SMC Corporation of America
Elite Part Number Search
Search Results "MBBD32TN-125-RN"

Content Bore size (mm) CHA40-PS 40 50 63 80 100 125 160 CHA40-PS CHA50-PS CHA63-PS CHA80-PS CHA100-PS CHA125-PS CHA160-PS !7 !8 !9 @0 @1 @2 23 Seal kit consists of items !7 through @2 and can be ordered using the seal kit number for each bore size. Cushion seal CHA50-PS Wiper ring NBR CHA63-PS Set of left nos. !7, !8, !

Tie-rod Type Hydraulic Cylinder/Double Acting, Double Rod Series CHAW 40, 50, 63, 80 100, 125, 160 Construction Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !6 !7 @0 @1 !8 @2 !

Therefore repair at SMC is recommended. 56 %7 Guide gasket NBR Tube gasket NBR Replacement Parts: Lock Unit CNS D 125 TN UA Unit assembly Bore size (mm) Thread type Locking direction (Both directions) Nil TN NPT TF G Rc 160

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, GUIDE, END LOCK, ACTUATOR, MGG GUIDED CYLINDER, IB, 25MM MGG BALL BEARING, .00000 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)MGGGuide cylinderMGGDouble actingExcept with shock absorber, with rubber cushion--8--

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 40MM CBG1 DOUBLE-ACTING, ACTUATOR, CBG1 END LOCK CYLINDER, MD, 40MM CBG1 DOUBLE-ACTING, 2.42508 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 40MM CBG1 DOUBLE-ACTING, ACTUATOR, CBG1 END LOCK CYLINDER, MD, 40MM CBG1 DOUBLE-ACTING, 2.20462 lb

The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap

Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. End lock cylinder, CBG1, Double acting, single rod, 7 mounting styles available, Bore sizes *: 20, 25, 32,

Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. End lock cylinder, CBG1, Double acting, single rod, 7 mounting styles available, Bore sizes *: 20, 25, 32,

ms 3F.S.() LED 3 7 2 (/) OUT1ON OUT2ON DC24 V10 55 mA IP40 050 () 050 -1060 () 3585R.H.() AC1000 V 1 50 M (DC500 V ) CE(EMC ROHS )ULCSA 110L/min10009.99 L/min 2100L/min100099.9 L/min 3 ()10024 551005009.5 221002003.8 420 1 atm() 0 1 atm() -55No.PF-OMJ0005CN-I 01 02 N01 N02 F01 F02 C4 C6 C8 N7 4 8 () Rc Rc NPT 1/8 NPT 1/4 G G 6 1/4 (5/32") (5/16") 1/8 1/4 1/8 1/4 95 g 125

Max. 2s 2s 1s 1s Min. 0.5s 0.5s 0.2s 0.2s 0.1s 0.1s 0.05s 0.05s 0.02s 0.02s 0.01s 0.01s 6000 100 125 200 300 400 500 700 1000 1500 2000 30004000 10 100 125 200 300 400 500 600700 1000 1500 2000 3000 4000 600 5000 7000 Current (% for breaker capacity) Current (% for breaker capacity) For HRS100-A/W-20-B For HRS150-A/W-20-B HRS100-A/W-40, HRS150-A/W-40 4h 2h 1h 30min 20min 14min 10min 6min

(page 139) -140No.PF-OMA1007-B Standby regulator type NO specification AMS20/30/40/60B-R/N/F#D Part number P A B C D E J M L AMS20B-#D 1/8 1/4 301.8 214.7 85.1 66.8 25.6 46.2 24 40.1 AMS30B-#D 1/4 3/8 348.3 214.7 102.1 86.5 29.1 46.2 30 40.1 AMS40B-#D 3/8 1/2 395.8 214.9 119.4 91.5 32.6 46.2 36 40.1 AMS60B-#D 3/4 1 491.8 214.8 118 125 42.1 46.2 46 40.1 : Dimension D is the dimension

A /B 90 0.1mm/ 2-1. 2-2 F.G CE1-R** CE1 CEU5 OUT1OUT5 RS-232C OUT1OUT20(bank ) (31 ) 221 () B L F G D 0.5 L 3 Z 12 12mm 20 20mm 32 32mm 40 40mm 50 50mm 63 63mm 4063 N R H (mm) (mm) (mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 20 32 40 50 63 222 A90 D-A90 M9N D-M9N M9NW D-M9NW A93 D-A93 M9P D-M9P M9PW D-M9PW A96 D-A96 M9B D-M9B M9BW D-M9BW A90V D-A90V M9NV D-M9NV

Precautions:Controller and its peripheral devices Electric actuators/Common precautions 124 9.1 Design and selection . 124 9.2 Handling . 124 9.3 Installation . 125 9.4 Wiring of cables/Common precautions . 126 9.5 Power supply . 126 9.6 Grounding . 126 9.7 Maintenace . 127 10.

Round pliers Nominal: 125 3 Remove the valve guide assembly. Remove it while lifting the circumferential part with a precision screwdriver. Precision screwdriver (-) 4 Remove the valve spring. 5 Remove the valve assembly. Assembly 6 After replacing the removed components with new components, place them into the regulator.

Size Rated Rated Rated (to be onnected of leak current voltage current to the user's current equipment) Plug with ground HRSE012-A-10 3 cores x terminal (JIS C8303 Plug for the eceptacle for 15A and 125 V with dipole grounding electrodes) HRSE012-A-10-T 14AWG Shared 15mA 1-phase HRSE018-A-10 (3 cores x 2.0mm2) with 100 100V AC 15A 15A or V and 200 V (50/60Hz) 30mA (including HRSE018-A-10-

The cylinder section does not have a water resistant enclosure. 3-3 Allowable Kinetic Energy 3-3-1 Allowable Kinetic Energy (J) Bore size(mm) 12 20 32 40 50 63 Allowable Kinetic EnergyE 0.022 0.055 0.15 0.26 0.46 0.77 3-3-2 Mass of Cylinder Movable Parts (g) Cylinder stroke (mm) Bore size(mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 28 33 38 43 48 53 20 70 84 98 112 126 140 154 168

Heavy load Standard load Medium load Light load 1 10 50 100 200 1 0.25 0.49 0.98 1.96 2 20 2 0.49 75 200 400 0.74 1.47 2.94 3 30 3 0.74 100 300 600 0.98 1.96 3.92 4 40 125 400 800 4 0.98 1.23 2.45 4.90 5 50 5 1.23 150 500 1000 1.47 2.94 5.88 6 75 200 600 1200 6 1.47 1.96 3.92 7.84 7 100 250 700 1400 7 1.72 2.45 4.90 9.80 8 300 300 800 1600 8 1.96 2.94 5.88 11.76 9 500 500 900 1800 9 2.21

Tightening torque Nominal 1.40.1Nm 125 or 150 10. Mount the bowl assembly. AL20-A Referential tightening torque Hold the bowl assembly by hand and rotate clockwise. Do not use tool for mounting because the bowl may be damaged. See check item for referential tightening torque. 2.1 Nm Disassembly 1. Remove the bowl assembly.

.: GR-S-010 (10 g) 72 Compact Cylinder/Large Bore Size: Double Acting, Single Rod Series CQ2 Replacement Procedure is 125, 140, 160 180, 200 P.290 Construction Standard Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !2 !3 !