A + Stroke 20Data Common Dimensions: MVGPM/MVGPL B C DA FA FB G GA GB H HA IA IB Extension locking Retraction locking IC Standard stroke (mm) Bore size (mm) ID IE IF IG IH J K L 20 25 32 9.5 10 9 79.5 10 10 12 32.5 8.5 9 9 26.5 36 40 49 M5 x 0.8 6.5 7 8 21.2 18 21 24 10 12 16 36 42 48 10.5 37 83 93 112 6 7.5 9 24 30 34 M5 M5 M6 32 18 21 24 3 20, 30, 40, 50, 75, 100, 125 150, 175, 200,
): PAF3410S-X68 1S13 1S19 152 2 x M5 x 0.8 Thread depth 9 139 (40) 11 133 114 95 19 63 121 4 x 7 Reset button Bottom view of body Foot (Option) With nut (with LQ3 fittings) PAF3410-S-3S13--X68 16 FLUID OUT With nut Air operated reset port Rc, NPT, G 1/8" (102) AIR SUP Rc, NPT, G 1/4" 119 106 14 13 97 77 43 Silencer: AN20-02 (Option) Foot (Option) FLUID IN With nut AIR EXH Rc, NPT, G 1/4"
A + Stroke 20Data Common Dimensions: MVGPM/MVGPL B C DA FA FB G GA GB H HA IA IB Extension locking Retraction locking IC Standard stroke (mm) Bore size (mm) ID IE IF IG IH J K L 20 25 32 9.5 10 9 79.5 10 10 12 32.5 8.5 9 9 26.5 36 40 49 M5 x 0.8 6.5 7 8 21.2 18 21 24 10 12 16 36 42 48 10.5 37 83 93 112 6 7.5 9 24 30 34 M5 M5 M6 32 18 21 24 3 20, 30, 40, 50, 75, 100, 125 150, 175, 200,
x 0.8 x 16 M5 x 0.8 x 20 M5 x 0.8 x 25 ( ): Denotes the values of D-A44C Dimensions (mm) D-A3C D-A44C 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland G 1/2 G 1/2 4 x Z 4 x Z (Applicable cable O.D. 6.8 to 9.6) (Applicable cable O.D. 6.8 to 11.5) Hexagon socket head cap bolt Hexagon socket head cap bolt Indicator
x 1.25 10 8 28 25.5 Q R T V Y N O P Bore size (mm) 12 20 M4 x 0.7 M5 x 0.8 47 7 53.5 22 7 5.5 M6 x 1 M5 x 0.8 50 15 62.5 36 5 For rod end nut accessory bracket, refer to page 658.
Material Description Pilot valve assembly AXT627-42-1 (M5 x 50) AXT627-10-1 VFR51 AXT627-10-1 VFR52 AXT627-42-1 (M5 x 50) AXT627-10-1 VFR53/54/55 8 NBR Hexagon socket head screw Gasket 9 10 AXT627-42-1 (M5 x 50) Refer to How to Order Pilot Valve Assembly on page 1298.
With front lockR (mm) Bore size (mm) W P WA WB WH 20 M5 x 0.8 16 15 (16) 23 30 25 M5 x 0.8 16 15 (16) 25 30 32 Rc1/8 16 15 (16) 28.5 25 40 Rc1/8 16 15 (16) 33 20 50 Rc1/4 18 17 (18) 40.5 20 63 Rc1/4 18 17 (18) 47.5 20 80 Rc3/8 22 22 60.5 20 100 Rc1/2 22 22 71 20 Dimensions inside ( ) are for long strokes.
fitting [1(P) release pressure port] Applicable tubing O.D: 8, 5/16" One-touch fitting (X: External pilot port) Applicable tubing O.D: 4, 5/32" 20.5 6.2 One-touch fitting [PE: Pilot EXH port] Applicable tubing O.D: 4, 5/32" 46.5 (with plug) F1 release pressure side Filter body assembly Connector entry upward M5 x 0.8 (with plug) 43.5 [PS pressure detection port] F2 vacuum pressure side Filter
D-F9N, F9P, F9B 11.9 16 78.2 85 D-F9NV, F9PV, F9BV 10.9 15 79.2 86 D-F9NW, F9PW, F9BW 11.9 16 78.2 85 D-F9NWV, F9PWV, F9BWV Switch operating position (OFF) 10.9 15 79.2 86 D-F9BA 11.9 16 Note) This varies according to the operating environment, and cannot be guaranteed.
VQC2000 VVQ1000-50A-C3 VVQ1000-50A-C4 VVQ1000-50A-C6 VVQ1000-50A-M5 VVQ1000-50A-N1 VVQ1000-50A-N3 VVQ1000-50A-N7 VVQ1000-51A-C4 VVQ1000-51A-C6 VVQ1000-51A-C8 VVQ1000-51A-N3 VVQ1000-51A-N7 VVQ1000-51A-N9 3.2 4 6 8 M5 1/8" 5/32" 1/4" 5/16" With miswiring prevention mechanism (stop diode) Note) A-side energized: Light (orange) ON B-side energized: Light (green) ON With surge absorbing mechanism
Front view Mounting holes on the top Bottom view T slots on the bottom T slots on the bottom Mounting holes on the top Model Nominal of actuator Thread size Model Nominal of actuator Thread size Effective length 16 M3 16 M3 4 to 5mm E-MY2C E-MY2H E-MY2C E-MY2H 25 M5 25 M5 6 to 8mm 16 M5 16 M4 6 to 7mm E-MY2HT E-MY2HT 25 M8 25 M6 8 to 10mm If T slots on the bottom is used for installation,
Selection Example Operating conditions W Workpiece mass: 16 [kg] Speed: 300 [mm/s] 40 Acceleration/Deceleration: 5000 [mm/s2] 35 Stroke: 300 [mm] Lead 3: LEY25C 30 Workpiece mounting condition: Vertical upward downward transfer Work load [kg] 25 20 Lead 6: LEY25B 15 Step 1 Check the work loadspeed.
Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.
1/4,1/8 (Breathing port) M5 x 0.8 16.5 20.4 Body ported: VPA342VA B 20.4 16.5 NO NC 2(A) 26.5 21.5 2.25 Switch mark 26.7 23.2 Bracket (Mounting hole) 23.2 (PA port) Rc 1/8 (Mounting groove for M5 thread) 2-R2.7 PA 5 36 35 35 3.5 21.5 31 17.5 1.6 15 26.7 45 9 54.5 65.6 54.4 1(P) 3(R) 4.5 (Piping port) Rc 1/4,1/8 (Breathing port) M5 x 0.8 16.5 20.4 5-5-15 4 Series VPA300/500/700 Dimensions
AMR ITV IC Dimensions Model (Standard) VBA G15 Pressure range Note) Connection thread Indication unit Model VE (MPa) MPa R 1/8, M5 (Female thread) 0 to 1.0 0 to 1.0 G15-10-01 VY1 1 16 R M5 x 0.8 x 5 MPa G27-10-R1 Note) Do not apply more excessive pressure than max. pressure display. It will be a cause of malfunction. G Other versions of this unit can be made on a made-to-order basis.
Port size VQC1000/2000 VQC4000 --C8 Port size VQC2000 VQC1000 Symbol C3 C4 C6 C8 C10 C12 N1 N3 N7 N9 N11 M5 02 03 B C0 VVQC 1 000-2A-1 For 3.2 One-touch fitting For 4 One-touch fitting For 6 For 8 For 10 For 12 For 1/8" For 5/32" For 1/4" For 5/16" For 3/8" For M5 thread Rc 1/4" Rc 3/8" Rc 1/4" bottom ported Without One-touch fitting Option Series Nil R Centralized exhaust External pilot
inch (Maintenance space 100mm or more) IDG10, 20 IDG10H, 20H With fittings for purge air discharge (Option: P) (H) Purge air E A Port size L C 41 2.3 Purge air discharge tubing port for dew point indicator Applicable tube O.D.: 8 5/16 inch 14 7 14 16 23 IN OUT Bracket (Accessory: B) (G) B D Purge air discharge tubing port for dehumidification Applicable tube O.D.: J (NPT thread: K inch)
10 stations) 16 16 stations Both sides (2 to 16 stations) Pilot specifications Note 1) Double wiring specifications: Single, double, 3 position and 4 position solenoid valves can be used at all of the manifold stations.
(a) Direct Mounting with four M5 screws Mounting screw (M5) 4pcs. (prepared by customer) (b) DIN rail mounting The figure on the right shows how to mount the DIN rail mounting brackets. Secure the DIN rail mounting bracket using the mounting screws (M5 x 8) 2 places on one side (4 places on both Mounting screw M5X8 sides).
Item Decimal Comm Format "Data-SINT" Input 16 [bytes] Output 16 [bytes] Configuration 0 [bytes] (4)(5) (1) 16 (2) 16 (3) -41No. JXC-OMU0026 6.