SMC Corporation of America
Elite Part Number Search
Search Results "VZM450-F01-34B-F"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CA, IFW/PFW 1/8INCH PT VERSION, 0.4556 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CA, IFW/PFW 1/8INCH PT VERSION, 0.44092 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PROCESS PUMP, AIR OPERATED, VALVE, PB PROCESS PUMPS, DX, PB BODY PORT 1/8, 0.49604 lb

SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.  The series is incredibly compact and lightweight compared to existing flow sensors.  The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

Please contact us for the latest version.sales@ocaire.com, F/R COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, CA, AC MASS PRO 1/8 MODULAR (PT), 1.50036 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CA, IFW/PFW 1/8INCH PT VERSION, .60627 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM75092%8%1.0 to 50.0 l/min1.0 to 52.5 l/min0 to 52.5 l/min5.00 V20.0 mA

The VZM series is a 5 port mechanical valve. It is compact in design with a large flow capacity (VZM400 Cv 0.55, VZM500 Cv 0.6). The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5° to 60°C (no freezing), Effective area (Cv): 0.55, Port size

The VZM series is a 5 port mechanical valve. It is compact in design with a large flow capacity (VZM400 Cv 0.55, VZM500 Cv 0.6). The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5° to 60°C (no freezing), Effective area (Cv): 0.55, Port size

The VZM series is a 5 port mechanical valve. It is compact in design with a large flow capacity (VZM400 Cv 0.55, VZM500 Cv 0.6). The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5° to 60°C (no freezing), Effective area (Cv): 0.55, Port size

The VZM series is a 5 port mechanical valve. It is compact in design with a large flow capacity (VZM400 Cv 0.55, VZM500 Cv 0.6). The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5° to 60°C (no freezing), Effective area (Cv): 0.55, Port size

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/o Flow Adjustment Valve

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow Adjustment

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -