID VALVE. Valve, 5 Port Solenoid. 1.777 lb. I42.