Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: V (Panel Mount Adapter for w/Flow Adjustment Valve)

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: S (Bracket for w/Flow Adjustment Valve)

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: S (Bracket for w/Flow Adjustment Valve)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: K (Operation Manual

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)