-X 20K = 1 Table (1) Maximum Allowable Kinetic Energy: Emax (J) 1.0 Allowable Load Weight Coefficient: End plate mounting Data 0.7 Model Allowable kinetic energy Rubber bumper 0.027 0.055 0.11 0.16 0.5 W MXF8 MXF12 MXF16 MXF20 0.4 0.3 K = 0.6 0.2 Table (3) Moment Center Position Distance Compensation Amount: An (mm) Table (2) Maximum Allowable Load Weight: Wmax (kg) 50 100 200 300 500 700


Replaceable pilot valve: SY, SYJ, VF, VFR, VFS, VP4□50/4□70, VP300/500/700, VG342, and VP3145/3165/3185 series
Replaceable solenoid assembly: VT317 series

The pilot valve or solenoid assembly of the following series is NOT replaceable.

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/300, 1200/500, 1800/500, 2400/700, 3000/700, 5100/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/200, 1200/500, 1800/500, 2400/700, 3000/700, 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/300, 1200/500, 1800/500, 2400/700, 3000/700, 5100/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/200, 1200/500, 1800/500, 2400/700, 3000/700, 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

without control unit and bracket mounted, Others 30 m/s2, whichever is smaller for 2 hours in X, Y, Z direction each (De-energized) Vibration resistance Without control unit and bracket mounted: 980 m/s2, Others: 150 m/s2 in X, Y and Z direction, 3 times each (De-energized) Nil: Rc 1/8, N type: NPT 1/8, F type: G 1/8 4-core, oil resistant, cable (0.64 mm2) with M12, 4-pin pre-wired connector

Note 3) For detailed specifications other than the above, refer to the separate technical operation manual that can be downloaded from SMCs website (http://www.smcworld.com/). 10 to 150 Hz with a 0.035 mm amplitude or 4.9 m/s2 in each X, Y, Z direction for 2 hrs (De-energized) 147 m/s2 in each X, Y, Z direction, 3 times (De-energized) Standard CE marking, UL (CSA) Communication connector

Compatible Compatible Compatible ORIG direction Set in units of 1/s Speed during return to origin position Set in units of 1 mm/s ORIG speed No setting required Set in units of 1/s2 Acceleration during return to origin position Set in units of 1 mm/s ORIG ACC Continuous operation at the set speed can be tested while the switch is being pressed.

External terminals (including the FE terminal) and enclosure screws Insulation resistance 10 M or more 500 VDC External terminals (including the FE terminal) and enclosure screws EN61131-2 compliant 5f<8.4 Hz 3.5 mm Vibration resistance 8.4f<150 Hz 9.8 m/s2 Impact resistance EN61131-2 compliant, 147 m/s2, 11 ms Mounting Through hole for M4 screw (2 pcs.)

ZB-OM00201-B Specifications General Specifications Ambient -5 to 50oC (No condensation) temperature range Fluid Air, inert gas Vibration 30m/s2 (Without pressures sensor/vacuum pressure switch, With pressure sensor) resistance Note 1) 20m/s2 (With switch) Impact 150m/s2 (Without pressures sensor/vacuum pressure switch, With pressure sensor) resistance Note 2) 100m/s2 (With switch) Note 1)

Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

Mount switches in locations where there is no vibration greater than 98 m/s2, or no impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.

Do not drop, bump, or apply excessive impact (PSE540: 980 m/s2, PSE560: 500 m/s2) while handling. Although the body of the sensor may not be damaged, the inside of the sensor could be damaged and lead to malfunction. 2. The tensile strength of the cord is 50 N. Applying a greater pulling force to it can cause malfunction.

(STO switch) S2: Start switch (STO release switch) S3: On switch S4: Off switch KM1: Magnetic contactor K3: Safety relay EMG: Emergency stop switch CN3 EM1 or EM2 M Servo motor Note.

Mount the switch in a location where there is no vibration greater than 98 m/s2, or no impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.

Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

The operating time for D-J51 is 2 ms or less and for D-P3DW/P4DW are 40 ms or less. 4) 980 m/s2 for the trimmer type sensor section, 98 m/s2 for the amplifier section.

Movement Load : Angular acceleration F: Pressing force (N) T f = F x l (Nm) . 2 = (rad/s 2) Load Static torque calculation t 2 g = 9.8 m/s2 Ts = F x l (Nm) l : Rotation angle (rad) Lever t : Rotation time (S) Axis Rotary actuator Axis Allowable Load Application of the load on the axial direction is tolerated if no dynamic load is generated and the values are within what is shown in the