V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PFMC7501 5 L/min 500 L/min PFMC7102 10 L/min 1000 L/min PFMC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.
V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PF2MC7501 5 L/min 500 L/min PF2MC7102 10 L/min 1000 L/min PF2MC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.
-1 10 1 IDX-OM-W014 10 M 10-2 ADM200 IDU3E6E-10-M IDU3E6E-20-M IDF-S0087 IDF-S0090 1.0MPa 1 1 2 / AC100V(50/60Hz) AC200V(50/60Hz) 4W IDU Series 10-2 10 2 IDX-OM-W014 10 M 10-3 Rc1/2 32 25 1) 2830Nm 30 (5) (17)(30) 2 2 Rc1/2 10-4 1-1 IDU Series 10-3 10 3 IDX-OM-W014 11 R 11 R 11-1 11-2 1 AC100V AC200V, AC230V INOUT IDU3E/4E/6E-10-R IDU3E/4E/6E-20/23-R (A)
11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20 30 30 12.5 16.5 23.5 23.5 Bracket Combinations Bracket combination table -Refer to table together with combination drawings.
Refer to the table for each pressure specification (page 110) Display/set pressure range Display/min. setting unit Power supply Used as switch output device 12 to 24 VDC (10%), and voltage ripple (p-p) 10% at max. voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Electric spec. Power supply voltage 12 to 24 VDC (10%), and ripple (p-p) 10% at max.
VZ Control Unit Specifications Control Unit/Option VF Air filter (With auto-drain/With manual drain) Filtration degree Regulator MP2-1 (With control unit/Filter regulator) VVZS2000-15A (With pressure switch) VVZS2000-24A-10(Release valve) 10 m VFR Blanking plate Plug-in type Set pressure (Outlet pressure) Pressure switch Set pressure range: OFF Differential pressure Contact Max. switch capacity
ZQ-OM01301-A 9 Clamping rod assembly (2 pcs. are included in one set) ZQ1-SR1-04-A (1) Number of stations 01 1 stations (1) 02 2 stations 08 8 stations 10 Sound absorbing material (for manifold ) (2 pcs. are included in one set) ZQ1-SE2-A 11 Silencer block assembly (2 pcs. are included in one set) ZQ1-SC1-A 12 Ejector body gasket for manifold (10 pcs. are included in one set) ZQ-3-005-10AS
Auto Switch l1 50 Safety distance (mm) 40 Operational range 30 l1 20 l1 Dangerous range 10 0 5000 10 15000 20 Welding current (A) l2 50 40 Safety distance (mm) 30 l2 l2 Operational range 20 10 0 5000 10 15000 20 Welding current (A) 1340
IN side, OUT side 4 10 22 20 22 30 30 50 30 75 39 75 39 Series ZFB Model ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 6 6 8 8 10 Metric size 3/16" 20 22 20 22 30 30 75 40 100 62 ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 1/4" 1/4" Inch size (2) 3/8" 1/2" Specifications Fluid Air/Nitrogen Negative pressure 0.5MPa 0 to 60C (Non-freezing) 30m 0.15MPa Nylon/Soft Nylon/Polyurethane
50 Safety distance (mm) 40 Operational range 30 l1 20 l1 Dangerous range 10 0 5000 10 15000 20 Welding current (A) l2 50 Safety distance (mm) 40 30 l2 l2 Operational range 20 10 0 5000 10 15000 20 Welding current (A) 32 SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE SPAIN/PORTUGAL SMC Espaa, S.A.
4 88 116 5 107 135 6 126 154 7 145 173 8 164 192 9 183 211 10 202 230 Symbol L1 L2 4-15-17 18 Series VZ200/400 Precaution 1 Be sure to read before handling.
5 2.86 20 10 5 Parameter *1,*2 Para.
(mm) 02 04 2 4 Nil -X19 With lock ring Without lock ring (10 or larger) 1 2 10 to 16 20 to 32 ZX 06 6 3 40, 50 ZR 08 8 Material 10 10 ZM N S NBR Silicon rubber 13 13 16 16 Pad type U Urethane rubber 20 20 ZH F Fluoro rubber 25 25 U C Flat Flat with ribs GN Conductive NBR (2 to 16) 32 32 ZU GS Conductive silicon rubber (2 to 16) 40 40 D Deep 20 or large are manufactured upon receipt of order
Specification for Option L 10 . 1 Safety instructions . 10 1 10 . 2 Specifications . 10 1 10 . 3 Installation of heavy duty auto drain . 10 2 10 . 4 Maintenance . 10 2 Chapter 11 Specification for Option M 11 . 1 Safety instructions . 11 1 11 . 2 Specifications . 11 1 11 . 3 Installation of motor type auto drain . 11 2 11 . 4 Electric wiring diagram . 11 2 Chapter 12 Specification for Option
to 10 (832) Integrated time setting; -10 to 10 (833) Differentiation time setting; -10 to 10 Table 12 Amount of change when set value is increased/ decreased by 1 Set value is 0 or more Set value is less than 0 Prop. gain 10% 10% Integ. time 50% 10% Deffer. time 10% 10% 8: When automation calibration is performed, PID constant is automatically set.
For valve weight, refer to page 2-3-10.
( ) 10.2 1.6MPaADH4000-04 IDF15E1-10-L IDF15E1-20-L N.O. () ) 0.051.6MPa 400cc/min (0.7MPa ) ) 50L/min(ANR) 10 1 10.L 10.3 Rc1/2 32 25 1) 2830Nm 30 (5) (22)(27) () () () 2) 10.4 10 2 11.M M 11 11.1 ( ) 11.2 ADM200 IDF15E1-10-M IDF15E1-20-M IDF-S0087 IDF-S0090 1.0MPa 1 1 2 / AC100V(50/60Hz) AC200V(50/60Hz) 4W 11 1 11.M 11.3 Rc1/2 32 25 1) 2830Nm 30 (5)
knuckle joint Press-fit spring pin 3 x 22 L 10 +0.022 H8 0 13 Press-fit spring pin 3 x 22 L Shaft: 10 Hole: 10 13 0.040 d9 0.076 +0.022 H8 0 24 24 C7 C7 30 +0.5 +0.2 12 0.1 0.3 12 41.2 26 24 18 36 36 D48 48 Please contact SMC for details of the CKGA32 series.
n x 10 M5 both sides common air pressure supply (P) port P P Note 1) The above dimensions are for ZZA103-00.
Option Specification R 10 1 Safety instructions . 10 1 10 2 Specifications of GFCI . 10 1 10 3 How to connect the power supply . 10 2 10 4 Cautions for handling the GFCI . 10 2 10 5 Electrical Circuit . 10 2 Chapter 11 Specification for Option T 11 1 Safety instructions . 11 1 11 2 Specifications . 11 1 11 3 Remote operation . 11 1 11 4 How to connect the power supply and signal cable .