SMC Corporation of America
Elite Part Number Search
Search Results "EXA1-20-EN-ML"

Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 04 (1/2), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 06 (3/4), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: E (Push-turn Locking Type, Manual)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 06 (3/4), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: E (Push-turn Locking Type, Manual)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 06 (3/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: E (Push-turn Locking Type, Manual)

Body Size: 30, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type)

Body Size: 30, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)

Body Size: 30, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)

Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 06 (3/4), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)

(e.g., when the leakage rate is 20 L/min (ANR), the vacuum pressure of a ZH10□SA is -20 kPa and the vacuum pressure of a ZH10□LA is about -32 kPa, so the L type has a higher vacuum pressure)
The ZH series catalog can be found here.