Model K VCKL0604-02F H KFN-06-X2 K VCKL0806-02F H KFN-08-X2 K VCKL1075-02F H L Union nut C3604BD + Ni plated 1 1 set unit KFN-10-X2 K VCKL1008-02F H K VCKL1209-02F H KFN-12-X2 K VCKL-02F H K VCKL0604-02F H KFS-06 K VCKL0806-02F H KFS-08 K VCKL1075-02F H M Sleeve Nylon 1 1 set unit KFS-10 K VCKL1008-02F H VNA VNB K VCKL1209-02F H KFS-12 SGC SGH N Gasket VCKK-4-1 Nylon 1 10 set unit VNC VNH
3 4.5 8 9.5 4 Section AA' 6-M3 x 0.5, depth 14 15 15 Mounting reference planes D B Q QL Without magnet and rail 8 2-M2 x 0.4, depth 3 3.15 2.5 (mm) G Model Z J H K L M QL Q S V W L MXP8-10 8 52 60 40 44 10 21 20 20 32 32 14 2-M2.5 x 0.45, depth 4 MXP8-20 50 20 82 36 36 41 20 74 65 90 50 20 8-8-27
K 20 m roll 100 m reel TUS1208 TUS0425 TUS0604 TUS0805 TUS1065 Model M Tubing O.D.
140 160 to 1400 50 47 145 145 205 1/2 3/8 115 36 90 63 35 14 19 14 190 100 230 16 155 to 1400 50 47 161 160 245 1/2 3/8 128 36 90 63 35 14 19 20 212 112 255 16 180 to 1400 56 53 182 180 290 1/2 3/8 144 40 90 63 43 14 19 20 236 118 275 18.5 215 (mm) Bore size (mm) GB GL GR J K KA M MM N P Q S T V VA H ZZ 125 140 160 23 25 30 M14 x 1.5 15 31 19 M30 x 1.5 35 1/2 85.5 303 87.5 20 23 110 432
(Example 2) 3 4.7 k External switch 16 4.7 k Operation mode request (Momentary) 4 4.7 k 24 VDC 6 Power supply usage example Contact output 1: Operation status [Operation ON] This products power supply usage example (Example 1) 19 Contact output 2: FLT [Fault alarm occurrence OFF] 7 24 VDC 1 Contact output 3: WRN [Warning alarm occurrence OFF] Circuit diagram 2 20 14 I n t e r n a l c i r
(Conforming to DIN) Clip Without indicator light AXT100-20-1 Rated voltage With indicator light 16.8 Voltage symbol Part no. AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 13.8 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V 1. It is able to change the cylinder port between side ported and top ported.
Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 40 30 20 20 30 40 50 3. Select the bore size and type of magnet holding force (types H, L) from Lo and Fn based on data K A .
Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 40 30 20 20 30 40 50 3. Select the bore size and type of magnet holding force (types H, L) from Lo and Fn based on data K A .
This allows for viable connections to take place without necessarily specifying whether the manifold station is double, single, or mixed wiring. 19 20 19 20 19 20 19 20 19 20 19 20 19 20 19 20 COM.
DC24V 2. 20 3. 4. 5. 6. 7. 8.
Dimensions (mm) A B C D E F G K L M N P Model IDFA100F IDFA125F Port size R2 670 460 335 107 700 1120 1276 267 1375 20 712 752 R2 1/2 700 655 350 78 935 IDFA150F E D B 10 note) A G F C N M L K Note) In addition to the overall length of the body, the filter mounting part (bracket) projects 10 mm.
Effective area of the built-in back pressure check valve type is reduced approximately 20%. None Built-in Nil K Internal pilot External pilot Nil R External pilot specification is not available for 4 position dual 3 port valves.
16 47 125 15 340 1/2 77 140 12 20 16 55 160 20 375 3/4 94 159 12 24 20 60 109 Tie-rod Type Low Pressure Hydraulic Cylinder Double Acting/Double Rod Series CHAW Front flange type: CHAWF Width across flats G 4-FD 4-J 2-Rc P T T V V Cushion adjustment screw MM Width across flats G GA Air release GA M MM R (max.) d d W W D E E D FY B C MA a a FT MA B F NA NA F K A A K H + Stroke S + Stroke
20 2-M6 thread depth 11 2-M6 thread depth 11 15 15 35 18 15 2-M6 thread depth 11 2-M6 thread depth 11 20 20 A 17 17 40 A 20 20 15 45 60 25 45 60 A Applicable clamp cylinder A Applicable clamp cylinder Part no.
40 20 14 15.5 19 to 600 32 75 18 104.5 58.5 63 1/4 12 45 17.5 35 27 11 75 134.5 56.5 14 20 40 20 14 16.5 23 to 600 32 90 18 119.5 68 80 1/4 18 45 22 40 32 13 95 169 72 22 30 60 25 20 19 33 to 750 37 102 22 150 81 100 1/4 20 55 25 40 41 16 114 189 89 22 30 60 30 20 19 37.5 to 750 37 116 26 170 96 Bore size (mm) N S U V T P J MM GR GE GF K L Q RR H VA W Z ZZ 32 27 154 13 6.5 34 1/8 10.5 M6
flange) (CF flange) A B K S M J H G A (mm) Model A 123 170 183 217 256 B 48 66 79 100 117 C 1 2 2 3 3 D 40 55 75 87 114 Fn 95 110 Fd 70 114 Fc 26 41 52 70 83 G 41 63 68 72 98 H J K P.C.D L1 6-6.6 8-8.4 L2 XMD-25 XMD-40 XMD-50 XMD-63 XMD-80 50 65 70 88 90 16 20 20 20 20 7.5 15 17.5 19.5 26.5 P.C.D 58.7 P.C.D 92.1 C D XYD/In-line type G Fd C (K flange) J K H B S M 45 A Fn (KF flange
11 2-M6 thread depth 11 15 15 35 18 15 2-M6 thread depth 11 2-M6 thread depth 11 20 20 A 17 17 40 A 20 20 15 45 60 25 45 60 A Applicable clamp cylinder A Applicable clamp cylinder Part no.
M5 x 0.8 depth 5 M5 x 0.8 depth 5 (Vacuum port) DC DB DA High precision type 11-MSQAA 11-MSQAR Basic type 11-MSQBA 11-MSQBR DC DB DA (Vacuum port) HB HB HA HE (HD) (HD) 11.5 5.5 HC HC DD DD (mm) (mm) DA(h8) DB(h8) DC(h8) DD(h8) HA HB HC HD HE DA(h9) DB(h9) DC(h9) DD(h9) HB HC HD Size 10 20 30 50 Size 10 20 30 50 46 45 20 35 15.5 24 5 63 9.5 46 45 20 35 20 5 59 61 60 28 40 19.5 30 6 73 13.5
Load at lever end DNumber of teeth = a 20= m1 a12 1. Find the inertial moment B for the rotation of shaft (B). 3 + m2 a22 + K (Example) When shape of m2 is a sphere, refer to 7, and K = m2 2r2 2.