Model: 3 (SGC300), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 05 (0 to 0.5 MPa), Thread: Rc, Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 5 (24 VDC), Electrical Entry: T (Conduit Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Bracket Mounting Position: B2 (Bracket on the Right
Model: 3 (SGC300), Valve Type: 1 (Normally Closed), Seal Material: B (FKM), Pressure Range: 05 (0 to 0.5 MPa), Thread: Rc, Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 1 (100 VAC 50/60 Hz), Electrical Entry: T (Conduit Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Bracket Mounting Position: B1 (Bracket
Model: 3 (SGC300), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 05 (0 to 0.5 MPa), Thread: Rc, Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 5 (24 VDC), Electrical Entry: W (M12 Connector, 4-pin Type), Surge Suppressor: Z (With Light and Surge Voltage Suppressor)
Symbol 2 3 4 Metric sizes 04 06 08 10 12 4 x 3 6 x 4 8 x 6 10 x 8 12 x 10 Symbol B A Inch sizes Basic size With reducer 03 05 07 11 13 1/8" x 0.086" 3/16" x 1/8" 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" Note 1) Applicable fittings: LQ2 Note 2) For details of the applicable tubing sizes, refer to page 945.
Auto switches with load voltage less than 20 V cannot be used. Because there is no current leakage, the load voltage will not increase when turned OFF. However, depending on the number of auto switches in the ON state, the indicator lights may sometimes grow dim or not light up, due to the dispersion and reduction of the current flowing to the auto switches.
When grounding a shield, remove the sheath and use a metal U-crip or P-crip. 20 Directional Control Driver for Electric Cylinder Series LC3F2 Applicable Cylinder Table Cylinder part no.
Silencer Metal Case Type Series 25 How to Order Exhaust in only one direction Prevents scattering of mist and noise. 25 10 002 Port size Thread type Body size 002 003 004 006 010 1/4 3/8 1/2 3/4 1 R NPT Nil N 04 05 06 07 08 10 11 Specifications Max. operating pressure (1) Fluid Compressed air 1.0 MPa 19 dB (A) JIS Symbol Noise reduction Ambient and fluid temperature 5 to 60C (2) Note 1) It
ARM 2500 05 A 02 G1 Made to Order Optimal for central pressure control. Nil None With backflow function Regulator for manifold X216 Easily set up using the new knob. Also has a One-touch lock system.
Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.
Model: 10-SY3000, Stations: 05, SUP/EXH Block Assembly: Both Sides, 2 to 20 Stations, A, B Port Size: One-touch Fitting for ΓΈ6
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 05 (5 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 05 (5 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 05 (5 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.