The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal
Peak/ Bottom value reset: A function to clear the peak value or bottom value when an external input signal is applied. 41 No.PF-OMU0002-D
Accumulated flow is selected: Refer to page 41 c. Accumulated pulse output is selected: Refer to page 42 d. Error output is selected: Refer to page 43 e. Output OFF is selected: Refer to page 43 Press the SET button to set. Return to function selection mode.
Width across flats of attachment 3/8 20.9 mm 1/2 23.9 mm 3/4 29.9 mm 1 41 mm 11/4 54 mm 11/2 54 mm After hand tightening the piping, apply a spanner of the correct size to the spanner flats on the product, and tighten it for 2 to 3 rotations. The tightening torque is shown in the table below.
Enabling/Disabling of AL27: CH2 electric conductivity increase alarm function (1) (2) (3) (4) Electric conductivity and alarm (AL27) setting HRL Series 5.4 Description of Screen 5-41 HRX-OM-W060 Chapter 5 Display and Setting of Various Functions Table 5.4-14 Settings of electric conductivity (AL27) No.
25 TEMP READY alarm (AL12) of TEMP READY function .5-27 Offset (TEMP OFFSET) function .5-30 Pump operation mode .5-32 Discharge pressure alarm (AL18/AL19/AL20) .5-34 Electric conductivity and alarm setting (AL28) .5-36 5.4.8 CH2 setting screen .5-37 Temperature rise/drop alarm (AL14/AL15) setting .5-38 TEMP READY alarm (AL16) and TEMP READY function .5-39 Offset (TEMP OFFSET) function .5-41
of TEMP READY function .5-26 Offset (TEMP OFFSET) function .5-29 Pump operation mode .5-32 Discharge pressure alarm (AL18/AL19/AL20) .5-33 Electric conductivity and alarm setting (AL28) .5-35 5.4.8 CH2 setting screen .5-36 Temperature rise/drop alarm (AL14/AL15) setting .5-37 TEMP READY alarm (AL16) and TEMP READY function .5-38 Offset (TEMP OFFSET) function .5-40 Pump operation mode .5-41
HRR Series 5.5 Advanced setting mode 5-41 HRX-OM-W002 Chapter 5 Display and Setting of Various Functions Contact input signal 2 delay timer 24. Press the [] key. Displays screen for setting the Contact input signal 2 detection delay timer for reading. Time for starting detection of the contact input signal 2 (sec) can be set. Setting range: 0 to 300sec. (Initial value: 0sec.)
55 41 84 20 15 XYD-50 178 128 79 2 53 75 52 95 20 17.5 XYD-63 209 163 100 3 61 87 95 70 121 20 19.5 XYD-80 268 193 117 3 80 114 110 83 144 20 26.5 10 XL-OMP0003-A 7.
Table 7 Auto Switch Mounting Height Auto switch model D-A9-900 D-M9V-900 D-M9-900 D-M9WV-900 D-M9W-900 Bore size(mm) Hs Ht Hs Ht 40 30 30 34 30 50 34 34 38 34 63 41 41 44 41 80 49.5 49 52.5 49 100 56.5 56 61 56 14 Table 8 Minimum Stroke for Auto Switch Mounting n:Number of auto switches(mm) brackets other Center trunnion Number of Auto switch model than autoswitches 40 50 63 80 100 center
Description Material Note 40 Auto switch 41 Magnet 42 Switch spacer Resin 22 - Basic circuit for using rotary actuator Circuit configuration The basic circuit for operating the rotary actuator using an air filter, regulator, solenoid valve, and speed controller is shown in Fig. (4).
The tool number can be changed. 41 - 5. Manual Operation tab (1) Manual operation The manual operation of the air gripper can be checked. By tapping the OPEN or CLOSE button, it is possible to perform an opening or closing action of the gripper. (2) Monitor sensor signal It is possible to confirm whether the Open position or Close position auto switch reacts. 5-5. Air supply Warning 1.
(It should not be changed) Unit name Fixed value 41 No.JXC-OMY0002-A Parameter name Range Description Activation W-AREA1 W-AREA2 ORG Correct [Link Offset] Fixed value This is the fixed value for this controller. It should not be changed. Sensor type Option 1 Undefined parameter No.11 Undefined parameter No.12 *1) The range varies depending on the electric actuator.
(LEC) . 41 13.1(LEC) . 41 13.2. 42 14./ . 43 15./ . 44 15.1 . 44 15.2 . 45 15.3 . 46 15.4 . 47 15.5 . 48 15.6 . 48 16. . 49 2 - 16.1/ . 49 16.2 . 49 16.3 . 51 16.4 . 51 16.5 . 52 16.6 . 52 16.7 . 52 3 - LEC-G Series/ 1) (ISO/IEC)(JIS) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety
Bending performance: According to the drawing shown below, life span about 4 million cycle can be achieved. 200mm Reciprocating with R25 bending speed 100times/min. 41
Please refer to the manual of the electric actuator for more details. 41 - 7.2 Basic parameter The "Basic parameter" is the data to define the operating conditions of the controller, conditions of the electric actuator, etc. Caution Writing of the parameter should be performed while the electric actuator is stopped.
51.5 49.5 57 80 40 43 71.5 45 74 41 70 49.5 84 48 78.5 61 84.5 100 50 53 83 55 85.5 51 81.5 60 95 58 90 71 96.5 11-4.
to 700 200 200 701 to 800 73 81 89 89 101 101 1 to 50 86 94 102 102 114 114 51 to 100 98 106 114 114 126 126 101 to 150 111 119 127 127 139 139 201 to 300 161 169 177 177 189 189 301 to 400 186 194 202 202 214 214 401 to 500 227 227 239 239 501 to 600 264 264 601 to 700 289 289 701 to 800 32 40 50 63 80 100 36 23 12.5 12.5 12.5 12.5 12.5 12.5 75 75 75 75 75 75 136 144 152 152 164 164 41
DO 41 30 12 18 S 204 4 5 M5 x 0.8 (Finger operating port) 20 9 6.45 6 MHW2-20D1 Right angle finger type 31 15 10 11 14 5 28 16 41 4-M4 x 0.7 (Thread for mounting attachment) 12-10-19 19 Series MHW2 Dimensions MHW2-25D Flat finger type (Standard) 24 2-M6 x 1 thread depth 10 (Mounting hole) 20 4-M6 x 1 thread depth 12 (Mounting thread) Bottom through hole dia. 5.1 (Mounting hole) 69 51 40 27
Weight (g) Model End boss type (Symbol) M K E W MHZ2-10 65 66 65 64 MHZ2-16 147 148 148 147 MHZ2-20 277 277 277 277 MHZ2-25 494 496 495 495 12-2-41 41 Parallel Style Air Gripper With Dust Cover Series MHZJ2 Size: 6, 10, 16, 20, 25 How to Order MHZJ2 16 F9BW D Number of auto switches Number of fingers Nil S 2 pcs. 1 pc. 2 2 fingers Bore size Auto switch Action 6 10 16 20 25 6 mm 10 mm 16 mm