SMC's new AF modular style air filter combines the element and bowl in one piece, making element replacement easy. There is a maximum 46% reduction in size, reducing required maintenance space. The AF bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360° monitoring. The modular design of the AF allows connection with other SMC air preparation equipment.
SMC's new AF modular style air filter combines the element and bowl in one piece, making element replacement easy. There is a maximum 46% reduction in size, reducing required maintenance space. The AF bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360° monitoring. The modular design of the AF allows connection with other SMC air preparation equipment.
SMC's new AF modular style air filter combines the element and bowl in one piece, making element replacement easy. There is a maximum 46% reduction in size, reducing required maintenance space. The AF bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360° monitoring. The modular design of the AF allows connection with other SMC air preparation equipment.
SMC's new AF modular style air filter combines the element and bowl in one piece, making element replacement easy. There is a maximum 46% reduction in size, reducing required maintenance space. The AF bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360° monitoring. The modular design of the AF allows connection with other SMC air preparation equipment.
Large Flow Air Filter Series AF800/900 Standard Specifications AF900 AF800 Model AC 1 4 1 2 Port size AV 1 2 1 1.5MPa Proof pressure AU 1.0MPa Max. operating pressure Ambient and fluid temperature AF 5 to 60C (No freezing) Filtration Standard: 5 m Optional: 2, 10, 20, 40, 70, 100 m AR Polycarbonate (standard) Bowl material IR Bowl capacity (cm3) 180cm3 Weight (kg) 5.45kg 3.15kg VEX Bowl guard
AF800 AF900 Model AV 1 4 1 2 Port size 1 2 1 AU 1.5 MPa Proof pressure 1.0 MPa Maximum operating pressure AF Ambient and fluid temperature 5 to 60C (No freezing) AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Standard specifications: 5 m Option: 2, 10, 20, 40,
IS400-1 (1S-1) IS400-2 (1S-2) Model Port size B C D E F G H I J A , 1 4 1 2 1 1 AL800-12 to 14-1 AL900-20-1 431 (481) 437 (487) 3-M5 x 0.8 x depth 6 3-M5 x 0.8 x depth 6 230 230 ( ): With float switch 117 117 60 60 100 100 2 59 63 166 162 73 73 14-13-5
1 MR Unit (Regulator with Mist Separator) Series AMR3000 to 6000 Standard Specifications AMR3000 AMR4000 AMR5000 AMR6000 Model F.R.L. 1 1 4, 3 8 1 4, 3 8, 1 2 1 2, 3 4 3 4, Port size Air Fluid AV 1.5 MPa Proof pressure AU 1.0 MPa Max. operating pressure 0.05 to 0.85 MPa Setting pressure range AF 5 to 60C (No freezing) Ambient and fluid temperature Relieving type Construction AR Courtesy of
Bleed port AU AF Handle locking screw AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Component Parts Caution No.
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: JT (J + T)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: W (SI Unit Only)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: TU (T+U)
Cooling Capacity: 012 [1000/1200, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: T (High-pressure Pump Mounted)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: UY (U+Y)
Cooling Capacity: 050 [4600/5100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: U (Conforming to UL Standards)
Cooling Capacity: 012 [1000/1200, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: MTU (M+T+U)
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: T (High-pressure Pump Mounted)
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: TY (T+Y)